Pelco EH3508 User Manual

®
EH3508 Series
Environmental Enclosure
Installation/Operation Manual
C1435M-A (11/96)
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • (559) 292-1981 • (800) 289-9100
FAX (800) 289-9150 or (559) 292-3827
Section Page
1.0 WARNINGS .......................................................................................................................................1
2.0 SCOPE...............................................................................................................................................2
3.0 DESCRIPTION...................................................................................................................................2
3.1 MODELS ....................................................................................................................................2
3.2 OPTIONS ...................................................................................................................................2
3.3 RECOMMENDED MOUNTS......................................................................................................2
3.4 RECOMMENDED CABLE SIZE/DISTANCE .............................................................................3
4.0 INSTALLATION..................................................................................................................................4
4.1 CAMERA/LENS INSTALLATION ...............................................................................................4
5.0 CARE AND MAINTENANCE..............................................................................................................5
6.0 EXPLODED ASSEMBLY DIAGRAM..................................................................................................6
7.0 MECHANICAL PARTS LIST ..............................................................................................................7
8.0 SPECIFICATIONS .............................................................................................................................8
9.0 WARRANTY AND RETURN INFORMATION ....................................................................................9
LIST OF ILLUSTRATIONS
Figure Page
1 Heater and Defroster Wiring Diagram ................................................................................................5
2 Heater Kit Installation .........................................................................................................................5
3 EH3508 Exploded Assembly Diagram ...............................................................................................6
4 EH3508 Dimension Drawing ..............................................................................................................8
REVISION HISTORY
Manual Number Date Comments
C1435M 6/95 Original version. C1435M-A 11/96 Changed height dimension, part numbers, and camera sled installa-
tion instructions per ECO #96-075.
®Pelco and the Pelco logo are registered trademarks of Pelco. ©Copyright 1996, Pelco. All rights reserved.
12 Pelco Manual C1435M-A (11/96)
ii
INSTALLATION/OPERATION MANUAL MODEL EH3508 SERIES ENVIRONMENTAL CAMERA ENCLOSURE
1.0 WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
The product may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present
within this unit.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
5. The installation method and materials should be capable of supporting four (4) times the weight of the enclosure, pan/tilt, camera and lens combination.
This symbol indicates that there are important operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
RISK OF ELECTRIC SHOCK.
CAUTION:
DO NOT OPEN.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
Pelco Manual C1435M-A (11/96) 1
2.0 SCOPE
3.2 OPTIONS
The information contained within this manual covers the EH3508 Series camera enclosures.
3.0 DESCRIPTION
The EH3508 Series are indoor/outdoor light-duty cam­era enclosures designed for use with various cameras on the market and will accommodate fixed focal length lenses or motorized zoom lenses, with or without auto­iris operation.
The lid of the enclosure is hinged in the front providing easy access during installation and when camera/lens adjustments are necessary. The camera sled itself (see Figure 3, Item 7) can serve as an elevation block. It can be removed, inverted and flipped, then reinstalled. All wiring and cabling is brought into the enclosure through adjustable glands at the bottom rear of the enclosure.
The rear link-lock latch can be used with a padlock of suitable size for applications requiring additional secu­rity.
Options for this series include heater, defroster and sun shroud.
3.1 MODELS
AFW3512 Anti-fogging window HK3512-1 Heater kit, thermostatically controlled,
120 VAC, 40 watts. Activates ON at 50°F (10°C); OFF at 80°F (26.67°C)
HK3512-2 Same as HK3512-1 except 24 VAC HK3512-3 Same as HK3512-1 except 230 VAC WD35-1 Window defroster kit, continuous duty,
3 watts, 120 VAC WD35-2 Same as WD35-1 except 24 VAC WD35-3 Same as WD35-1 except 230 VAC SS3508 Sun shroud for EH3508 Series only
3.3 RECOMMENDED MOUNTS
CM4400 Light duty ceiling mount with cable
feedthrough and manually adjustable
tilt table. Supports up to 15 lbs (6.75
kg). EM4400 Light duty wall mount with cable
feedthrough and manually adjustable
tilt table. Supports up to 15 lbs (6.75
kg).
EH3508 Enclosure, indoor/outdoor, 8.75" (22.22
cm) length.
EH3508-1 Same as EH3508 except unit is supplied
with 120 VAC heater and defroster.
EH3508-2 Same as EH3508 except unit is supplied
with 24 VAC heater and defroster.
EH3508-3 Same as EH3508 except unit is supplied
with 230 VAC heater and defroster.
2 Pelco Manual C1435M-A (11/96)