This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to
part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However there is no guarantee that the interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve
Radio-TV Interference Problems.” This booklet is available from the U.S. Government Printing Office,
Washington D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment
can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
WARNING: This product is sensitive to Electrostatic Discharge (ESD). To avoid ESD damage to
this product, use ESD safe practices during installation. Before touching, adjusting or handling thi
product, correctly attach an ESD wrist strap to your wrist and appropriately discharge your body
and tools. For more information about ESD control and safe handling practices of electronics,
please refer to ANSI/ESD S20.20-1999 or contact the Electrostatic Discharge Association
(www.esda.org).
The materials used in the manufacture of this document and its components are compliant to the
requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to
comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrica
and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this
equipment.
4C3425M-D (8/08)
Description
The IS90 Series Camclosure® integrated camera system combines a camera and lens package in a small,
discreet dome. The system is easy to install and can be mounted to the surface of a ceiling/wall or
recessed in a ceiling/wall. The unit supports both BNC and unshielded twisted pair (UTP) video wiring.
Before installing your new system, thoroughly familiarize yourself with the information in this manual.
MODELS
Indoor dome, surface/flush mount, smoked and clear bubble, white finish
Camera TypeLens/IrisNTSCPAL
Color, Wide Dynamic
Range, Day/Night
Color, High
Resolution, Day/
Night
Color, Wide Dynamic
Range
Color, High
Resolution
3-9.5 mm, Day/Night
Varifocal, Auto Iris
9-22 mm, Day/Night Varifocal,
Auto Iris
3-9.5 mm, Day/Night
Varifocal, Auto Iris
9-22 mm, Day/Night Varifocal,
Auto Iris
3-9.5 mm, Varifocal, Auto IrisIS90-CWV9
9-22 mm, Varifocal, Auto IrisIS90-CWV22
3-9.5 mm, Varifocal, Auto Iris
1Assembled IS90 Series Camclosure integrated camera system (back box,
smoked bubble, and camera module)
1Clear bubble with liner
1Adapter plate
28-32 x 1.00-inch Phillips pan head screws
28-32 x 0.75-inch Phillips pan head self-tapping screws
28-32 x 2.50-inch Phillips pan head self-tapping screws
210-32 x 1.50-inch Phillips pan head self-tapping screws
Turn the bubble counterclockwise and lift (refer to Figure2). Place the bubble on a nonabrasive surface.
If the liner is already installed, remove it before installing the unit. To remove the liner, gently lift it from
the unit. Place the liner to the side; it will be reinstalled later with the bubble (refer to Install Liner and Bubble on page 27).
Figure 2. Removing the Bubble
8C3425M-D (8/08)
Installation
You can install the IS90 Series Camclosure integrated camera system into any of the following:
•Mount to the surface of a ceiling/wall (refer to Surface Installation: Ceiling/Wall on page9).
•Install in a suspended ceiling (refer to In-Ceiling Installation: Suspended Ceiling on page 11).
•Install in a fixed ceiling/wall (refer to In-Ceiling Installation: Fixed Ceiling/Wall on page 13).
•Mount to the surface of a 4S standard electrical box (refer to Surface Installation: 4S Standard Electrical Box on page 14).
•Install in a 4S deep electrical box (refer to In-Ceiling Installation: 4S Deep Electrical Box on page 15).
Select the best method for your installation.
UNSHIELDED TWISTED PAIR (UTP) VIDEO
The IS90 Series offers support for unshielded twisted pair (UTP). The UTP video output signal is 1 Vp-p
differential into a 100-ohm load. At a minimum, UTP requires Cat5, 100-ohm twisted pair cable.
SURFACE INSTALLATION: CEILING/WALL
1. Using the template that is supplied, mark the holes on the ceiling/wall for mounting the camera
system and for installing the wiring. Drill the holes. Refer to Figure 3 or Figure 4.
2. Pull video and power wires through the ceiling/wall.
3. Connect the video cable/wires:
•BNC: Connect the BNC connector from the unit to a mating BNC connector.
•UTP: Blue wire = Video +
4. Connect the power wires.
VoltageRed WireBlack Wire
12 VDC+Ground
24 VAC~~
Gray wire = Video -
AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one
side of the transformer to the red wire on all units; connect the other side of the transformer to the
black wire on all units.
NOTE: Failure to connect all AC powered units the same way will cause the cameras to be out of
phase with each other and may produce a vertical roll when switching between cameras.
5. For a non-concrete ceiling/wall, use 6-32 toggle bolts to attach the surface mount ring and back box
to the mounting surface (refer to Figure 3). For a concrete ceiling/wall, use 8-32 mounting hardware
(refer to Figure 4). Mounting hardware is not supplied.
C3425M-D (8/08)9
WALL OR
CEILING
BACK BOX
AND SURFACE
MOUNT RING
Figure 3. Ceiling/Wall Installation
CONCRETE WALL
OR CEILING
6-32 TOGGLE BOLTS
(NOT SUPPLIED)
8-32
MOUNTING
HARDWARE
(NOT SUPPLIED)
BACK BOX
AND SURFACE
MOUNT RING
Figure 4. Concrete Ceiling/Wall Installation
10C3425M-D (8/08)
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.