Pelco c2626M User Manual

INSTALLATION
SX8205R Unmanaged
®
Ethernet Switch
Five 10BASE-T/100BASE-TX Ports
C2626M (2/07)

Contents

Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Appendix. RJ-45 Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Optional Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Setting 10BASE-T/100BASE-TX Port Modes of Operation. . . . . . . . . . . . . . . . . . . . . . . 10
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Mounting the SX8205R Module into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Mounting the SX8205R Module to a Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
List of Illustrations
1 SX8205R Single-Switch and Multiple-Switch Applications. . . . . . . . . . . . . . . . . . . . . . . 6
2 Front Panel of SX8205R Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 Rear Panel of SX8205R Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 TX Mode Switches for 10BASE-T/100BASE-TX Ports 1-5 . . . . . . . . . . . . . . . . . . . . . . . 10
5 Mounting the SX8205R Module Using the Wall Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6 SX8205R Module Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
7 RJ-45 MDI/MDI-X Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
List of Tables
A TX Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
B Troubleshooting with Front-Panel Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
C Troubleshooting with Rear-Panel Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
D RJ-45 MDI/MDI-X Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
2 C2626M (2/07)

Important Safety Instructions

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Use only installation methods and materials capable of supporting four times the maximum specified load.
18. A CCC-approved power cord must be used to power this equipment when used in China.
19. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
C2626M (2/07) 3
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
4 C2626M (2/07)

Regulatory Notices

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
C2626M (2/07) 5

Product Overview

DESCRIPTION

The SX8205R unmanaged Ethernet switch provides five 10BASE-T/100BASE-TX ports for the transport of bidirectional Ethernet data. Operating as a single switch in a network, the SX8205R module connects to up to five 10BASE-T/100BASE-TX Ethernet devices. If a larger switched network is needed, multiple SX8205R switches can be connected by allowing a port on each switch to be used as an uplink port. Refer to Figure 1 for illustrations of single-switch and multiple-switch applications.
FIVE 10/100 Mbps
CONNECTIONS
SX8205R
SINGLE-SWITCH APPLICATION
SX8205R
10/100 Mbps
UPLINK
FOUR 10/100 Mbps
CONNECTIONS
SAMPLE OF MULTIPLE-SWITCH APPLICATION
SX8205R
FOUR 10/100 Mbps
CONNECTIONS
Figure 1. SX8205R Single-Switch and Multiple-Switch Applications
Features of the SX8205R Ethernet switch include the following:
Uplink port capability for easy network expansion
User-selectable networking functions on a per-port basis:
Autonegotiation between 10 Mbps and 100 Mbps data rates and between full-duplex
and half-duplex modes
10 Mbps or 100 Mbps Selectable
Full-duplex or half-duplex mode selectable
Enabling/disabling of flow control
Auto MDI/MDI-X (Medium Dependent Interface/Medium Dependent Interface Crossover)
operation
6 C2626M (2/07)
Compliant with IEEE 802.3, 802.3u, and 802.3x standards
10BASE-T/100BASE-TX compatibility with all Pelco
Ethernet devices
Environmentally hardened
Designed to meet NEMA TS 2 and Caltrans traffic signal control equipment standards for
ambient operating temperature, mechanical shock and vibration, humidity with condensation, high-line/low-line voltage conditions, and transient voltage protection
NOTE: Conformal coating is required for operation in environments with relative humidity above 95 percent (condensing).
No performance adjustments required
12 VDC or 24 VAC power supply
Stand-alone and rack-mountable modular design
LED indicators for monitoring of 10BASE-T/100BASE-TX port status and operating power
®
and third-party 10BASE-T/100BASE-TX

MODELS

SX8205R* Unmanaged Ethernet switch, five 10BASE-T/100BASE-TX ports
*The conformal coated version of SX8205R is CX8205R.

