INSTALLATION
SWM Series Spectra Compact Wall Mount
C293M-B (1/09)
®

Important Safety Instructions

1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Installation shall be done in accordance with all local and national electrical and mechanical codes utilizing only approved materials.
3. Use only installation methods and materials capable of supporting four times the maximum specified load.
4. Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.

Description

The SWM Series Spectra® compact wall mount provides indoor and outdoor wall mounting for Spectra and DF5 Series pendant domes. The mount features cable feedthrough that conceals the electrical wiring to the dome back box. A 1.5-inch NPT pipe thread is provided in the mount to attach the pendant dome. Anti-seize compound is supplied to be applied to the pipe thread. The sun shield used for the outdoor versions of the pendant dome back boxes is readily accepted by the mount.
The mount can be attached to any vertical load-bearing surface or to an SWM-PA Series pole adapter by means of a mounting cleat. A gasket is affixed to the base to protect the interior from moisture.
The mount is constructed of aluminum and has either a light gray or black polyester powder coat finish.

MODELS

SWM-GY Compact wall mount with cable feedthrough for use with Spectra or DF5 Series pendant
SWM-BK Same as SWM-GY, except black finish.
domes. Gray finish.

PARTS LIST

Qty Description
1 Wall mount, gray or black 1 Mounting cleat 1 Adjustment plate 1 10-24 set screw 1 Anti-seize lubricant
2 C293M-B (1/09)

Installation

The SWM can be mounted directly onto a wall, onto a single gang electrical box, or onto a pole using an adapter. Refer to the SWM-PA Series pole adapter manual (C294M) for pole mounting installation instructions.

WALL MOUNTING

To install the SWM Series wall mount directly onto a wall (refer to Figure 1 on page 4):
1. Determine the location where the mount is to be installed.
2. Use the adjustment plate as a template to drill holes into the mounting surface. If the adjustment plate is not required for shimming, it can be discarded after the mounting holes are drilled.
3. Pull the electrical cables from the cable hole in the mounting surface through the cable holes in the adjustment plate (if required), and then through the mounting cleat. Position the cleat so the elongated mounting fastener hole is below the cable entry hole and the embossed arrow is pointing up.
4. Fasten the adjustment plate (if used) and mounting cleat securely to the mounting surface with two fasteners of appropriate length and size (not supplied). If necessary, before tightening the two fasteners, insert shims between the adjustment plate and the mounting surface to create a perpendicular surface on which to attach the wall mount. The lower hole in the mounting cleat is elongated, which allows for vertical alignment adjustment.
5. Pull the electrical cables through the mount, hook the mount onto the top of the mounting cleat, and position the mount flush against the mounting surface. If necessary, loosen the set screw to ensure the mount is flush against the mounting surface. Tighten the set screw in the bottom of the mount only until the mount is snug against the surface. Do not overtighten.
C293M-B (1/09) 3