Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120 • DataFAX (1-559) 292-0435
CONTENTS
SectionPage
1.0 GENERAL ..................................................................................................5
1.1 IMPORTANT SAFEGUARDS AND WARNINGS ...............................5
A Video Coaxial Cable Requirements .................................................13
B24 VAC W iring Distances ..................................................................13
CSuspended Ceiling Back Box Exploded Assembly Parts List ...........21
DHard Ceiling Back Box Exploded Assembly Parts List......................22
EPendant Back Box Exploded Assembly Part List ..............................23
FBack Plate Exploded Assembly Parts List (Figure 11) ......................25
REVISION HISTORY
Manual #DateComments
C454M—Original version.
C454M-A6/95Revised to incorporate B.O.M. quantity changes as per
6/23/95Addendum. Incorporated new fuse and fuse holder into
2/27/96Addendum. Section 5.0 Mechanical Parts List revised.
C454M-B4/96Rev . B. Added Section 3.4.2.1 and Figure 16 per ECO#
C454M-C1/98Changed manual to new format and manual pagination.
ECO# 94-445. Added 4-position terminal block information
as per ECO# 94-042. Incorporated new “Front” labeling
to B.O.M. as per ECO# 94-192. Updated manual to new
style standards. Added manual revision history .
wiring diagrams and exploded view diagram as per
ECO# 95-063.
96-061. Changed heater specifications.
Reduced number of models. Revised installation
instructions. Updated exploded assembly diagrams and
parts lists.
Pelco Manual C454M-C (1/98)3
(This page intentionally left blank.)
4Pelco Manual C454M-C (1/98)
1.0 GENERAL
1.1 IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be
observed.
1.Installation and servicing should only be done by Qualified Service Personnel
and conform to all Local codes.
2.Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or
6P enclosure, it is designed for indoor use only and it must not be installed
where exposed to rain and moisture.
3.Only use replacement parts recommended by Pelco.
4.After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed
parts have not been connected to line circuitry.
5.The installation method and materials should be capable of supporting four
(4) times the weight of the enclosure, pan/tilt, camera and lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a
risk of electric shock is present within this unit.
This symbol indicates that there are important operating and
maintenance instructions in the literature accompanying this
unit.
CAUTION:
RISK OF
ELECTRIC SHOCK.
DO NOT OPEN.
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER-
SERVICEABLE P ARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
CAUTION:
Please thoroughly familiarize yourself with the information
in this manual prior to installation and operation.
Pelco Manual C454M-C (1/98)5
1.2 UNPACKING INSTRUCTIONS
Unpack and inspect all parts carefully.
Be sure to save the shipping carton and any inserts. They are the safest material in
which to make future shipments.
If an item appears to have been damaged in shipment, replace it properly in its
carton and contact the factory at 1-800-289-9100 or 1-559-292-1981 for a replacement. (International customers fax 1-559-348-1120 for authorization and instructions.)
If an item needs to be returned to the factory for repair, consult the WARRANTY
AND RETURN section of this manual for instructions.
The following items are supplied:
Suspended Ceiling Models
1Back box with face plate, trim ring, and dome
1Parts bag
2Eye bolts with nuts, flat washers and split lock washers
4T-rail clips
1Installation/Operation Manual (C454M-C)
Hard Ceiling Models
1Back box with trim ring and dome
1Installation/Operation Manual (C454M-C)
Pendant Models
1Bezel with dome
1Pendant cap
1Back box
1Back box gasket
1Parts bag with two O-rings (outdoor models only)
1Installation/Operation Manual (C454M-C)
1.3 RECOMMENDED TOOLS
Pelco does not supply basic tools needed for the installation process. The following
tools are recommended:
Medium Phillips screwdriver
Wire cutter
Wire stripper
BNC crimp tool
Coaxial cable stripper
Hammer and punch (suspended ceiling model only)
Large Phillips screwdriver (suspended ceiling model only)
11 mm wrench (suspended ceiling model only)
Drill (hard ceiling models only)
6Pelco Manual C454M-C (1/98)
The BB14 Series of back boxes is part of the IDS14 Intercept® Series of domes.
The IDS14 Series is an integral system that includes a back box (BB14), dome
drive or fixed mount (DD14), and dome receiver/driver (DRD14).
This manual cover the BB14 Series of back boxes. For installation and operation
instructions for the dome drive, refer to manual C458M-B; for the fixed mount, refer
to C291M-B; and for the dome receiver/driver, refer to C466M-E.
2.1 MODELS
Indoor, Suspended-Grid Ceiling
BB14A100Indoor back box for suspended-grid ceiling; smoked dome;
2.0 DESCRIPTION
hard-wire control. (CE)
BB14A101Indoor back box for suspended-grid ceiling; clear dome; hard-
BB14A110Indoor back box for suspended-grid ceiling; smoked dome; 120
BB14A111Indoor back box for suspended-grid ceiling; clear dome; 120
BB14A120Indoor back box for suspended-grid ceiling; smoked dome; 24
BB14A121Indoor back box for suspended-grid ceiling; clear dome; 24
BB14A130Indoor back box for suspended-grid ceiling; smoked dome; 230
BB14A131Indoor back box for suspended-grid ceiling; clear dome; 230
Indoor, Hard Ceiling
BB14C100Indoor back box for hard ceiling; smoked dome; hard-wire
BB14C101Indoor back box for hard ceiling; clear dome; hard-wire control.
