Pelco C2907M-D User Manual

INSTALLATION/OPERATION
®
PelcoNet
NET350 Multimedia Transmission Via Network
C2907M-D (4/05)

Contents

Important Safeguards and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
What Is the PelcoNet NET350 Transmission System? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Instructions for the Network Administrator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Typical Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Radio and Television Interference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
How Do LANs and WANs Work? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Who Should Install the PelcoNet NET350 Transmission System? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
The Transmitter and Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
The Browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Minimum PC Requirements (As Needed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Software Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Optional Compatible Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Front Panel Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Rear Panel Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Mounting the NET350 to the Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Connecting Video Sources or Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Connecting Data Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Connecting Audio Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Connecting an Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Connecting a Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Connecting to a LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Switching on Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Box-to-box Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Configuration Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Configuration Using a Web Browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Setup Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Configuration Page for General Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Configuration Page for MPEG-4 Video Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Configuration Page for Video Decoder Settings (Receiver Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Configuration Page for Audio Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Configuration Page for Alarm Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Configuration Page for Relay Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Configuration Page for COM 1 Interface Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Configuration Page for COM 2 Interface Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Configuration Page for Local COM Interface – Keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Configuration Page for Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Configuration Pages for Media Recording . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Configuration Using a Terminal Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Typical Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Terminal Program Transmitter Menu Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Terminal Program Receiver Menu Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Command Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Live Video and Server Push Video Pages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Displaying Video On a Web Browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
2 C2907M-D (4/05)
Using the Audio Transmission Feature of a Live Video Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Web Browser Control Pages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Matrix Live Video/Server Push Page Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Genex Live Video/Server Push Page Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Spectra Live Video/Server Push Page Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Esprit Live Video/Server Push Page Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Keyboard Live Video/Server Push Page Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Recording and Viewing the Display on a PC and the NET350 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Choosing Where to Store the File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Recording a Snapshot from Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Viewing a Snapshot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Recording the Video Display onto the PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Recording the Video Display Through Compactflash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Viewing the Video Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Media Playback Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Viewing a File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Backing up a File Onto a Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Recording a Snapshot from a File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Software Upload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Resetting the NET350 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Terminal Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Troubleshooting a TCP/IP Network Using a Ping Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Troubleshooting Connection Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Troubleshooting the Video Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Appendix A — Connecting PelcoNet to Various Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Connecting PelcoNet to Various Components with Assorted Keyboards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Connection Scenario 1 – Using a KBD300A In Direct Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Connection Scenario 2 – Using a KBD4000 for Multiplexer Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Connection Scenario 3 – Using a CM9760-KBD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Connecting a Local Keyboard to a PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Connecting PelcoNet COM 1 RS-232 Port to the Genex Multiplexer COM Out Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Connecting PelcoNet to a CM6700 and KBD200A for Remote ASCII Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Connecting PelcoNet to a CM6700 ASCII Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Connecting PelcoNet to a CM9760-DT for Remote Browser Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Connecting PelcoNet to CM9700 for Remote Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Connecting a PelcoNet Transmitter to the CM6800 ASCII Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Connecting PelcoNet to a CM6800 and KBD200A for Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Appendix B — Frequently Asked Questions (FAQs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
C2907M-D (4/05) 3