OPTIONAL ACCESSORIES

The following optional accessories are available:
WM5001-3U Wall mount base kit for single-width module
WM5001-3UEXP Wall mount expansion kit for single-width module
RK5000-3U 19-inch rack mount chassis for 14 slots (no power), 3 RUs
RK5000PS-3U 19-inch rack mount chassis for 12 slots with power, 3 RUs
EPS5000-120 External rack power supply, 1 RU, dual 120 W power outputs
RK5001B-3U Blank filler panel, single width
RK5002B-3U Blank filler panel, double width
RK5001-1UEXP Adapter kit that allows a 3 RU single-width module to be used in RK5000PS-5U
rack mount chassis
C2626M (2/07) 7

FRONT PANEL

Figure 2 illustrates the front panel of the SX8205R module.
Figure 2. Front Panel of SX8205R Module
ì
Reset Button: Restarts the unit
î Power LED: Pelco badge
NOTE: For additional information about the Power LED, refer to Troubleshooting on page 15.
8 C2626M (2/07)

REAR PANEL

Figure 3 illustrates the rear panel of the SX8205R module.
Figure 3. Rear Panel of SX8205R Module
ì Rack Power/Alarm Connector: 4-pin connector for power/alarm connection of rack-
mounted module
î Stand-Alone Power Connector: 2-pin connector for power connection of stand-alone
module; removable mating connector with screw terminals (not shown)
ï
10BASE-T/100BASE-TX Ports 1-5: RJ-45 connectors
ñ
RJ-45 10BASE-T/100BASE-TX Port Status LED, Left: Link/activity status indicator
ó
RJ-45 10BASE-T/100BASE-TX Port Status LED, Right: Duplex mode/collision indicator
For additional information about rear-panel connections, refer to Installation on page 10. For detailed information about the RJ-45 LEDs, refer to Troubleshooting on page 15.
C2626M (2/07) 9

Installation

PACKAGE CONTENTS

The following items are supplied:
1 SX8205R module
1 Regulated switching power supply with four plug adapters (North American, Australian, U.K.,
and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output
1 Wall clip with two 4-40 x 0.250-inch Phillips pan head screws with lock washers (for attachment
of single module to wall)
1 SX8205R Unmanaged Ethernet Switch Installation manual (this manual)

SETTING 10BASE-T/100BASE-TX PORT MODES OF OPERATION

NOTE: As a matter of convenience, it is recommended that you verify the modes of operation for
each 10BASE-T/100-BASE-TX port and then change the mode settings—if necessary—before mounting the SX8205R module into a rack or onto a wall.
The SX8205R module provides various configuration options that allow you to select the desired modes of operation for each 10BASE-T/100BASE-TX port (ports 1-5). You can select the desired modes of operation by means of a TX Mode switch that is provided on the bottom of the module for each port (refer to Figure 4).
TX MODE SWITCHES - PORTS 1-5
TX Mode
Figure 4. TX Mode Switches for 10BASE-T/100BASE-TX Ports 1-5
10 C2626M (2/07)
Using the TX Mode switch for a particular port, you can do the following:
Enable autonegotiation or select (force) a specific data rate and duplex mode:
Enabling autonegotiation allows the SX8205R module to automatically negotiate with
the device to which the port is connected for data rate and duplex modes of operation: 10 Mbps or 100 Mbps data rate and half-duplex or full-duplex mode. The highest common denominator of operational modes is automatically selected.
Autonegotiation is enabled by default.
If autonegotiation is not desired, you can select a specific data rate and duplex mode:
Data rate configuration allows you to select 10 Mbps or 100 Mbps.
Duplex mode configuration allows you to select half-duplex mode or full-duplex
mode.
Enable or disable flow control. Flow control controls data transmission at the sending device to avoid overfilling buffers and losing data at the receiving device. When the buffers on the receiving device are full, a message is sent to the sending device to suspend the transmission until the data in the buffers has been processed.
NOTE: For time-sensitive data applications (for example, video and audio applications), it is recommended that flow control be disabled.
Flow control is disabled by default.
With the SX8205R module powered off, set each TX Mode switch to the desired modes of operation. Refer to Table A for TX Mode switch settings and corresponding 10BASE-T/100BASE-TX port modes of operation. Note that each 10BASE-T/100BASE-TX port operates independently of one another; therefore, each port can be set to different modes of operation as appropriate.
Tab l e A. TX Mode Switch Settings
TX Mode
Switch Position 10BASE-T/100BASE-TX Modes of Operation
0 Auto Neg/Dis FC: Enables autonegotiation between 10 Mbps and
100 Mbps and between half-duplex and full-duplex modes, disables flow control (default setting)
1 100 FD/Dis FC: Selects 100 Mbps full-duplex, disables flow control
2 100 HD/DIS FC: Selects 100 Mbps half-duplex, disables flow control
3 10 FD/Dis FC: Selects 10 Mbps full-duplex, disables flow control
4 10 HD/Dis FC: Selects 10 Mbps half-duplex, disables flow control
5 Auto Neg/En FC: Enables autonegotiation between 10 and 100 Mbps
and between half-duplex and full-duplex modes, enables flow control
6 100 FD/En FC: Selects 100 Mbps full-duplex, enables flow control
7 100 HD/En FC: Selects 100 Mbps half-duplex, enables flow control
8 10 FD/En FC: Selects 10 Mbps full-duplex, enables flow control
9 10 HD/En FC: Selects 10 Mbps half-duplex, enables flow control
NOTE: Switch positions 0-4 disable flow control. Positions 5-9 enable flow control.
C2626M (2/07) 11
NOTE: TX Mode configuration must be set when the module is powered off. If you wish to change a TX Mode switch setting after the module has been powered on, power off the module, change the TX Mode switch setting, and then power on the module again.

