C2931M (7/05)
PMCD750 DLP
™
Display
Removable On-Screen Code Chart
The PMCD750 will flash a sequence of red and amber lights on the screen to indicate current status or if a fault exists. Cut out these cards for convenient
referencing of the on-screen codes.
Condition Priority Each block represents 0.2 seconds
Door open 1 R R R
Power supply fan failed 2 R Amber
DLP fan failed 3 R Amber R
350V failed 4 R R Amber
Optical engine failed 5
lamp is off
Starts with red;
Lamp failed 6
Lamp off (wait, auto off)
Wait (lamp off, cooling) 8
Lamp off (lamp saver)
3
Lamp off (ready to turn on) 10
amber
Lamp striking (starting) 11
Starts with
2
7 R R Amber Amber
9 Amber Amber R
R R Amber R
R R R R
R R R R
Amber Amber
Amber Amber Amber
Lamp on, no alarms 12 Amber on continuously
R = Red To show the code, press
1
With Priority 1-6, to turn lamp on, cycle off, and then on. If Auto Codes in the Miscellaneous menu is checked, events with Priority 1-5 start the
on-screen code automatically.
2
Lamp Saver turned lamp off; lamp is cooling and will turn on at end of cooling period.
3
A Lamp On command from the remote or from RS-232 commands will turn lamp on.
MONITOR button once.
See footnote 1
Condition Priority Each block represents 0.2 seconds
Door open 1 R R R
Power supply fan failed 2 R Amber
DLP fan failed 3 R Amber R
350V failed 4 R R Amber
Optical engine failed 5 R R Amber R
lamp is off
Starts with red;
Lamp failed 6 R R R R
Lamp off (wait, auto off)
2
7 R R Amber Amber
See footnote 1
Wait (lamp off, cooling) 8 R R R R
Lamp off (lamp saver)
Lamp off (ready to turn on) 10
amber
Lamp striking (starting) 11 Amber Amber Amber
Starts with
Lamp on, no alarms 12
R = Red To show the code, press
1
With Priority 1-6, to turn lamp on, cycle off, and then on. If Auto Codes in the Miscellaneous menu is checked, events with Priority 1-5 start the
on-screen code automatically.
2
Lamp Saver turned lamp off; lamp is cooling and will turn on at end of cooling period.
3
A Lamp On command from the remote or from RS-232 commands will turn lamp on.
3
MONITOR button once.
9 Amber Amber R
Amber Amber
Amber on continuously
Worldwide Headquarters • 3500 Pelco Way • Clovis, California 93612 USA • www.pelco.com
USA & Canada • Tel: 800/289-9100 • Fax: 800/289-9150
International • Tel: 1-559/292-1981 • Fax: 1-559/348-1120
Pelco and the Pelco logo are registered trademarks of Pelco. ©Copyright 2005, Pelco. All rights reserved.
DLP is a registered trademark of Texas Instruments, Inc.