Pelco C653M-D User Manual

MCS Series
Master Power Supply
Installation/
Operation Manual
C653M-D (9/03)
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel +1 (559) 292-1981 or FAX +1 (559) 348-1120
IMPORTANT SAFEGUARDS AND WARNINGS
Observe the following warnings before installing and using this product.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources, such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Only use attachments/accessories specified by the manufacturer.
10. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer or sold with the apparatus. When a cart is used, use caution when moving the cart/ apparatus combination to avoid injury from tip-over.
11. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, the apparatus does not operate normally, or the apparatus has been dropped.
WARNING:
To reduce the risk of fire or electric
shock, do not expose this apparatus to rain or moisture.
WARNING:
Risk of fire; do not inter­connect outputs.
12. Apparatus shall not be exposed to dripping or splashing, and no objects filled with liquids, such as vases, shall be placed on the apparatus.
13. To reduce the risk of shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
14. An ALL-POLE MAINS SWITCH with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building.
15. The installation method and materials should be capable of supporting four times the weight of the unit.
16. Only use replacement parts Pelco recommends.
17. After replacing/repairing this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and mainte­nance instructions in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
2 Pelco Manual C653M-D (9/03)
DESCRIPTION
The MCS Series consists of multi-output 24 VAC indoor power supplies. These power supplies provide output for 4, 8, or 16 cameras from a single source and come in 2, 5, 10, and 20 amp capacities. To compensate for voltage losses over long wire runs, 28 VAC outputs are also available on most models. The power supplies allow for 120 or 240 VAC line input. Higher capacity models can handle pan and tilt and receiver operation in addition to the camera when they are used with integrated systems such as the Spectra® dome and Esprit
Each output on the MCS “S” and “SB” (switched) Series models features its own LED power indicator and three-position switch (up = 24 VAC, center = off, down = 28 VAC). The switch lets you individually turn each output off or quickly select between 24 and 28 VAC without reconnecting wires.
All MCS Series models are available with either glass fuses or self-resetting circuit breakers (poly switches). The following bullets explain the advantages and disadvantages of each type:
Glass fuses provide more protection than circuit breakers because they act faster and
Circuit breakers reset themselves when the fault is corrected, which eliminates the
Since circuit breaker models do not require fuses and automatically reset themselves after the fault is corrected, the breakers are not accessible.
®
Integrated Positioning System.
are more precise. However, they are designed for one-time use and must be replaced when they blow.
need to replace fuses. However, they react more slowly, are affected by temperature, and are not nearly as accurate—the amount of current required to trip one can vary as much as 100 percent.
MODELS
Model Number
MCS4-2 4 2 1 120/240 24 0.44 X X X X
MCS4-2B 4 2 1 120/240 24 0.44 XXXXX
MCS8-5 8 5 3 120/240 24, 28 1.10/0.57 X X X X
MCS8-5B 8 5 3 120/240 24, 28 1.10/0.57 XXXXX
MCS16-10 16 10 3 120/240 24, 28 2.20/1.15 X X X X
MCS16-10B 16 10 3 120/240 24, 28 2.20/1.15 XXXXX
MCS16-10S 16 10 3 120/240 24, 28 2.20/1.15 X X 16 16
MCS16-10SB 16 10 3 120/240 24, 28 2.20/1.15 X X X 16 16
MCS16-20 16 20 3 120/240 24, 28 4.40/2.30 X X X X
MCS16-20B 16 20 3 120/240 24, 28 4.40/2.30 XXXXX
MCS16-20S 16 20 3 120/240 24, 28 4.40/2.30 X X 16 16
MCS16-20SB 16 20 3 120/240 24, 28 4.40/2.30 X X X 16 16
Outputs
Supply Current
(Amps)
Max Current Per
Channel (Amps)
Input Voltage
(VAC)
Output Voltage
(VAC)
Required Input
Current (Amps)
Fuses
Circuit Breakers
Surge Protection
Class 2 Outputs
On/Off Switch
Power LED
Pelco Manual C653M-D (9/03) 3