MOUNTING

The SX8205R module can be mounted into a rack or can be used as a stand-alone module. As a stand­alone module, the unit can be placed on a desktop or can be mounted to a wall.
NOTE: As a matter of convenience, it is recommended that you set the modes of operation for each 10BASE-T/100-BASE-TX port—if required—before mounting the SX8205R module into a rack or onto a wall. For information about setting the port modes of operation, refer to Setting 10BASE-T/ 100BASE-TX Port Modes of Operation on page 10.

MOUNTING THE SX8205R MODULE INTO A RACK

The SX8205R module can be installed into an RK5000 Series rack mount chassis, which can be mounted into an industry-standard 19-inch (48.26 cm) equipment rack. The RK5000 Series rack mount chassis includes the following models:
RK5000PS-3U and RK5000-3U: Designed to accommodate fiber optic modules as follows:
The RK5000PS-3U rack mount chassis provides 12 single-width module slots and a
power supply.
The RK5000-3U rack mount chassis provides 14 single-width module slots (a power
supply is not included). Power to the modules can be supplied using the optional external power supply (EPS5000-120).
For additional information, refer to the RK5000PS-3U/RK5000-3U Fiber Rack Mount Chassis Installation manual.
RK5000PS-5U: Designed to accommodate Endura optic modules and the SX8205R module with the use of the appropriate adapter kit. The RK5001-1UEXP adapter kit is required for installation of the SX8205R module into the RK5000PS-5U chassis.
modules but can also accommodate fiber

MOUNTING THE SX8205R MODULE TO A WALL

The SX8205R module can be mounted to a wall in the following ways:
Using the supplied wall clip for attachment of a single module to a wall. For installation instructions, refer to Mounting the SX8205R Module Using the Wall Clip on page 13.
Using the optional WM5001 wall mount kits, which are designed for mounting of single-width fiber optic modules. The WM5001-3U base kit allows mounting of a single module to a wall. The WM5001-3UEXP expansion kit allows mounting of an additional module. It is recommended that a maximum of three expansion kits be used with the base kit, allowing a maximum of four single-width modules to be mounted to a wall.
NOTE: The WM5001 wall mount kits can be used with the WM5002 wall mount kits, which are designed for mounting of double-width fiber optic modules. If mounting a mix of single-width and double-width modules is desired, it is recommended that a maximum of two single-width modules and one double-width module be mounted in combination with one another.
For mounting instructions using the wall mount kits, refer to the WM5000 Series Wall Mount Kit Installation manual.
12 C2626M (2/07)
Mounting the SX8205R Module Using the Wall Clip
NOTE: Before mounting the SX8205R module to a wall, ensure that there is adequate space at both
ends for viewing the front-panel Power LED and for making the various rear-panel cable connections.
To attach the SX8205R module to a wall using the supplied wall clip, refer to Figure 5 and do the following:
1. Using the two vertical or horizontal wall-mounting holes, attach the wall clip to a wall using two screws (not provided).
2. Slide the module into the clip until the two holes on the bottom of the module align with the two holes on the lower flange of the clip.
3. Attach the module to the clip using the two Phillips pan head screws provided for the clip.
UPPER FLANGE
VERTICAL MOUNTING HOLE (2)
HORIZONTAL MOUNTING HOLE (2)
SCREW, PHILLIPS PAN HEAD WITH LOCK WASHER (2)
WALL CLIP
LOWER FLANGE
Figure 5. Mounting the SX8205R Module Using the Wall Clip
C2626M (2/07) 13

