Pelco C490M-D User Manual

®
HS1000 High-Security
Camera Enclosure
Installation/Operation Manual
C490M-D (1/96)
PELCO • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com
Pelco Manual C490M-D (1/96) 13
(800) 289-9100 or (1-559) 292-1981 • FAX (800) 289-9150 or (1-559) 292-3827
Section Page
1.0 WARNINGS ....................................................................................................................................... 1
2.0 SCOPE ............................................................................................................................................ 2
3.0 DESCRIPTION .................................................................................................................................. 2
4.0 INSTALLATION ................................................................................................................................. 2
4.1 CEILING MOUNTING (FLUSH)............................................................................................... 3
4.2 MID-WALL MOUNTING ........................................................................................................... 4
4.3 SPEAKER INSTALLATION ...................................................................................................... 4
4.4 OPTIONAL HB6000, HB6000/220, and HB6024 HEATER/BLOWER KITS............................4
4.4.1 Recommended Cable Size .................................................................................................. 4
4.4.2 Heater/Blower Kit Installation ...............................................................................................5
4.4.2.1 Heater Assembly..................................................................................................... 5
4.4.2.2 Blower/PCB Assembly ............................................................................................ 5
4.4.2.2 Heater/Blower Wiring .............................................................................................. 5
4.5 ELECTRICAL CONNECTION ................................................................................................. 6
4.6 TAMPER SWITCH INSTALLATION ......................................................................................... 6
4.6.1 Tamper Switch Wiring .......................................................................................................... 6
5.0 CARE AND MAINTENANCE ............................................................................................................. 6
6.0 MECHANICAL PARTS LIST FOR HS1000 ENCLOSURE................................................................ 8
7.0 EXPLODED ASSEMBLY DIAGRAM ................................................................................................. 9
8.0 SPECIFICATIONS ........................................................................................................................... 10
9.0 MODELS ......................................................................................................................................... 10
9.1 OPTIONS............................................................................................................................... 10
10.0 WARRANTY AND RETURN INFORMATION ................................................................................. 11
ii Pelco Manual C490M-D (1/96)
LIST OF ILLUSTRATIONS
Figure Page
1 HS1000 Dimension Drawing .......................................................................................................... 3
2 HB6000, HB6000/220, and HB6024 Assembly .............................................................................. 5
3 HS1000 Series Tamper Switch Installation .................................................................................... 6
4 HB6000/220 Heater/Blower Kit Wiring Diagram (230 VAC) ........................................................... 7
5 HB6000 Heater/Blower Kit Wiring Diagram (120 VAC) .................................................................. 7
6 HB6024 Heater/Blower Kit Wiring Diagram (24 VAC) .................................................................... 8
7 HS1000 Enclosure Exploded Assembly Diagram .......................................................................... 9
REVISION HISTORY
Manual # Date Comments
C490M 5/90 Original version.
C490M-A 12/94 Revised manual to include new exploded assembly
diagram, updated parts list, and modified wall mounting instructions as per ECO# 93-245.
C490M-B 9/95 Revised to include wiring instructions for tamper switch
and metric equivalents for specifications.
C490M-C 11/95 Revised to include updated tamper switch/bracket part
numbers and exploded view diagram.
C490M-D 1/96 Revised to include tamper switch installation, specifica-
tion description and new part numbers per ECO 95-397.
Pelco, the Pelco Logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. © Copyright 1996, Pelco. All rights reserved. Endura and ExSite are trademarks of Pelco.
Pelco Manual C490M-D (1/96) iii
(This page intentionally left blank.)
iv Pelco Manual C490M-D (1/96)
INSTALLATION/OPERATION HS1000 HIGH-SECURITY CAMERA ENCLOSURE
1.0 WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by
Qualified Service Personnel and conform to all Local codes.
2. Unless the unit is specifically marked as a NEMA
Type 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is designed for Indoor use only and it must not be installed where exposed to rain and moisture.
The product may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present
within this unit.
3. Only use replacement parts recommended by Pelco.
4. The installation method and materials should be
capable of supporting 4 times the weight of the enclosure, camera and lens combination.
5. The camera and lens combination shall not exceed
20 lbs (9.06 kg).
This symbol indicates that there are important operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
RISK OF ELECTRIC SHOCK.
CAUTION:
DO NOT OPEN.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
Pelco Manual C490M-D (1/96) 1
2.0 SCOPE
4.0 INSTALLATION
The information within this manual covers the installa­tion of the HS1000 High Security Camera Enclosure.
Installation should be in accordance with all applicable local and national electric codes, utilizing approved ma­terials only.