List of Illustrations

1 Front Panel Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
2 Rear Panel Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
3 Configuration for Box-To-Box Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4 LAN Box-To-Box Connection (Transmitter, Receiver, Fixed Camera) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
5 LAN Box-To-Box Connection (Transmitter, Receiver, Spectra) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
6 LAN Box-To-Box Connection (Transmitter, Receiver, Spectra, Genex) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7 LAN Browser-To-Box Connection (Transmitter, Browser, Fixed Camera) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
8 LAN Browser-To-Box Connection (Transmitter, Browser, Spectra) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
9 LAN Browser-To-Box Connection (Transmitter, Browser, Spectra, Genex) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
10 WAN Box-To-Box Connection (Transmitter, Receiver, Fixed Camera) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
11 WAN Box-To-Box Connection (Transmitter, Receiver, Spectra) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
12 WAN Box-To-Box Connection (Transmitter, Receiver, Spectra, Genex) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
13 WAN Browser-To-Box Connection (Transmitter, Browser, Fixed Camera) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
14 WAN Browser-To-Box Connection (Transmitter, Browser, Spectra) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
15 WAN Browser-To-Box Connection (Transmitter, Browser, Spectra, Genex) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
16 Connection with Pelco Keyboard Control Through a PC (Example Shown with Spectra and Genex) . . . . . . . . . . . . . . . . . .22
17 Securing NET350 to Wall Mount Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
18 Connecting Audio Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
19 Alarm and Relay Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
20 Connecting to the LAN Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
21 PelcoNet Home Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
22 PelcoNet NET350 Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
23 PelcoNet NET350 Setup Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
24 Configuration Page for General Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
25 Configuration Page for MPEG-4 Video Settings (Only One Example Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
26 Configuration Page for Video Decoder Settings (Receiver Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
27 Configuration Page for Audio Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
28 Configuration Page for Alarm Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
29 Motion Detection Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
30 Motion Detection Grid Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
31 Configuration Page for Relay Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
32 Configuration Page for COM 1 Interface Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
33 Configuration Page for COM 2 Interface Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
34 Configuration Page for Local Com Interface – Keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
35 Configuration Page for Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
36 Partition Settings Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
37 Configuration Page for Time Recording Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
38 Configuration Page for Alarm Recording Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
39 Configuration Page for Properties Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
40 Live Video and Server Push Video Pages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
41 PelcoNet NET350 Home Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
42 Device Controls Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
43 Matrix Control Page (Live Video Page Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
44 Genex Control Page (Live Video Page Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
45 Spectra Control Page (Live Video Page Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
46 Esprit Control Page (Live Video Page Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
47 Keyboard Control Page (Live Video Page Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
48 Viewer Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
49 Media Playback Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
50 DB9 Cable Wire Splicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
51 KBD300A (Direct Mode) Connected to a Receiver or Spectra Dome System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
52 KBD4000 Connected to a Multiplexer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
53 CM9760-KBD Connected to a CM9700-CC1 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
54 Connecting a Local Keyboard to a PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
55 Connecting PelcoNet to Genex Using the COM 1 RS-232 Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
56 Using PelcoNet with CM6700 and KBD200A to Provide Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
57 Using PelcoNet with CM6700 to Provide Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
58 Using PelcoNet with CM9760-DT to Provide Remote Control of a 9760 Monitor Output . . . . . . . . . . . . . . . . . . . . . . . . . . .81
59 Using PelcoNet to Transmit Data and Video Between 9700 Nodes (9760 Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
4 C2907M-D (4/05)
60 Using PelcoNet to Receive Data and Video Between 9700 Nodes (9760 Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
61 Manager Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
62 Menu Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
63 Using PelcoNet with CM6800 and KBD200A to Provide Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
C2907M-D (4/05) 5

List of Tables

A Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
B Terminal Command Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
C Live Video Page Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
D LED Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
6 C2907M-D (4/05)

Important Safeguards and Warnings

Observe the following warnings before installing and using this product.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Only use attachments/accessories specified by the manufacturer.
10. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as when the power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, the apparatus does not operate normally, or the apparatus has been dropped.
11. Apparatus shall not be exposed to dripping or splashing, and no objects filled with liquids, such as vases, shall be placed on the apparatus.
12. Warning: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
13. To reduce the risk of shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
14. Unless the unit meets NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P standards, it is designed for indoor use only and must not be installed where exposed to rain and moisture.
15. Only use parts recommended by Pelco.
16. Use only installation methods and materials capable of supporting four times the maximum specified load.

REGULATORY NOTICES

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve Radio-TV
Interference Problems.” This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402.
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.
C2907M-D (4/05) 7

What Is the PelcoNet NET350 Transmission System?

The PelcoNet WANs (wide area networks). This technology is based on the TCP/IP protocol suite and Ethernet technology, providing compatibility with today’s networking standards.
The following devices can be controlled from your computer through Internet Explorer with the PelcoNet NET350 transmission system: Spectra Esprit and the CM6800 matrix.
(Refer to Glossary section for definitions of terms used in this manual.)
NET350 transmission system is technology that lets you view video in real time across a LAN (local area network) and even
®
®
, Genex
multiplexer, CM9700 systems (older CM9760s require CM9760 data translator), CM6700 (through integrated ASCII port, COM 2),

HOW DO LANS AND WANS WORK?

