Pelco c2462m-e User Manual

INSTALLATION
090 Series Camclosure Indoor Integrated
Camera System
Surface Mount/In-Ceiling
®
C2462M-E (3/09)

Contents

Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Regulatory Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Remove the Dome Bubble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Surface Installation: Ceiling/Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
In-Ceiling Installation: Suspended Ceiling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
In-Ceiling Installation: Fixed Ceiling OR Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Surface Installation: 4S Standard Electrical Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
In-Ceiling Installation: 4S Deep Electrical Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Camera Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Camera Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Fixed Focal Length Lens Without Auto Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Focus Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Vertical Phase Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Adjusting the Phase Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Install Liner and Bubble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Dome Liner Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Dome Bubble Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Service Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

List of Illustrations

1 Removing the Dome Bubble. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Ceiling/Wall Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 Concrete Ceiling/Wall Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4 Ceiling Tile Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5 How to Remove Surface Mount Ring from Back Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6 In-Ceiling Installation to a Fixed Ceiling or Wall. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
7 4S Standard Electrical Box Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
8 4S Deep Electrical Box Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
9 Positioning the Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
10 ICS090 Series Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
11 Adjusting the Focus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
12 Vertical Phase Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
13 Installing the Dome Liner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
14 Installing the Dome Bubble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
15 Attaching the 2.5 mm Monaural Headphone Plug. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

List of Tables

A Power Input: Surface, Ceiling/Wall Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
B Power Input: In-Ceiling, Suspended Ceiling Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
C Power Input: In-Ceiling, Fixed Ceiling/Wall Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
D Power Input: Surface, 4S Standard Electrical Box Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
E Power Input: In-Ceiling, 4S Deep Electrical Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
C2462M-E (3/09) 3

Important Safety Instructions

1. Installation and servicing should be done only by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to rain and moisture.
3. Use only installation methods and materials capable of supporting four times the maximum specified load.

Regulatory Notices

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve Radio­TV Interference Problems.” This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

Description

The ICS090 Series Camclosure® integrated camera system integrates a camera and lens package in a small, discreet dome. The system is easy to install and can be mounted or recessed to the surface of a ceiling or wall.
Prior to the installation of your new system, thoroughly familiarize yourself manual.

PARTS LIST

The following materials are supplied with the 090 Series Camclosure integrated camera system:
Qty Description
1 Assembled ICS090 Series Camclosure (back box
1 Clear dome bubble
1 Plastic liner
1 Adapter plate
2 Screws, 8-32 x 1.00-inch Phillips pan head
2 Screws, 8-32 x 0.750-inch, self-tapping
2 Screws, 8-32 x 2.50-inch, self-tapping
2 Screws, 10-32 x 1.50-inch, self-tapping
, smoked dome bubble, and camera module)
with the information in this
C2462M-E (3/09) 5

Remove the Dome Bubble

Turn the dome bubble counterclockwise and lift (refer to Figure 1). Place the bubble on a nonabrasive surface.
If the unit is supplied with a dome liner, remove the lin gently lift it from the unit. Place the liner to the side; it will be reinstalled along with the bubble after the installation has been completed following installation.
Figure 1. Removing the Dome Bubble
er before installing the unit. To remove the liner,
6 C2462M-E (3/09)

Installation

The installation methods for the ICS090 Series include the following options:
Mount to the surface of a ceiling or wall
Install in a suspended ceiling
Install in a fixed ceiling or wall
Mount to the surface of a 4S standard electrical box
Install in a 4S deep electrical box

SURFACE INSTALLATION: CEILING/WALL

Refer to Figure 2 on page 8 for the following steps. Refer to Figure 3 on page 8 if you are installing the unit to the surface of a concrete ceiling or wall.
1. Pull the video and power wires through the ceiling/wall.
2. Connect the video cable and wires.
BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.
Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -.
3. Connect the power wires (refer to Ta bl e A).
Tab le A . Power Input: Surface, Ceiling/Wall Installation
Voltage Red Wire Black Wire
12 VDC + Ground
24 VAC
AC operation only: If you a side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.
NOTE: Failure to connect all of the units in the same way will ca with each other, which might produce a vertical roll when switching between cameras.
C2462M-E (3/09) 7
re wiring more than one Camclosure to the same transformer, connect one
use the cameras to be out of phase
4. Use 6-32 toggle bolts (not supplied) to attach the surface mount ring and back box to the mounting surface (refer to Figure 2).
NOTE: For a concrete ceiling or wall installation, use 8-32
mounting hardware (not supplied), refer to
Figure 3.
Figure 2. Ceiling/Wall Installation
Figure 3. Concrete Ceiling/Wall Installation
8 C2462M-E (3/09)