BB14C110Indoor back box for hard ceiling; smoked dome; 120 VAC input.
wire control. (CE)
VAC input. (UL)
VAC input. (UL)
VAC input. (CE, UL)
VAC input. (UL)
VAC input. (CE)
VAC input. (CE)
control. (CE, UL)
(CE, UL)
(UL)
BB14C111Indoor back box for hard ceiling; clear dome; 120 VAC input.
(UL)
BB14C120Indoor back box for hard ceiling; smoked dome; 24 VAC input.
BB14C121Indoor back box for hard ceiling; clear dome; 24 VAC input.
BB14C130Indoor back box for hard ceiling; smoked dome; 230 VAC input.
BB14C131Indoor back box for hard ceiling; clear dome; 230 VAC input.
(CE, UL)
(CE, UL)
(CE)
(CE)
Pelco Manual C454M-C (1/98)7
Indoor, Pendant
BB14E100Indoor, black, pendant-mount back box; smoked dome; hard-
BB14E101Indoor, black, pendant-mount back box; clear dome; hard-wire
BB14E110Indoor, black, pendant-mount back box; smoked dome; 120
BB14E111Indoor, black, pendant-mount back box; clear dome; 120 VAC
BB14E120Indoor, black, pendant-mount back box; smoked dome; 24
BB14E121Indoor, black, pendant-mount back box; clear dome; 24 VAC
BB14E130Indoor, black, pendant-mount back box; smoked dome; 230
BB14E131Indoor, black, pendant-mount back box; clear dome; 230 VAC
Outdoor, Pendant
BB14E200Outdoor, gray, pendant-mount back box; smoked dome; hard-
BB14E200-2Outdoor, gray, pendant-mount back box; smoked dome; hard-
wire control. (CE, UL)
control. (CE, UL)
VAC input. (UL)
input. (UL)
VAC input. (CE, UL)
input. (CE, UL)
VAC input. (CE)
input. (CE)
wire control. Includes 120 VAC heater and blower. (CE)
wire control. Includes 24 VAC heater and blower. (CE)
BB14E200-3Outdoor, gray, pendant-mount back box; smoked dome; hard-
BB14E201Outdoor, gray, pendant-mount back box; clear dome; hard-wire
BB14E201-2Outdoor, gray, pendant-mount back box; smoked dome; hard-
BB14E201-3Outdoor, gray, pendant-mount back box; smoked dome; hard-
BB14E210Outdoor, gray, pendant-mount back box; smoked dome; 120
BB14E211Outdoor, gray, pendant-mount back box; clear dome; 120 VAC
BB14E220Outdoor, gray, pendant-mount back box; smoked dome; 24
BB14E221Outdoor, gray, pendant-mount back box; clear dome; 24 VAC
BB14E230Outdoor, gray, pendant-mount back box; smoked dome; 230
BB14E231Outdoor, gray, pendant-mount back box; clear dome; 230 VAC
wire control. Includes 230 VAC heater and blower. (CE)
control. Includes 120 VAC heater and blower. (CE)
wire control. Includes 24 VAC heater and blower. (CE)
wire control. Includes 230 VAC heater and blower. (CE)
VAC input. Includes 120 VAC heater and blower. (UL)
input. Includes 120 VAC heater and blower. (UL)
VAC input. Includes 24 VAC heater and blower. (CE, UL)
input. Includes 24 VAC heater and blower. (CE, UL)
VAC input. Includes 230 VAC heater and blower. (CE)
input. Includes 230 VAC heater and blower. (CE)
8Pelco Manual C454M-C (1/98)
3.1 MOUNTING
3.0 INSTALLATION
NOTE:
If you are going to install a
heater/blower kit, it should be done
before installing the back box. Refer
to Section 3.2.3, HEATER/BLOWER
KIT FIELD INST ALLA TION.
NOTE:
When installing into a 2' x 4'
(.61 m x 1.22 m) ceiling grid, cut the
ceiling tile in half and install an additional “T” rail for support.
The Intercept® Series of domes provide back box configurations for several applications and environments (refer to Figures 12 and 13).
Installation instructions for the applications listed below will appear in the following
order:
1.Suspended ceiling mounting
2.Hard ceiling mounting
3.Pendant mounting
3.1.1 Suspended Ceiling Mounting
To mount the back box into a suspended ceiling grid, perform the following steps:
1.Determine the location for mounting the back box and remove the appropriate
ceiling tile.
2.Angle the back box through the grid opening and set the box into the grid.
3.From an opening in a grid adjacent to the back box apply the four (4) clips
supplied to the “T” bar to secure the back box to the grid (refer to Figure 1).
4.If additional support is required (such as anchoring with a chain or steel cable
to a support beam above the dome enclosure), install one or both of the 1/4-20
eye bolts and washers that are supplied in the parts bag:
a.Remove one or two of the 1/4-20 screws in the top of the back box.
Figure 1. “T -Bar” Clip Installation
b.Screw a nut about a half inch onto an eyebolt.
c.Slide a split lock washer and flat washer onto the eyebolt.
d.Screw the eyebolt into the back box and lock the eyebolt into place by
tightening the nut with an 11 mm wrench.
e.Repeat steps b-d if you are going to install the second eyebolt.
f .Use a chain or cable to fasten the eyebolt(s) to a support structure in the
ceiling.
Proceed to Section 3.2, WIRING INSTRUCTIONS.
Pelco Manual C454M-C (1/98)9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.