Pelco c2626M User Manual

INSTALLATION
SX8205R Unmanaged
®
Ethernet Switch
Five 10BASE-T/100BASE-TX Ports
C2626M (2/07)

Contents

Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Appendix. RJ-45 Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Optional Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Setting 10BASE-T/100BASE-TX Port Modes of Operation. . . . . . . . . . . . . . . . . . . . . . . 10
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Mounting the SX8205R Module into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Mounting the SX8205R Module to a Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
List of Illustrations
1 SX8205R Single-Switch and Multiple-Switch Applications. . . . . . . . . . . . . . . . . . . . . . . 6
2 Front Panel of SX8205R Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 Rear Panel of SX8205R Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 TX Mode Switches for 10BASE-T/100BASE-TX Ports 1-5 . . . . . . . . . . . . . . . . . . . . . . . 10
5 Mounting the SX8205R Module Using the Wall Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6 SX8205R Module Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
7 RJ-45 MDI/MDI-X Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
List of Tables
A TX Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
B Troubleshooting with Front-Panel Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
C Troubleshooting with Rear-Panel Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
D RJ-45 MDI/MDI-X Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
2 C2626M (2/07)

Important Safety Instructions

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Use only installation methods and materials capable of supporting four times the maximum specified load.
18. A CCC-approved power cord must be used to power this equipment when used in China.
19. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
C2626M (2/07) 3
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
4 C2626M (2/07)

Regulatory Notices

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
C2626M (2/07) 5

Product Overview

DESCRIPTION

The SX8205R unmanaged Ethernet switch provides five 10BASE-T/100BASE-TX ports for the transport of bidirectional Ethernet data. Operating as a single switch in a network, the SX8205R module connects to up to five 10BASE-T/100BASE-TX Ethernet devices. If a larger switched network is needed, multiple SX8205R switches can be connected by allowing a port on each switch to be used as an uplink port. Refer to Figure 1 for illustrations of single-switch and multiple-switch applications.
FIVE 10/100 Mbps
CONNECTIONS
SX8205R
SINGLE-SWITCH APPLICATION
SX8205R
10/100 Mbps
UPLINK
FOUR 10/100 Mbps
CONNECTIONS
SAMPLE OF MULTIPLE-SWITCH APPLICATION
SX8205R
FOUR 10/100 Mbps
CONNECTIONS
Figure 1. SX8205R Single-Switch and Multiple-Switch Applications
Features of the SX8205R Ethernet switch include the following:
Uplink port capability for easy network expansion
User-selectable networking functions on a per-port basis:
Autonegotiation between 10 Mbps and 100 Mbps data rates and between full-duplex
and half-duplex modes
10 Mbps or 100 Mbps Selectable
Full-duplex or half-duplex mode selectable
Enabling/disabling of flow control
Auto MDI/MDI-X (Medium Dependent Interface/Medium Dependent Interface Crossover)
operation
6 C2626M (2/07)
Compliant with IEEE 802.3, 802.3u, and 802.3x standards
10BASE-T/100BASE-TX compatibility with all Pelco
Ethernet devices
Environmentally hardened
Designed to meet NEMA TS 2 and Caltrans traffic signal control equipment standards for
ambient operating temperature, mechanical shock and vibration, humidity with condensation, high-line/low-line voltage conditions, and transient voltage protection
NOTE: Conformal coating is required for operation in environments with relative humidity above 95 percent (condensing).
No performance adjustments required
12 VDC or 24 VAC power supply
Stand-alone and rack-mountable modular design
LED indicators for monitoring of 10BASE-T/100BASE-TX port status and operating power
®
and third-party 10BASE-T/100BASE-TX

MODELS

SX8205R* Unmanaged Ethernet switch, five 10BASE-T/100BASE-TX ports
*The conformal coated version of SX8205R is CX8205R.

OPTIONAL ACCESSORIES

The following optional accessories are available:
WM5001-3U Wall mount base kit for single-width module
WM5001-3UEXP Wall mount expansion kit for single-width module
RK5000-3U 19-inch rack mount chassis for 14 slots (no power), 3 RUs
RK5000PS-3U 19-inch rack mount chassis for 12 slots with power, 3 RUs
EPS5000-120 External rack power supply, 1 RU, dual 120 W power outputs
RK5001B-3U Blank filler panel, single width
RK5002B-3U Blank filler panel, double width
RK5001-1UEXP Adapter kit that allows a 3 RU single-width module to be used in RK5000PS-5U
rack mount chassis
C2626M (2/07) 7

FRONT PANEL

Figure 2 illustrates the front panel of the SX8205R module.
Figure 2. Front Panel of SX8205R Module
ì
Reset Button: Restarts the unit
î Power LED: Pelco badge
NOTE: For additional information about the Power LED, refer to Troubleshooting on page 15.
8 C2626M (2/07)
Loading...
+ 16 hidden pages