Pelco EH16 User Manual

INSTALLATION

EH16 Series IP-Enabled Enclosures

EH16 Enclosure with EM16 Mount
C3489M-B (3/14)

Contents

Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
User-Supplied Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Preparing the Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installing the Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installing the Camera in the Enclosure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installing the Sun Shroud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installing Lanyards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2 C3489M-B (3/14)

Important Safety Instructions

CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Clean only with dry cloth.
6. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
7. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
8. Only use attachments/accessories specified by the manufacturer.
9. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power­supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
10. Installation should be done only by qualified personnel and conform to all local codes.
11. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
12. Use only installation methods and materials capable of supporting four times the maximum specified load.
13. Use stainless steel hardware to fasten the mount to outdoor surfaces.
14. An all-pole main switch with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building.
15. A readily accessible disconnect device shall be incorporated in the building installation wiring.
CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other that contained in the operating instructions unless you are qualified to do so.
Only use replacement parts recommended by Pelco.
After replacement/repair of this unit’s electrical components, conduct a resistance measurement between the line and exposed parts to verify the exposed parts have not been connected to the line circuitry.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
C3489M-B (3/14) 3

Description

IP-enabled, indoor/outdoor, EH16 Series enclosures are designed for use with small- to medium-sized analog and IP cameras. They accommodate both fixed and variable focal length lenses (with or without auto iris operation). They can be mounted to a wall using either the Pelco EM16 (feedthrough wall mount) or EM1450 (non-feedthrough wall mount), or any light to medium duty mount.
The tethered, detachable enclosure lid provides easy access during installation and when camera and lens adjustments are necessary. Cabling for power and video is brought into the enclosure through two adjustable glands (PG9 and PG11) on the bottom of the enclosure, allowing for easy installation.
Factory-installed options include a heater and blower with a 24 VAC camera power supply and sun shroud. The enclosures can also be ordered from the factory with 24 VAC or IEEE802.3at power over ethernet (PoE) enclosure input voltage, 802.3af-compatible camera power, and appropriate heater and blower power.
Model Description
EH16 Basic enclosure, indoor/outdoor, included in all EH16 models. EH16MT Includes an additional EM16 feedthrough wall mount. EH16MTS Additional features include an EM16 feedthrough wall mount and sun shroud. EH16-2 Additional features include a heater/blower and 24 VAC camera power; 10 W enclosure power consumption*. EH16-2MT Additional features include a heater/blower, 24 VAC camera power, and an EM16 feedthrough wall mount; 10 W
EH16-2MTS Additional features include a heater/blower, 24 VAC camera power, an EM16 feedthrough wall mount, and an SS16
EH16-3 Additional features include a heater/blower and 24 VAC camera power (includes a 4-inch wire tie); 10 W enclosure
EH16-3MT Additional features include a heater/blower, 24 VAC camera power, and an EM16 feedthrough wall mount (includes a
EH16-3MTS Additional features include a heater/blower, 24 VAC camera power, an EM16 feedthrough wall mount (includes a
EH16-2P Additional features include a heater/blower and 802.3af-compatible PoE camera power; 10 W enclosure power
EH16-2PMT Additional features include a heater/blower, 802.3af-compatible PoE camera power, and an EM16 feedthrough wall
EH16-2PMTS Additional features include a heater/blower, 802.3af-compatible PoE camera power, an EM16 feedthrough wall
EH16-8P Additional features include PoE IEEE802.3at input to provide heater/blower power and 802.3af-compatible camera
EH16-8PMT Additional features include PoE IEEE802.3at input to provide heater/blower power and 802.3af-compatible camera
EH16-8PMTS Additional features include PoE IEEE802.3at input to provide heater/blower power and 802.3af-compatible camera
Table A. Indoor/Outdoor Enclosure Models
enclosure power consumption*.
sun shroud; 10 W enclosure power consumption*.
power consumption*; 25 W maximum power consumption capacity.
4-inch wire tie); 10 W enclosure power consumption*; 25 W maximum power consumption capacity.
4-inch wire tie), and an SS16 sun shroud; 10 W enclosure power consumption*; 25 W maximum power consumption capacity.
consumption*; 25 W maximum power consumption capacity.
mount; 10 W enclosure power consumption*; 25 W maximum power consumption capacity.
mount, and an SS16 sun shroud; 10 W enclosure power consumption*; 25 W maximum power consumption capacity.
power; 10 W enclosure power consumption*; 25 W maximum power consumption capacity.
power, and an EM16 feedthrough wall mount; 10 W enclosure power consumption*; 25 W maximum power consumption capacity.
power, an EM16 feedthrough wall mount, and an SS16 sun shroud; 10 W enclosure power consumption*; 25 W maximum power consumption capacity.
*Enclosure power consumption does not include camera wattage.
4 C3489M-B (3/14)

PACKAGE CONTENTS

Qty Description
1 EH16 Series enclosure 1 Installation manual 1 Screw, 1/4-20 x 3/8-inch, Phillips 1 Washer, 1/4-inch split lock 2 Screws, M6 x 1.0 P x 12 mm, T30 Torx head 1 Gland and nut, PG9 cable 1 Gland and nut, PG11 cable 1 Wire tie, 4-inch (EH16-3 model only) 1 Cat5 PoE cable with RJ-45 connector 1 RJ-45 connector for data or data/PoE connections (EH16-2P and EH16-8P models only) 1 EM16 mount (optional) 1 SS16 sun shroud (optional)

USER-SUPPLIED TOOLS

A T30 Torx driver and a Phillips screwdriver are required for installation but are not included. A flat-head screwdriver might also be needed for all models except the EH16 and EH16MT. A Phillips screwdriver, flat-head screwdriver, or 1/4-inch nut driver is needed for the EH16-3 only. The T30 Torx driver is needed to secure the enclosure to all mounts. It is also needed to open and close the enclosure and to secure the pan/tilt (swivel head) on the EM16 mount.
C3489M-B (3/14) 5
Loading...
+ 11 hidden pages