•A LAN consists of multiple computers connected together, sharing information. This information could be files, e-mail, printers, orwith the PelcoNet NET350 transmission systemeven live video and audio.
•A WAN consists of multiple LANs connected through routers and gateways (for example, the Internet).
In any network environment, each device needs a unique address so other computers on the network know how to reach it.
It is similar to a city with street addresses. For the post office to deliver mail to your house, you need a unique street address for the mail carrier to find you. A network is like a city. Like a street address, the IP address on your computer is your address on the network. The IP address is how other computers can find you on the network.
Remember that the IP address must be unique on the network.
When there are multiple networks and you are using the TCP/IP protocol, there must be a way to communicate between the two networks. A physical device called a router is required. The router’s IP address is referred to as the default gateway IP address.
•A cable that connects one computer to another is like a city street you can use to get from one house to another. The cable lets you communicate with each other on the network. This cable is Category 5 cable with RJ-45 connectors at each end. (It looks like a phone cord, only slightly larger.)
®
,

WHO SHOULD INSTALL THE PELCONET NET350 TRANSMISSION SYSTEM?

NOTE: Unless you are very familiar with how computers work, consult your network administrator for help.
Installation is a matter of configuring an IP address using a standard terminal program or Internet Explorer and connecting the PelcoNet NET350 transmission system to the Ethernet network. You should have the following background and experience to configure and install these units:
•Working knowledge of basic network management concepts and terminology
•Working knowledge of tools and procedures for installing and operating sensitive electronic equipment
8 C2907M-D (4/05)

Instructions for the Network Administrator

The PelcoNet NET350 transmission system allows live video transmission to be viewed over TCP/IP-based networks. This section is intended to help the network administrator know what is involved with installing this product and how it will affect the network. The person installing the product will need the following information about the network to make the network function properly.

THE TRANSMITTER AND RECEIVER

•A valid IP address* for each PelcoNet NET350 transmission system unit
Subnet mask*
Default gateway (if applicable)
E-mail server’s IP address (if applicable)
Dedicated maximum allowable amount of bandwidth for live video**
* = Required for the PelcoNet NET350 transmission system to function properly
** = The PelcoNet NET350 transmission system requires a continuous amount of bandwidth to display true live video. Pelco recommends
using switching hubs with the product so the amount of bandwidth available to each unit is constant and reliable.

THE BROWSER

If you plan to use a browser to view live video across the network, there are procedures to complete before you can use the browser, such as installing the ActiveX
®
platform. If you installed Internet Explorer 6.0 from the CD that came with the PelcoNet NET350 transmission system, you
can skip step 1 below. Otherwise, perform the following before trying to use the browser.
1. Internet Explorer 6.0 or higher must be installed before continuing.
2. Set the computer’s display settings to use 16- or 32-bit color.
3. Insert the supplied resource CD. It will open automatically. If it fails to open automatically, perform steps a through d below.
®
a. Click the Start menu in the Windows
operating system.
b. Click Run.
c. In the Open box, type D:\START.EXE (where D:\ = your CD ROM drive letter).
d. Click OK.
4. Click Software and then click Install PelcoNet ActiveX.
5. Follow the on-screen setup instructions to finish installing the plug-in.

MINIMUM PC REQUIREMENTS (AS NEEDED)

PC (Pentium
Network card
Microsoft
Free serial interface and terminal program
Screen resolution of 1024 x 768 or higher, 16- or 32-bit pixel color resolution
RAM of 256 MB
Graphic card (ATI RADEON 7500 or 8500, Matrox G 550 or Parhelia playback capability)
Ethernet card (100 Mbit recommended)
Sound card (required for audio application)
DirectX
®
4 microprocessor, 1.6 GHz) with Windows 98/2000/XP operating system
®
Internet Explorer 6.0 (or higher) or PelcoNet NET350R (receiver) and video monitor
®
8.1 or 9.0 application programming interface software
, or NVIDIA
®
GeForce 3 or 4 with direct show-compatible MPEG-4
C2907M-D (4/05) 9

Overview

NOTE: This manual refers to the PelcoNet NET350 transmission system unit when discussing features, functions, or specifications that apply to
both transmitter and receiver models. “Receiver,” as used in this manual, refers to a PelcoNet NET350 transmission system receiver unless otherwise noted.

