Pelco EH1000 User Manual

C401M-C (12/99) EH1000 Ceiling Enclosure
®
3500 Pelco Way, Clovis, CA 93612-5699 USA
In North America & Canada: Tel (800) 289-9100 FAX (800) 289-9150
International Customers: Tel +1 (559) 292-1981 FAX +1 (559) 348-1120
www.pelco.com
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclo­sure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
This symbol indicates that danger­ous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and main­tenance instructions in the litera­ture accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
DESCRIPTION
The EH1000 low-profile ceiling enclosure for 2/3-inch format cameras is designed to be mounted in fixed or dropped ceilings. The upper section mounted above the ceiling is constructed of alu­minum to meet most fire code requirements for installation in open plenum ceilings.
NOTE:
The camera mounting bracket is reversible, to accom­modate various camera and lens combinations.
The EH1000 is engineered for ease of installation and service. The lower section is hinged to provide convenient access for adjusting camera and lens. The upper section has generous interior dimensions which allow additional camera angle adjustments to be made.
The EH1000 is equipped with a tamper-resistant lock for security protection. Cable entry is through conduit knockouts.
INSTALLATION
To mount the EH1000 directly into a fixed or dropped ceiling, perform the following steps:
1. Determine the location and direction of the enclosure to be mounted. Ideally, the enclo­sure cutout should be parallel and adjacent, or perpendicular, to any ceiling structure. Avoid cutting into any ceiling structural members.
2. Open the cover of the enclosure to expose the mounting holes in the flange.
3. Remove any appropriate knockouts.
4. Insert the enclosure into the opening and secure with the appropriate fasteners.
5. Mount the camera and lens onto the adjustable mounting bracket. Adjust the position of the camera and lens to clear the enclosure cover when closed. Tighten the mounting bracket fasteners.
6. Route the appropriate cables into the enclosure. Make all necessary electrical connec­tions.
7. Close and lock the cover.
NOTE:
The instructions pro­vided are for installation in a 2' x 2' ceiling tile. If mounting in a 2' x 4' ceiling tile, you will need to cut the ceiling tile in half and install an additional “T” rail for support.
Installation Using E1003 Mounting Plate
To install the EH1000 Ceiling Enclosure in dropped or false ceilings utilizing the E1003 Mount­ing Plate, perform the following steps. Refer to Figure 1.
The E1003 is supplied as follows:
Quantity Description
1 Plate, square 1 Plate, round 8 Spacers 8 Screws, 10-32 x 1-inch
1. Place the E1003 (square and round plates, items 1 and 2) on a flat surface with the painted surface up.
2. Open the lid of the enclosure (EH1000) and insert the enclosure into the rectangular opening.
3. Position the spacers (item 3) provided between the mounting flange of the enclosure and the round plate of the E1003, aligning them with the eight mounting holes.
4. Secure the enclosure to the E1003 with the screws (item 4) provided, making sure the screws pass through the spacers. Tighten the hardware.
5. Mount the enclosure into the 2 ft x 2 ft opening in the ceiling.
6. Refer to steps 3, 5, 6, and 7 in the previous section for final installation instructions.
CARE AND MAINTENANCE
Regularly scheduled maintenance will prolong the operational life and appearance of the equipment.
CAUTION:
Do not use water, liquid or spray cleaners of any kind on
inner surface of the enclosure.
1. If dust or other debris accumulates on the inside of the lower enclosure, remove the par­ticles with clean air pressure only. Compressed air cans are available from commercial photographic equipment and supply dealers.
2. Clean the outer surface of the enclosure and the inner surface of the viewing window with a non-abrasive cleaning cloth and anti-static cleaner that is safe for use on acrylic plastic. Do not use kerosene or similar substances that can scratch the surface.
SPECIFICATIONS
MECHANICAL
Camera Mounting: Adjustable bracket; supports a 10-pound (4.5 kg) maximum load Max.
Camera/Lens Size: Accepts camera/lens combinations up to 4.5" H x 15.0" L x 6.5" W
(11.43 x 38.10 x 16.51 cm)
Ceiling Mounting: Upper section flange-mounted to fixed ceiling or E1003 rotating mounting
plate for false ceilings Viewing Window: Lucite® SAR (Super Abrasion Resistant Acrylic) Cable Entry: Conduit knockouts Lock: Key lock
GENERAL
Certification: UL listed, NEMA Type 1 enclosure suitable for plenum use Construction: Upper section, 5052-H32 aluminum
Lower section, vacuum-formed ABS plastic Color: Upper section, alodine
Dimensions: See Figure 2 Weight: 5 lb (2.268 kg)
(Design and product specifications subject to change without notice.)
Lower section, white textured
Loading...