3.0 DESCRIPTION
The HS1000 is a large, high-security camera enclosure designed for indoor “corner mount” installation for such applications as parking garages, prisons, detention cells, etc., requiring maximum protection from vandalism.
Constructed of heavy gauge steel, the HS1000 will ac­cept most 2/3-inch format cameras with fixed focal length lenses ranging in size from 4 mm to 75 mm. There is no exposed mounting hardware securing the HS1000 to its mounting surface. Opening the enclo­sure can only be accomplished with a specially designed tool, eliminating the possibility of the enclosure being opened by unauthorized personnel. In addition, a fac­tory-installed tamper switch is mounted on the secured access cover.
Before installing the HS1000 to a wall/ceiling, make certain that the mounting surfaces are able to support the full weight of the enclosure, plus the camera/lens and any other options, (i.e., speakers, infrared illumi­nators, heater/blower kits and/or hoods).
The tilt table and the tilt table mounting bracket may be removed to provide adequate clearance for mount­ing the enclosure.
The front cover and bottom plate can be removed from the mounting frame to simplify installation.
NOTE: The eight (8) to twelve (12) fasteners required to secure the HS1000 to a wall/ceiling (minimum 3/8-inch diameter fasteners recommended) are not supplied.
Designed to fit flush to the ceiling in a corner, an op­tional hood (HS1000H) allows the HS1000 to be mounted lower on the wall and still retain the integ­rity of the enclosure. Provisions are made for mount­ing 4-inch (10.16 cm) speakers on either side of the enclosure. The hinged front is supplied with an im­pact-resistant Lexan window with adequate area for the installation of an infrared illuminator.
2 Pelco Manual C490M-D (1/96)
4.1 CEILING MOUNTING (FLUSH)
To mount the enclosure to a wall/ceiling, perform the following steps:
1. Open the front cover by removing the four (4) 1/4­20 “Tampruf” screws. A special socket is provided (fits 1/4-inch square drive). The cover hinges down.
2. Using the mounting bracket as a template, mark and drill holes in the mounting surfaces.
3. Attach the enclosure with the required fasteners.
4. Route required cables through the back and/or top of the enclosure.
5. Mount the camera/lens to the tilt table.
6. Make all appropriate connections (i.e., camera power, video (coax), lens, speakers, infrared illu­minators, heater/power kits).
7. Position the camera and tighten the 1/4-20 fasten­ers to secure the tilt table in place.
8. Close the cover and check that all components clear. Secure the cover with the four (4) 1/4-20 “Tampruf” screws provided.
Figure 1. HS1000 Dimension Drawing
Pelco Manual C490M-D (1/96) 3
4.2 MID-WALL MOUNTING
To mount the enclosure mid-wall, use the optional hood, HS1000H, and perform the following steps:
1. Follow steps 1-7 in Section 4.1.
2. Attach the hood to the enclosure with the required fasteners provided (minimum 3/8" diameter rec­ommended).
4.4 OPTIONAL HB6000, HB6000/220, AND HB6024 HEATER/BLOWER KITS
The HB6000, HB6000/220, and HB6024 heater/blower kits require 120 VAC, 230 VAC, or 24 VAC respectively. They provide 80 watts of heat which is thermostati­cally controlled to turn on at 40°F (4.44° C) and turn off at 60°F (15.56° C). They also provide internal air circulation which is thermostatically controlled to turn on at 110°F (43.33° C) and off at 80°F (26.67° C).
3. Close the cover and check that all components clear. Secure the cover with the four (4) 1/4-20 “Tampruf” screws provided.
4.3 SPEAKER INSTALLATION
The HS1000 provides two (2) positions for mounting small speakers (3" x 3" bolt pattern) to be provided by the user.
The speaker grills are shipped with a cover plate mounted over each on the inside. This plate must be removed prior to speaker installation.
NOTE: The speakers mount to the front cover of the enclosure. Be sure to leave an adequate loop of cable to allow the cover to be opened.
Recommended Cable Sizes
4.4.1 Recommended Cable Size
CAUTION: When using a single power
source for both the camera and accessories, the camera power consumption must be taken into consideration when determining the wire gauge.
The cable sizes listed in the table below, should be con­sidered as the minimum recommended sizes for use with the combination of blower/heater/camera.