DESCRIPTION

The PelcoNet NET350 transmission system is a network video server that encodes and decodes live video, audio, and control data transmitted and received over Ethernet computer networks (either intranet or Internet) using the TCP/IP protocol.
The transmission system consists of two units: a transmitter (NET350T) and a receiver (NET350R)however, only the transmitter is required to use the system. If a receiver is used, video can be displayed on an NTSC or PAL monitor connected to the receiver. If a receiver is not used, video can be displayed on a PC connected to the network through a web browser.
The NET350T includes a CompactFlash
Dual MPEG-4 video streams, each of which can be set up differently, is a special feature of the NET350. For example, one video stream might be set to record at high resolution while the second might have monitoring at a lower resolution.
Transmitters and receivers are identified by IP addresses, just like any other equipment connected to a computer network.
There is a bidirectional serial interface for remote control of peripherals, such as PTZ cameras. The NET350T can transmit and receive audio and the NET350R can receive audio.
®
interface for video storage.
In appropriately configured networks, the multicast function permits simultaneous video transmission in real time to several receivers. For this to work, the UDP and IGMP multicasting protocols must be implemented in the network.

SOFTWARE VERSION

This manual documents PelcoNet NET350 software version 3.0.

PACKAGE CONTENTS

The following are supplied:
•Transmitter (NET350T) or receiver (NET350R)
Universal plug-in power pack with adapters for EU, UK, US, and AU
DB9 cable with pigtail
•Wall mount bracket
Quick installation guide
Software resource CD
OPTIONAL COMPATIBLE PRODUCTS
NET350RK The NET350RK rack mount kit provides rack mounting for the PelcoNet NET350. This kit supports the mounting of one, two, or
three units per rack. Units can be mounted with either front or real panel forward.
10 C2907M-D (4/05)

FRONT PANEL COMPONENTS

The PelcoNet NET350 transmission system uses a compact design. For that reason connectors are placed on both the front and rear panels.
CompactFlash
Key:
1= CompactFlash interface (transmitter only) is a slot for CompactFlash cards and miniature disk drives 2= Alarm I/O terminals for alarm input and relay output (refer to Figure 19) 3=RJ-45 Ethernet connector for connecting to the network (10/100) 4= Power socket 5=LED I lights red with an active alarm 6=LED O lights green when the relay is switched 7=LED L lights green when the unit is connected to the network 8=LED T flashes yellow when data is transmitted 9= Hard reset button

Ethernet Power
Alarm I/O
OI

(Refer to the LEDs section for more information on the LEDs.)

REAR PANEL COMPONENTS

Video In
Key:
1= Video In BNC socket (transmitter) or Video Out BNC socket (receiver) for video source or for an analog video monitor 2= 75 3= Audio I/O bidirectional audio interface; 3.5 mm stereo jack for connecting a loudspeaker or an audio source (monaural line), line level 4= COM2: RS232 serial interface port; 9-pin male sub-D socket for configuration using terminal software 5= COM1: RS232/422/485 serial interface port; 9-pin male sub-D socket for controlling data transmissions (RS-232, RS-422, and RS-485
6 = Power LED for device status and software upload failure (refer to the LEDs section)
Ω slide switch (transmitter) for terminating the video input
protocols) and for configuration using terminal software
Figure 1. Front Panel Components
75
Audio I/O
COM2: RS232
COM1:
RS232/422/485
Power
Figure 2. Rear Panel Components
Refer to the LEDs section for more information on the LEDs and to the Hardware Installation section for information on interfacing peripherals to the unit.
C2907M-D (4/05) 11

