IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform
to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain
and moisture.
3. Only use replacement parts recommended by Pelco.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of
electric shock is present within
this unit.
This symbol indicates that there
are important operating and maintenance instructions in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
DESCRIPTION
The EH1000 low-profile ceiling enclosure for 2/3-inch format cameras is designed to be mounted
in fixed or dropped ceilings. The upper section mounted above the ceiling is constructed of aluminum to meet most fire code requirements for installation in open plenum ceilings.
NOTE:
The camera mounting
bracket is reversible, to accommodate various camera and lens
combinations.
The EH1000 is engineered for ease of installation and service. The lower section is hinged to
provide convenient access for adjusting camera and lens. The upper section has generous
interior dimensions which allow additional camera angle adjustments to be made.
The EH1000 is equipped with a tamper-resistant lock for security protection. Cable entry is
through conduit knockouts.
INSTALLATION
To mount the EH1000 directly into a fixed or dropped ceiling, perform the following steps:
1. Determine the location and direction of the enclosure to be mounted. Ideally, the enclosure cutout should be parallel and adjacent, or perpendicular, to any ceiling structure.
Avoid cutting into any ceiling structural members.
2. Open the cover of the enclosure to expose the mounting holes in the flange.
3. Remove any appropriate knockouts.
4. Insert the enclosure into the opening and secure with the appropriate fasteners.
5. Mount the camera and lens onto the adjustable mounting bracket. Adjust the position of
the camera and lens to clear the enclosure cover when closed. Tighten the mounting
bracket fasteners.
6. Route the appropriate cables into the enclosure. Make all necessary electrical connections.
7. Close and lock the cover.
NOTE:
The instructions provided are for installation in a
2' x 2' ceiling tile. If mounting in
a 2' x 4' ceiling tile, you will need
to cut the ceiling tile in half and
install an additional “T” rail for
support.
Installation Using E1003 Mounting Plate
To install the EH1000 Ceiling Enclosure in dropped or false ceilings utilizing the E1003 Mounting Plate, perform the following steps. Refer to Figure 1.
The E1003 is supplied as follows:
Quantity Description
1 Plate, square
1 Plate, round
8 Spacers
8 Screws, 10-32 x 1-inch
1. Place the E1003 (square and round plates, items 1 and 2) on a flat surface with the
painted surface up.
2. Open the lid of the enclosure (EH1000) and insert the enclosure into the rectangular opening.
3. Position the spacers (item 3) provided between the mounting flange of the enclosure and
the round plate of the E1003, aligning them with the eight mounting holes.
4. Secure the enclosure to the E1003 with the screws (item 4) provided, making sure the
screws pass through the spacers. Tighten the hardware.
5. Mount the enclosure into the 2 ft x 2 ft opening in the ceiling.
6. Refer to steps 3, 5, 6, and 7 in the previous section for final installation instructions.
CARE AND MAINTENANCE
Regularly scheduled maintenance will prolong the operational life and appearance of the equipment.
CAUTION:
Do not
use water, liquid or spray
cleaners of any kind on
inner surface of the enclosure.
1. If dust or other debris accumulates on the inside of the lower enclosure, remove the particles with clean air pressure only. Compressed air cans are available from commercial
photographic equipment and supply dealers.
2. Clean the outer surface of the enclosure and the inner surface of the viewing window with
a non-abrasive cleaning cloth and anti-static cleaner that is safe for use on acrylic plastic.
Do not use kerosene or similar substances that can scratch the surface.
SPECIFICATIONS
MECHANICAL
Camera Mounting: Adjustable bracket; supports a 10-pound (4.5 kg) maximum load
Max.
Camera/Lens Size: Accepts camera/lens combinations up to 4.5" H x 15.0" L x 6.5" W
(11.43 x 38.10 x 16.51 cm)
Ceiling Mounting: Upper section flange-mounted to fixed ceiling or E1003 rotating mounting
plate for false ceilings
Viewing Window: Lucite® SAR (Super Abrasion Resistant Acrylic)
Cable Entry: Conduit knockouts
Lock: Key lock
GENERAL
Certification: UL listed, NEMA Type 1 enclosure suitable for plenum use
Construction: Upper section, 5052-H32 aluminum
Lower section, vacuum-formed ABS plastic
Color: Upper section, alodine
Dimensions: See Figure 2
Weight: 5 lb (2.268 kg)
(Design and product specifications subject to change without notice.)