Model Input Voltage Consumption Cable Size Cable Distance
HB6000 120 VAC 90 watts 22 Awg 464.7 ft (141.6 m)
20 Awg 738.9 ft (225.2 m) 18 Awg 1,175.5 ft (358.7 m) 16 Awg 1,865.7 ft (568.7 m)
HB6000/220 230 VAC 90 watts 24 Awg 1,047.4 ft (319.2 m)
22 Awg 1,666.0 ft (507.8 m) 20 Awg 2,649.2 ft (807.5 m) 18 Awg 4,214.6 ft (1,284.6 m) 16 Awg 6,688.8 ft (2,038.7 m)
HB6024 24 VAC 90 watts 20 Awg 31.5 ft (9.6 m)
18 Awg 50.2 ft (15.3 m) 16 Awg 79.6 ft (24.3 m) 14 Awg 127.0 ft (38.7 m)
4 Pelco Manual C490M-D (1/96)
4.4.2 Heater/Blower Kit Installation
4.4.2.2 Blower/PCB Assembly
To install the HB6000/HB6000/220/HB6024, perform the following steps (refer to Figure 2).
4.4.2.1 Heater Assembly
1. Open the cover.
2. The heater bracket is designed to attach to any two (2) adjacent studs used in retaining the window.
3. Remove any two (2) adjacent nuts and washers on both sides of the window.
4. Place the heater brackets on the studs, with the heat­ers angled away from the window, then replace and tighten the hardware.
1. Open the cover.
2. On the HS1000, the blower/PCB bracket is designed to attach to any two (2) adjacent studs used in retain­ing the bottom plate.
3. Remove any two adjacent nuts and washers retain­ing the bottom plate to the mounting frame.
4. Place the blower/PCB bracket over the studs, then replace and tighten the hardware.
4.4.2.3 Heater/Blower Wiring
The blower is factory wired to the PCB assembly. Con­nect the heaters to the PCB assembly as shown in the respective wiring diagrams (Figure 4, Figure 5, or Figure
6). Supply AC line voltage (230 VAC, 120 VAC, or 24
VAC) as shown.
Figure 2. HB6000, HB6000/220, and HB6024 Assembly
Pelco Manual C490M-D (1/96) 5
4.5 ELECTRICAL CONNECTION
4.6.1 Tamper Switch Wiring
After the cable has been routed, all wire connections should be made (i.e., video, lens, camera power, heaters). A 6-position terminal block has been provided to assist in this.
CAUTION: When a single power source is used for both the camera and accessories, the camera power consumption must be taken into consideration when determining the wire gauge. Also, make certain that all electrical connections are done properly and meet electrical codes.
4.6 TAMPER SWITCH INSTALLATION
The HS1000 enclosures come standard from the fac­tory with a tamper switch installed. Should it become necessary to install a replacement switch, refer to Fig­ure 3 for the correct position of the bracket/switch and perform the following steps:
1. Remove the front cover.
2. Install the bracket/switch and secure with lockwashers and nuts.
The tamper switch comes with both a “Normally Open” contact and a “Normally Closed” contact.
For a “Normally Open” circuit, use the “open ” and “com­mon” terminals; for a “Normally Closed” circuit, use the “closed” and “common” terminals.
5.0 CARE AND MAINTENANCE
Maintenance performed at regular intervals will help pro­long the operational life and appearance of the equipment.
Clean the Lexan window with a mild nonabrasive deter­gent in water with a soft cloth regularly to maintain pic­ture clarity. For a heavily soiled window, use vinyl cleaner.
NOTE: Pelco offers a 24-hour, seven-day-a week Technical Assistance Program (TAP) designed to assist any customer with a technical problem involving Pelco equipment whether it’s the weekend or late at night. For technical assistance dial (800) 289-9100 and you will be connected to a Pelco TAP member who is trained to answer your questions.
Pelco also guarantees one-day turnaround on any Pelco equipment sent in for repair. This includes warranty and non-warranty items. Refer to the section on warranty and return information in this manual for the proper proce­dure.