Typical Applications

There are two ways to make a high performance multimedia transmission system for computer networks:
One way is to use just the transmitter and connect it through the computer network to a PC with a web browser at the receiving end.
Another way is to connect the transmitter through the computer network to a receiver. This is often called a box-to-box connection because it uses two PelcoNet NET350 transmission system units.
In either case, routing dedicated cables from a camera to a monitor is not required because you can use the existing computer network for that purpose.
Refer to figures 3 through 16 for examples of these configurations. Refer to Appendix A for detailed connection illustrations.
-
TRANSMITTER
LAN/WAN
TCP/IP
INTRANET/INTERNET
75
Video In
75
Video Out
Audio I/O
Audio I/O
COM2: RS232
COM2: RS232
RS232/422/485
RS232/422/485
Figure 3. Configuration for Box-To-Box Connections
COM1:
COM1:
Power
RECEIVER
Power
12 C2907M-D (4/05)
HUB
TRANSMITTER
75
Video In
CAMERA
Audio I/O
AUDIO
(PREAMP)
LINE LEVEL
COM2: RS232
COM1:
RS232/422/485
DATA
Power
RECEIVER
75
Video Out
MONITOR
Audio I/O
AUDIO
COM2: RS232
COM1:
RS232/422/485
DATA
Power
Figure 4. LAN Box-To-Box Connection (Transmitter, Receiver, Fixed Camera)
C2907M-D (4/05) 13
HUB
TRANSMITTER
75
Video In
Audio I/O
COM2: RS232
COM1:
RS232/422/485
Power
VIDEO
DATA
AUDIO
(PREAMP)
SPECTRA
75
Video Out
LINE LEVEL
Audio I/O
COM2: RS232
COM1:
RS232/422/485
RECEIVER
Power
DATA
MONITOR
AUDIO
KEYBOARD
Figure 5. LAN Box-To-Box Connection (Transmitter, Receiver, Spectra)
14 C2907M-D (4/05)
HUB
TRANSMITTER
75
Video In
Audio I/O
COM2: RS232
COM1:
RS232/422/485
Power
VIDEO
GENEX
DATA
SPECTRA
RECEIVER
75
Video Out
Audio I/O
COM2: RS232
COM1:
RS232/422/485
Power
VIDEO
DATA
MONITOR
KEYBOARD
Figure 6. LAN Box-To-Box Connection (Transmitter, Receiver, Spectra, Genex)
C2907M-D (4/05) 15
HUB
TRANSMITTER
75
Video In
Audio I/O
COM2: RS232
COM1:
RS232/422/485
Power
CAMERA
BROWSER
Figure 7. LAN Browser-To-Box Connection (Transmitter, Browser, Fixed Camera)
HUB
TRANSMITTER
75
Video In
Audio I/O
COM2: RS232
COM1:
RS232/422/485
Power
VIDEO
DATA
SPECTRA
BROWSER
Figure 8. LAN Browser-To-Box Connection (Transmitter, Browser, Spectra)
16 C2907M-D (4/05)
HUB
TRANSMITTER
75
Video In
Audio I/O
COM2: RS232
COM1:
RS232/422/485
Power
VIDEO
GENEX
DATA
SPECTRA
RECEIVER
75
Video Out
Audio I/O
COM2: RS232
COM1:
RS232/422/485
Power
VIDEO
DATA
MONITOR
KEYBOARD