CONNECTIONS

Connections to the SX8205R module are made on the rear panel of the module (refer to Figure 6).
POWER/ALARM CONNECTION FOR RACK-MOUNTED MODULE
POWER CONNECTION FOR STAND-ALONE MODULE
10/100 NETWORK CABLE
10/100 NETWORK CABLE
10/100 NETWORK CABLE
10/100 NETWORK CABLE
10/100 NETWORK CABLE
Figure 6. SX8205R Module Connections
As illustrated in Figure 6, SX8205R module connections consist of the following:
Power connection
NOTES:
A 12 VDC or 24 VAC power supply can be used to power the module when used as a
stand-alone unit. A 12 VDC power supply is provided. If a 24 VAC power supply is used, the power supply must be a Listed Direct Plug-In Power Unit marked as Class 2 and rated as 24 VAC, 0.50 A (minimum output).
In extreme temperature conditions, it is recommended that an industrial-rated outdoor
power supply such as the Pelco WCS1-4 power supply be used.
10BASE-T/100BASE-TX connections
NOTES:
Use Cat5e or a higher category of cable to connect to a 10BASE-T/100BASE-TX port.
Cable length must not exceed 328 feet (100 meters).
The 10BASE-T/100BASE-TX ports are auto MDI/MDI-X ports; therefore, either a
straight-through or crossover cable can be used. The ports automatically detect the cable type that is used. Refer to Appendix. RJ-45 Connector Pinouts on page 22 for pinout information.
14 C2626M (2/07)

