Installation/Operation
150 Series Camclosure
®
Integrated Camera System
C2410M-G (1/04)
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • Pelco Online @ www.pelco.com
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150 • DataFAX (800) 289-9108
International Customers: Tel +1(559) 292-1981 • FAX +1(559) 348-1120 • DataFAX +1(559) 292-0435
[ 2 ] Pelco Manual C2410M-G (1/04)
CONTENTS
Section Page
IMPORTANT SAFEGUARDS AND WARNINGS ..................................................................................... 4
DESCRIPTION ........................................................................................................................................ 4
INSTALLATION ........................................................................................................................................ 4
INSTALL BACK BOX ...................................................................................................................... 4
MOUNTING DIRECTLY TO WALL OR CEILING ................................................................. 4
MOUNTING TO 4S DEEP ELECTRICAL BOX .................................................................... 5
MOUNTING TO CEILING TILE ............................................................................................ 5
INSTALL CAMERA ........................................................................................................................ 5
INSTALL DOME AND TRIM RING ................................................................................................. 7
ADJUSTMENTS (COLOR CAMERA ONLY) ........................................................................................... 7
VERTICAL PHASE (24 VAC OPERATION ONLY) ......................................................................... 7
AUTO IRIS LEVEL ADJUSTMENT ................................................................................................ 8
FOCUS ADJUSTMENT FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS .......................... 8
SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS .............................. 9
SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITHOUT AUTO IRIS ...................... 9
SWITCH SETTINGS FOR VARIFOCAL LENS ............................................................................. 10
SPECIFICATIONS .................................................................................................................................. 10
REGULATORY NOTICES ....................................................................................................................... 11
WARRANTY AND RETURN INFORMATION ......................................................................................... 12
Pelco Manual C2410M-G (1/04) [ 3 ]
IMPORTANT SAFEGUARDS AND WARNINGS
1. Installation and servicing should be done only by qualified service personnel and conform to all local
codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is
designed for indoor use only and must not be installed where exposed to rain and moisture.
3. Use only installation methods and materials capable of supporting four times the maximum specified
load.
4. Use stainless steel hardware to fasten the enclosure to outdoor surfaces.
5. To prevent damage from water leakage when installing an enclosure outdoors, apply sealant around
the bolt holes between the enclosure and mounting surface.
DESCRIPTION
The 150 Series Camclosure® Integrated Camera System is an in-ceiling dome incorporating a camera
and lens package into a small, discreet, high-security enclosure designed for areas subject to heavy
vandalism.
INSTALLATION
1 Install Back Box
Mounting Directly to Wall or Ceiling
1. Cut a hole 3.5 inches (9 cm) in
diameter in the ceiling or wall using
the adapter plate as a template.
2. Connect the video cable.
3. Connect the power wires.
• For 12 VDC, connect the
24 VAC/12 VDC (red) and GND (black)
wires to input power.
• For 24 VAC, connect the 24 VAC/12 VDC (red)
and 24 VAC (blue) wires to input power.
4. Attach the back box to the wall or ceiling.