Figure 9. LAN Browser-To-Box Connection (Transmitter, Browser, Spectra, Genex)
C2907M-D (4/05) 17
CLOVIS
SERVER
VIDEO
1 OR MORE PCs
ROUTER
HUB
Video In
CAMERA
Video Out
•••••••••••
75
75
Audio I/O
AUDIO
(PREAMP)
LINE LEVEL
Audio I/O
COM2: RS232
COM2: RS232
1 OR MORE PCs
ROUTER
HUB
NEW YORK
SERVER
COM1:
RS232/422/485
COM1:
RS232/422/485
TRANSMITTER
Power
RECEIVER
Power
VIDEO
MONITOR
AUDIO
Figure 10. WAN Box-To-Box Connection (Transmitter, Receiver, Fixed Camera)
18 C2907M-D (4/05)
CLOVIS
SERVER
1 OR MORE PCs
ROUTER
VIDEO
•••••••••••
HUB
75
Video In
SPECTRA
75
Video Out
Audio I/O
DATA
Audio I/O
AUDIO
(PREAMP)
LINE LEVEL
COM2: RS232
COM2: RS232
1 OR MORE PCs
ROUTER
HUB
NEW YORK
SERVER
COM1:
RS232/422/485
COM1:
RS232/422/485
TRANSMITTER
Power
RECEIVER
Power
DATA
MONITOR
AUDIO
KEYBOARD
Figure 11. WAN Box-To-Box Connection (Transmitter, Receiver, Spectra)
C2907M-D (4/05) 19
CLOVIS
SERVER
GENEX
1 OR MORE PCs
ROUTER
Video In
VIDEO
•••••••••••
HUB
75
SPECTRA
Audio I/O
DATA
COM2: RS232
1 OR MORE PCs
ROUTER
HUB
NEW YORK
SERVER
COM1:
RS232/422/485
TRANSMITTER
Power
RECEIVER
75
Video Out
Audio I/O
COM2: RS232
COM1:
RS232/422/485
Power
VIDEO
DATA
MONITOR
KEYBOARD
Figure 12. WAN Box-To-Box Connection (Transmitter, Receiver, Spectra, Genex)
20 C2907M-D (4/05)
CLOVIS
SERVER
1 OR MORE PCs
VIDEOVIDEO
ROUTER
HUB
Video In
CAMERA
•••••••••••
75
Audio I/O
COM2: RS232
BROWSER
1 OR MORE PCs
ROUTER
HUB
NEW YORK
SERVER
COM1:
RS232/422/485
TRANSMITTER
Power
Figure 13. WAN Browser-To-Box Connection (Transmitter, Browser, Fixed Camera)
CLOVIS
SERVER
1 OR MORE PCs
VIDEOVIDEO
ROUTER
HUB
Video In
SPECTRA
•••••••••••
75
Audio I/O
COM2: RS232
1 OR MORE PCs
ROUTER
HUB
NEW YORK
SERVER
COM1:
RS232/422/485
TRANSMITTER
Power
BROWSER
Figure 14. WAN Browser-To-Box Connection (Transmitter, Browser, Spectra)
C2907M-D (4/05) 21
CLOVIS
SERVER
GENEX
1 OR MORE PCs
•••••••••••
ROUTER
HUB HUB
HUB
75
Video In
Audio I/O
VIDEO
DATA
COM2: RS232
1 OR MORE PCs
ROUTER
HUB
NEW YORK
SERVER
COM1:
RS232/422/485
TRANSMITTER
Power
GENEX
VIDEO
Video In
SPECTRA
BROWSER
Figure 15. WAN Browser-To-Box Connection (Transmitter, Browser, Spectra, Genex)
TRANSMITTER
75
SPECTRA
DATA
Audio I/O
COM2: RS232
COM1:
RS232/422/485
Power
ETHERNET CONNECTION
TO NETWORK (LAN/WAN)
12 VAC
RX-
RX+
TX-
RX-
TX+
RX+
12 V
GND
PV140
4 3 2 1
STRAIGHT
CABLE
PELCO KEYBOARD
KBD200A/ KBD300A
5 6 7 8
12VDC
PC
WORKSTATION
Figure 16. Connection with Pelco Keyboard Control Through a PC (Example Shown with Spectra and Genex)
22 C2907M-D (4/05)