Troubleshooting

LED indicators on the front and rear panels of the SX8205R module allow you to monitor operational status:
The Power LED (Pelco badge) on the front panel (refer to Figure 2) allows you to monitor operating power. Refer to Table B for information about the Power LED and associated troubleshooting guidelines.
LED indicators on the rear panel (refer to Figure 3) allow you to monitor RJ-45 10BASE-T/ 100BASE-TX port status. Refer to Table C for information about the rear-panel indicators and associated troubleshooting guidelines.
Indicator Color Meaning Possible Cause Corrective Action
Blue Power is being
Not lit Power is not being
Table B. Troubleshooting with Front-Panel Indicator
Power LED (Pelco badge)
No action required. applied to the module.
Power connection is faulty. Check power connection. applied to the module.
Power supply has failed. Replace power supply.
Loss of power occurs due to
tripped circuit breakers,
blown fuses, or faulty elec-
trical service.
If module is rack mounted, reseat module or power supply as necessary.
Check circuit breakers, fuses, or electrical service as necessary.
C2626M (2/07) 15
Table C. Troubleshooting with Rear-Panel Indicators
Indicator Color Meaning Possible Cause Corrective Action
RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity)
Amber A 10BASE-T link is
established.
If 10BASE-T operation is
desired, no action is required. If 10BASE-T operation is not desired, refer to Setting
10BASE-T/100BASE-TX Port Modes of Operation on
page 10 for information.
Flashing amber Data activity is
occurring on the 10BASE-T link; data is being transmitted or received.
If 10BASE-T operation is
desired, no action is required. If 10BASE-T operation is not desired, refer to Setting
10BASE-T/100BASE-TX Port Modes of Operation on
page 10 for information.
Green A 100BASE-TX link
is established.
If 100BASE-TX operation is
desired, no action is required. If 100BASE-TX operation is not desired, refer to Setting
10BASE-T/100BASE-TX Port Modes of Operation on
page 10 for information.
Flashing green Data activity is
occurring on the 100BASE-TX link; data is being trans­mitted or received.
If 100BASE-TX operation is
desired, no action is required. If 100BASE-TX operation is not desired, refer to Setting
10BASE-T/100BASE-TX Port Modes of Operation on
page 10 for information.
(Continued on next page)
16 C2626M (2/07)
Tab l e C. Troubleshooting with Rear-Panel Indicators (Continued)
Indicator Color Meaning Possible Cause Corrective Action
RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued)
Not lit A 10BASE-T or
100BASE-TX link cannot be established.
A problem may exist with the cable:
Cable is not connected to the module or to the 10BASE-T/100BASE-TX compatible device.
Cable is defective.
Cable is not the proper
cable type.
Do any of the following as applicable:
Connect the cable.
Replace the cable. Use
Cat5e or higher cable.
Ensure that cable is proper length. Cable length must not exceed 328 feet (100 meters).
Cable is not the proper length.
Device connected to the module is not powered on.
Duplex mode setting (half­duplex or full-duplex) does not match the duplex mode setting of the remote module.
Power on the device connected to the module.
Set the duplex mode setting on modules to match one another (autonegotiation or forced half­duplex or full-duplex). Refer to
Setting 10BASE-T/ 100BASE-TX Port Modes of Operation on page 10 for
information.
Port on module is defective. Replace the module.
(Continued on next page)
C2626M (2/07) 17
Tab l e C. Troubleshooting with Rear-Panel Indicators (Continued)
Indicator Color Meaning Possible Cause Corrective Action
RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision)
Amber Port is set to
10BASE-T full­duplex mode.
If 10BASE-T full-duplex
operation is desired, no action is required. If 10BASE-T full­duplex operation is not desired, refer to Setting
10BASE-T/100BASE-TX Port Modes of Operation on
page 10 for information.
Flashing amber Port is set to
10BASE-T half­duplex mode and network collision has occurred.*
Normal or excessive colli­sions occur on a half-duplex link.*
If a normal collision occurs, no action is required. If a problem with the network exists due to excessive colli­sions, do any of the following as appropriate:
If half-duplex mode is not required, set the TX Mode switch to full-duplex mode by means of autonegotia­tion or by forcing the mode (refer to Setting 10BASE-T/
100BASE-TX Port Modes of Operation on page 10 for
information).
If half-duplex mode is
required, do any of the following as applicable:
– Replace network cable
if it is defective or if it is not the proper cable type. Use Cat5e or higher cable.
– Ensure that cable is
proper length. Cable length must not exceed 328 feet (100 meters).
– Replace the network
interface card (NIC) if it is defective or if it is incompatible.
– Segment the network.
(Continued on next page)
18 C2626M (2/07)
Tab l e C. Troubleshooting with Rear-Panel Indicators (Continued)
Indicator Color Meaning Possible Cause Corrective Action
RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision) (Continued)
Green Port is set to
100BASE-TX full­duplex mode.
If 100BASE-TX full-duplex
operation is desired, no action is required. If 100BASE-TX full­duplex operation is not desired, refer to Setting
10BASE-T/100BASE-TX Port Modes of Operation on
page 10 for information.
Flashing green Port is set to
100BASE-TX half­duplex mode and network collision has occurred.*
Normal or excessive colli­sions occur on a half-duplex link.*
If a normal collision occurs, no action is required. If a problem with the network exists due to excessive collisions, do any of the following as appropriate:
If half-duplex mode is not
required, set the TX Mode switch to full-duplex mode by means of autonegotia­tion or by forcing the mode (refer to Setting 10BASE-T/
100BASE-TX Port Modes of Operation on page 10 for
information).
If half-duplex mode is
required, do any of the following as applicable:
– Replace cable if it is
defective or if it is not the proper cable type. Use Cat5e or higher cable.
– Ensure that cable is the
proper length. Cable length must not exceed 328 feet (100 meters).
– Replace the network
interface card (NIC) if it is defective or if it is incompatible.
– Segment the network.
(Continued on next page)
C2626M (2/07) 19
Tab l e C. Troubleshooting with Rear-Panel Indicators (Continued)
Indicator Color Meaning Possible Cause Corrective Action
RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision) (Continued)
Not lit Port is set to
10BASE-T half­duplex mode and no collisions are detected.*
If 10BASE-T half-duplex
operation is desired, no action is required. If 10BASE-T half­duplex operation is not desired, refer to Setting
10BASE-T/100BASE-TX Port Modes of Operation on
page 10 for information.
*A collision is a normal event on a half-duplex Ethernet link. A collision occurs when two or more devices,
referred to as stations, attempt to transmit at the same time on a shared physical medium.
Ethernet uses the CSMA/CD (Carrier Sense Multiple Access/Collision Detect) media access method by which two or more stations share a common transmission medium. Using CSMA/CD, a station monitors the medium and transmits a message in bit-serial form when it senses that no other station is transmitting. If, after initiating a transmission, the message collides with that of another station, each transmitting station then intentionally transmits for an additional predefined period to ensure propagation of the collision throughout the system. To avoid another collision, each station waits a random amount of time (backoff) before attempting to transmit again.
Excessive collisions occur when retransmission of a frame fails after 16 consecutive times and the frame is dropped. Excessive collisions may indicate that the network is becoming congested.
20 C2626M (2/07)