Figure 3. HS1000 SeriesTamper Switch Installation
6 Pelco Manual C490M-D (1/96)
Figure 4. HB6000/220 Heater/Blower Kit Wiring Diagram (230 VAC)
Figure 5. HB6000 Heater/Blower Kit Wiring Diagram (120 VAC)
Pelco Manual C490M-D (1/96) 7
Figure 6. HB6024 Heater/Blower Kit Wiring Diagram (24 VAC)
6.0 MECHANICAL PARTS LIST FOR HS1000 ENCLOSURE (FIGURE 7)
Item No. Qty Description Part Number
11Plate, Cover, Front HS10004013COMP 22Plate, Grill, Block-Off HS80004115COMP 31Window, HS1000, Clear, 12" x 15" x .50" HS100010009 41Switch, Tamper SWI1DM401 51Bracket, Switch, Break-In HS10004313COMP 61Bracket, Mounting HS10004011COMP 71Hood, Mid Wall Mount (optional accessory) HS1000H 81Tilt Table AH80004013COMP
91Bracket, Tilt Table Mount AH80004014COMP 10 1 Plate, Bottom, Corner Mount HS10004005COMP 11 1 Hinge, Cover HS10004008COMP
A111/4-20 Hex, Finished Nut SS ZH1/4-20NUTCH
B13Washer, Split Lock, 1/4-inch SS ZH1/4WSSL
C17Washer, Flat, 3/16-inch SS ZH260X562X65C D6 Nut Lock 1/4-20 Nylon Insert Lock Nut ZH1/420NUTCHN
E6Washer, Fender, 1/4-inch Black Oxide ZH255X1.50X62
F2Bolt, 1/4-20 x 5/8-inch, Hex C/S SS ZH1/420X.625CH
G4 Nut, Hex, 10-32 SS ZH10-32NUTSH H4 Washer, Split Lock, #10 SS ZH10LWSSL
I4Washer, Flat, #10 SS ZH204X436X60C
J4Screw, 1/4-20 x 1/2", Round, Tampruf, #10 SS ZH1/4-20X.50SRT
8 Pelco Manual C490M-D (1/96)
7.0 EXPLODED ASSEMBLY DIAGRAM
Figure 7. HS1000 Enclosure Exploded Assembly Diagram
Pelco Manual C490M-D (1/96) 9
8.0 SPECIFICATIONS
9.0 MODELS
MECHANICAL
Window: 1/2" (12.7 mm) thick impact and
abrasion resistant clear Lexan
Camera Mounting: Adjustable tilt table
Maximum Camera/Lens Size: Accepts camera/lens combinations
(including BNC connector) up to:
12.0" L x 6.0" W x 6.0" H (30.48 cm x 15.24 cm x 15.24 cm)
Enclosure Mounting: Twelve (12) .390" (0.99 cm) diam-
eter holes on protected rear surfaces (top and back)
Security: Tamper-resistant screws
N.O./N.C. switch contact on cover
Tamper Switch: Plunger type door switch with “pull
to cheat” feature. N.O./N.C. contacts clearly marked on body of switch. DM electrical rating: 10A, 125V. Plunger type with .20" (0.51 cm)
The HS1000 high-security corner mount enclosure has been designed for installations such as parking garages, prisons, detention cells and many other areas requiring maximum protection from vandalism. Below is a list of available HS1000 enclosure options.
9.1 OPTIONS
HS1000H Hood for mid-wall mounting of
HS1000 enclosure.
HB6000 120 VAC thermostatically controlled
heater and blower.
Provides 80 watts of heat: activates ON at 40°F (4.44° C); and OFF at 60°F (15.56° C).
Provides internal air circulation: ac­tivates ON at 110°F (43.33° C); and OFF at 80°F (26.67° C).
HB6000/220 Same as HB6000 except operates at
230 VAC.
HB6024 Same as HB6000 except operates at
24 VAC.
ELECTRICAL
Cable Entry: Six-position terminal block. Cable
entry access through back and top
Tamper Switch: 1/4" (.63 cm) quick connect. N.O./
N.C. clearly marked on switch body. 10A, maximum switching current 125V, maximum switching voltage.
GENERAL
Construction: Formed 10 gauge .134" (0.34 cm)
steel
Finish: Poly vinyl powder coat
Dimensions: See Figure 1
Environment: Indoor, 32° to 120° F (0° to 48.89° C)
Unit Weight: 40 lbs 13 oz (18.36 kg)
10 Pelco Manual C490M-D (1/96)
Notes:
Pelco Manual C490M-D (1/96) 11
10.0 WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years on FT/FR8000 Series fiber optic products.
• Three years on Genex
keyboard).
• Three years on Camclosure
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty.
• Two years on standard motorized or fixed focal length lenses.
• Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and
DF5/DF8 Series fixed dome products.
• Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, includ-
ing when used in continuous motion applications.
• Two years on Esprit® and WW5700 Series window wiper (excluding
wiper blades).
• Eighteen months on DX Series digital video recorders, NVR300
Series network video recorders, and Endura network-based video products.
• One year (except video heads) on video cassette recorders (VCRs).
Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in
continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.
®
Series products (multiplexers, server, and
®
and fixed camera models, except the
Series distributed
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following: If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933
If a warranty repair is required, the Dealer must contact Pelco at (800) 289­9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice
number
3. Details of the defect or problem If there is a dispute regarding the
warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned. Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
12 Pelco Manual C490M-D (1/96)
Loading...