Hardware Installation

Refer to Appendix A for examples of how to connect equipment.

MOUNTING THE NET350 TO THE WALL

Figure 17. Securing NET350 to Wall Mount Bracket
If desired, the NET350 can be mounted to a wall using the supplied wall mount bracket. To do so:
1. Pry off the clear plastic feet from the bottom of the NET350 unit. (Note the grooves on the underside of the unit. They are involved later in securing the unit to the wall mount bracket.)
2. Refer to Figure 17. Align the grooves on the underside of the NET350 with the four smaller holes in the mount. Install four screws (supplied) through the holes in the bottom of the wall mount. The screws fit in the grooves. Tighten carefully to secure the NET350 to the wall mount. DO NOT OVER-TIGHTEN; the screws can damage the aluminum grooves.
3. Attach the mount to the wall with four screws (customer supplied) through the mount’s oblong holes. The mount can be attached to the wall with any side of the NET350 pointing up.

CONNECTING VIDEO SOURCES OR DISPLAYS

The BNC Video In socket of the NET350T transmitter accepts color or black-white sources and automatically detects whether it is PAL or NTSC. The video input has an external switch for termination of 75 ohms.
The Video Out BNC socket of the NET350R receiver can be connected to any PAL or NTSC video monitor or VCR with a composite PAL or NTSC input. You must select NTSC or PAL on the configuration page for video decoder settings for the NET350R.
If the video signal is not looped through, terminate the video input by setting the “75 transmitter) to the right.
Ω ” slide switch (located on the front of the
C2907M-D (4/05) 23

CONNECTING DATA TERMINALS

The bidirectional data interface ports can be used as control ports for equipment connected to the NET350 (for example, a dome camera with motorized lens).
The COM1: RS232/422/485 port supports RS-232, RS-422, and RS-485 transmission protocols.
The COM2: RS232 port supports RS-232 transmission protocols.
PIN ASSIGNMENTS
1234 5
6789
Pin
1 DCD (data carrier detect)
2 RX (receive data) RX+ (receive data plus) RX (receive data)
3 TX (transmit data) TX- (transmit data minus) TX (transmit data)
4 DTR (data terminal ready)
5 GND (ground) GND (ground) GND (ground)
6 DSR (data set ready)
7 RTS (ready to send) TX+ (transmit data plus)
8 CTS (clear to send) RX- (receiver data minus)
9 –––
NOTE: Transmission of transparent data is only possible when a video connection has been established.
RS-232 RS-422/485 RS-232
Table A. Pin Assignments
COM1 COM2
WARNING: Pay attention to documentation relating to the installation and operation of the equipment being controlled.

CONNECTING AUDIO EQUIPMENT

The NET350 provides an audio channel through the Audio I/O jack. The audio signals are transmitted bidirectionally and simultaneously with the video signals. This allows control of a loudspeaker or door intercom system as required. Bidirectional, full duplex audio applies to box-to-box connections only.
1. Connect a preamplified microphone (monaural line) to the Audio I/O jack on the transmitter.
2. Connect a loudspeaker to the Audio I/O jack on the receiver.
GND
Figure 18. Connecting Audio Equipment
Out
In
24 C2907M-D (4/05)

CONNECTING AN ALARM

The NET350 has an alarm input that lets you connect an external signaling device, such as a door contact or motion detector. (Note that there is no motion alarm on a NET350 receiver.) If configured accordingly, an alarm trigger can also set up an automatic connection between the NET350 and the remote station. You can connect switches or contacts directly without a separate power supply.
Do the following to connect an external sensor. Refer to Figure 19.
1. Pull the Alarm I/O terminal block from its plug-in base.
2. Attach conductors to the alarm input and ground conductor terminals. (Insert a small screwdriver tip in the square hole and push hard enough to open the corresponding round hole. Insert the wire in the round hole.)
3. Push the terminal block back on to the plug-in base.
ALARM IN
30 VDC
800 mA MAX.
ALARM OUT
GND
ALARM OUT
ANALOG IN (NOT USED)
POWER OUT, 3.3 VDC 50 mA
GND
GND
Figure 19. Alarm and Relay Connections
C2907M-D (4/05) 25

CONNECTING A RELAY

The NET350 has a relay for switching an external device (for example, a light or siren). The relay can be operated from a control page during an active connection or automatically to coincide with certain events. Settings for the relay must be configured (refer to the Configuration section).
Do the following to connect a peripheral device (such as a light) that can be activated from a PelcoNet live video page. Refer to Figure 19.
WARNING: The maximum rating of the relay contact is 30 VDC and 1 A.
1. Pull the Alarm I/O terminal block from its plug-in base.
2. Connect the Alarm Out terminal on the top of the block to an external power source and the component to be activated (for example, a light or buzzer). Then use the second wire to connect the Alarm Out terminal on the bottom of the block to the external power source and the component. (Insert a small screwdriver tip in the square hole and push hard enough to open the corresponding round hole. Insert the wire in the round hole.)
3. Push the terminal block back on to the plug-in base.

CONNECTING TO A LAN

Refer to Figure 20. You can connect the NET350 to a 10/100BASE-T network either directly or through a hub. To do so, plug a standard Cat5 UTP cable with RJ-45 connectors into the NET350’s Ethernet socket.