Specifications

PERFORMANCE
Switch Type Unmanaged Layer 2 Switch Method Store and forward Switch Fabric Non-head-of-line blocking Data Rate 10/100 Mbps Compliance IEEE 802.3, 802.3u, 802.3x Interface Auto MDI/MDI-X Operating Mode Full-duplex or half-duplex Address Table Size 1,024 MAC address entries with automatic learning and aging Quality of Service IEEE 802.1p priority, tag-based, 4 queues per port,
Maximum Frame Size Untagged Ethernet frames up to 1,518 bytes
GENERAL
Operating Temperature -40° to 167°F (-40° to 75°C) Input Power Requirements 12 VDC or 24 VAC, 0.50 A LED Indicators Power
Dimensions 8.75" D x 1.08" W x 4.81" H
Unit Weight 1.6 lb (0.73 kg)
MECHANICAL
Connectors
Rack Power/Alarm 1, 4-pin connector Stand-Alone Power 1, 2-pin connector, screw terminal Electrical 5, RJ-45, 10BASE-T/100BASE-TX
weighted fair queuing scheduling
Tagged Ethernet frames up to 1,522 bytes
10BASE-T/100BASE-TX port status (2 LEDs per port: link/activity and speed, duplex/collision and speed)
(22.23 x 2.74 x 12.22 cm)
C2626M (2/07) 21

Appendix. RJ-45 Connector Pinouts

Figure 7 illustrates RJ-45 MDI/MDI-X connector pinouts.
MDI (NORMAL MODE) MDI-X (CROSSED MODE)
8
7
TX-
TX+ RX­RX+
6
5
4
3
2
1
RX-
RX+ TX­TX+
Figure 7. RJ-45 MDI/MDI-X Connector Pinouts
Table D summarizes RJ-45 MDI/MDI-X connector pinouts.
Table D. RJ-45 MDI/MDI-X Connector Pinouts
MDI
Pin Number
(Normal Mode)
1RX+ TX+
2RX- TX-
3 TX+ RX+
4 Not used Not used
5 Not used Not used
6 TX- RX-
7 Not used Not used
8 Not used Not used
8
7
6
5
4
3
2
1
MDI-X
(Crossed Mode)
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
22 C2626M (2/07)
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, an y merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years on fiber optic products and TW3000 Serie s unshielded twisted pair transmission products.
• Three years on Spectra® IV products.
• Three years on Genex® Series products (multiplexers, server, and keyboard).
• Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3 701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H­2X camera models, which have a five-year war ranty.
• Three years on PMCL200/300/400 Series LCD monit ors.
• Two years on standard motorized or fixed focal length lenses.
• Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.
• Two years on Spectra III™, Esprit®, ExSite™, and PS20 scanners, including when used in continuous motion applications.
• Two years on Esprit and WW5700 Series window wiper (excluding wiper blades).
• Two years (except lamp and color wheel) on Digital Light Processing (DLP®) displays. The lamp and color wheel will be covered for a period of 90 days. The air filter is not covered un der warranty.
• Eighteen months on DX Series digital video recorders, NVR30 0 Series network video recorders, and Endura™ Series distributed network-based video products.
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or prese t lenses used in continuous motion applications (that is, preset scan, tour and auto scan mode s).
Pelco will warrant all replacement p arts and repairs for 90 days from the date of P elco shipment. All goods requiring warranty rep air shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the sp ecific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of an y rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of prof it and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with spe cific legal rights. The Dealer may also have additional right s, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a p roduct which does not fall under the warranty conditions stated above, please include a writte n explanation with the product wh en returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, plea se call the factory at (800) 289-9100 or (559) 292-1981 to obtain an autho rization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge. Goods returned for repair or credit sh ould be clearly identified with the assigned CA or RA number and fr eight should be prepaid. Ship to the appropriate
address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the go ods to:
Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the good s to:
Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933
REVISION HISTORY
Manual # Date Comments
C2626M-BETA 10/06 Beta version. C2626M 2/07 Official release.
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered tr ademarks of Pelco. Endura, ExSite, and Spectra III are trademarks of Pelco. ©Copyright 2007, Pelco. DLP is a registered trademark of Texas Instruments, Inc. All rights reserved.
®
Worldwide Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada Tel: 800/289-9100 Fax: 800/289-9150
International
Tel: 1-559/292-1981