SWITCHING ON POWER

There is no power switch—the unit is ready for operation when it is plugged into an outlet. Do not connect the NET350 to a power source until all other connections have been made.
1. Plug the supplied cable into the NET350’s Power socket.
2. Plug the adapter end into an outlet grounded to earth.
The Power LED is red during start-up and turns green when the NET350 is ready to operate. If the network connection is established correctly, the L LED turns green. A flashing yellow T LED means data is moving over the network.
Compact Flash
Alarm I/O
Figure 20. Connecting to the LAN Port
Ethernet Power
LTOI
26 C2907M-D (4/05)
Configuration

BOX-TO-BOX CONNECTION

The following explains a box-to-box connection.
1. First, transmitter and receiver need to be configured appropriately. If the units are supposed to be operated in different subnets, a gateway IP address must be configured. Use the Live video receiver IP address field to address the destination. Enter the settings using either a terminal program or a web browser.
2. Once all addresses are configured, under the terminal program menu, go into the “Rcp+” menu and type e to make the connection. Or program the live video receive IP address and enable the live auto connect setting through the web browser. Make sure the unit that will initiate the connection has an alarm IP address that points to the destination unit. After a few seconds, video transmission begins and the camera scene appears on the monitor attached to the receiver.
Instead of using a terminal program or web browser for establishing a connection, you can attach a contact to the alarm input. Make sure the alarm input field on the configuration page for alarm settings is enabled and the connect on alarm field is turned on.
You can use a web browser to connect to either of the two units, even during an active box-to-box connection. This way you can make changes to the configuration and immediately see the result of the setting (for example, when changing video quality). (This is not true for passwords, however.) If you are connected to the transmitter, the camera pictures are sent to the receiver and web browser simultaneously. There will be a short break in the video display on the receiver monitor whenever the web browser requests a new frame. This is especially noticeable with the Server Push feature.
Transparent data is always transmitted automatically between the two units as soon as the connection becomes active. Data bytes entering the interface are transported to the other end transparently. There is no flow control mechanism for the data channel. Overflowing the serial interface will cause data loss.
To sever the connection from either end, in the “Rcp+” menu press 3 (or disable the alarm).

CONFIGURATION TYPES

There are two ways to configure your system:
•A convenient, complete configuration and display of video is accomplished through the built-in HTTP server, which connects to any standard web browser (for example, Internet Explorer). You can then configure using screens and menus. This is the recommended method. Refer to the Configuration Using a Web Browser section.
The most basic configuration is accomplished by connecting a PC to the RS-232 terminal port. You then type in commands and parameters. Refer to the Configuration Using a Terminal Program section.

CONFIGURATION USING A WEB BROWSER

To use a web browser the system features a complete HTTP server.
Microsoft’s Internet Explorer 5.5 or higher is the recommended browser.
In order for live video images to be decoded, the special ActiveX control file must be installed on your PC. The latest version of the ActiveX platform comes on the PelcoNet CD. Also, the unit will not function without some form of Microsoft’s Virtual Machine installed on the PC. Virtual Machine is included on the PelcoNet resource CD that came with your NET350 unit.
C2907M-D (4/05) 27
GETTING STARTED
NOTES:
NET-Manager is a program that can make it easier to manage PelcoNet units in local networks. The program and manual (C2901M) are on the resource CD that comes with your PelcoNet unit. Refer to the manual for instructions.
The only NET-Manager features available to the NET350 include scanning to see your units’ IP and MAC addresses, changing IP addresses, and viewing the setup pages with the browser.
1. Start your web browser.
2. Connect to the URL http://IP-Address, where IP Address is the IP address of the unit you want to configure. Use the standard dot-
separated format (x.x.x.x) to enter the address. The home page is displayed along with the video from the camera.
Figure 21. PelcoNet Home Page
The home page is the starting point for any configuration.
The window in the left of the screen is the display area for decoded video.
Clicking the Pelco logo on any page connects you to the Pelco Internet home page, provided the LAN supports Internet access.
Click Video 1 or Video 2 to choose which live display to view.
Click Server Push for periodically updated stills.
Click Control to access an options screen with links to pages where you can see and control the displayed view. (Refer to the Web Browser Control Pages section.)
Click Setup to access an options screen with links to configuration pages. Click any icon on the side or the text itself to transfer to the desired page.
28 C2907M-D (4/05)
Loading...
+ 64 hidden pages