Pelco C2227M-D, PMCL-CMP User Manual

C2227M-D (8/07) PMCL-CMP Monitor Mount and Telescoping Pole
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Installation should be done only by qualified personnel and conform to all local codes.
7. Only use replacement parts recommended by Pelco.
8. This unit is designed for indoor use only, and it must not be installed where exposed to rain or moisture.
Description
The PMCL-CMP is a ceiling mount and pole that can be used to mount any of Pelco’s 200, 300, or 400 Series flat panel LCD monitors. This mount can also support most sizes of Pelco’s 500 Series LCD monitors, although a PMCL-V100, PMCL-V200, or PMCL-VA adapter plate may be required. The PMCL526 monitor requires the PMCL-V100 adapter and the PMCL532 monitor requires the PMCL-V200 adapter; the adapters are included with the corresponding monitors. The PMCL537 and PMCL542 require the PMCL-VA adapter (not included).
The PMCL-CMP mount can be swiveled 360 degrees to allow you to use your monitor in either landscape or portrait view. The mount also allows you to tilt the monitor 35 degrees for the best viewing angle. The pole telescopes from 15 to 30 inches. This mount can also be used with Pelco’s MRCA ceiling mount. The PMCL-CMP is capable of supporting a maximum load of 90 pounds (40.8 kg).
NOTE: If you are installing a mount using a Pelco adapter (PMCL-V100, PMCL-V200, or PMCL-VA), refer to the manual shipped with the adapter for installation instructions.
Installation
The following parts are supplied:
Qty Description
1 Mounting flange 1 Mounting head 1 Telescoping pole 4 M4 x 10 mm pan head Phillips screws, stainless steel 4 Split lock washers 4 M6 x 12 mm pan head Phillips screws, stainless steel 4Flat washers 1 Allen wrench, 3/16-inch 1 Allen wrench, 3/32-inch
To install the ceiling mount:
NOTE: It is recommended that two people be present when mounting the monitor. One person should hold the monitor, while the second person installs the screws to secure the monitor to the mount.
1. Attach the mounting flange to the ceiling. (Mounting hardware is not supplied.)
a. If installing the mount to a wood beam ceiling, the beam must be at least 2 inches x 4 inches with a maximum 0.5-inch thick layer of
plasterboard. Use the following steps to attach the mounting flange to a wood beam ceiling:
(1) Use a stud finder to locate and mark the edges of the wood beam that the mount will be attached to.
(2) Center the mounting flange between the edges of the beam. Use the mounting flange as a template to mark two mounting holes that are
not adjacent to each other.
(3) Attach the mounting flange to the ceiling using two 1/4 x 2-inch wood screws as shown in Figure 1 on page 2.
b. Use the following steps to attach the mounting flange to a steel I-beam ceiling:
(1) Use the mounting flange as a template to mark the mounting holes on the I-beam.
(2) Attach the mounting flange to the I-beam using 1/4-20 x 1-inch machine screws with nuts as shown in Figure 2. Depending on the size of
the I-beam, machine screws longer than one inch may be required.
c. Use the following steps to attach the mounting flange to a concrete ceiling:
(1) Use the mounting flange as a template to mark the mounting holes on the ceiling.
(2) Attach the mounting flange to the concrete ceiling using 1/4 x 1.75-inch wedge concrete anchors with washers and nuts. Depending on the
thickness of the ceiling, concrete anchors longer than 1.75 inches may be required.
STEEL I-BEAM
NUT/LOCK WASHER
WOOD BEAM
WOOD SCREW
MACHINE SCREWS
Figure 1. Attaching the Mount to Wood Stud Ceiling
2. Adjust the length of the telescoping pole.
a. Remove the locking pin at the center of the pole using a flat
head screwdriver (not supplied).
b. Loosen the locking collar on the pole and slide the pole out to
the desired length. Retighten the locking collar.
c. Reinsert the pin into one of the adjustment holes.
d. Tighten the locking pin screw to secure the pole.
WARNING: The mount is designed to rotate at the swivel ball joint on the mounting flange. Do not rotate the mount at the joints where the pole screws into the mount.
3. Secure the pipe in place by tightening the setscrews. Using the 3/32-inch Allen wrench (supplied), tighten the 10-32 setscrew on the mounting head and the two 10-32 setscrews on the mounting flange.
4. Using the 3/32-inch Allen wrench (supplied), loosen the 10-32 setscrew on the mounting flange ball joint. Slightly loosen the retaining ring on the mounting flange. Do not completely unscrew the retaining ring. Rotate the lower section of the mount at the ball joint until the mounting head is facing the desired direction. Tighten the retaining ring and the 10-32 setscrew to lock the mount into the desired position.
Figure 2. Attaching the Mount to I-beam Ceiling
CONCRETE CEILING
CONCRETE WEDGE
ANCHOR
NUT/LOCK WASHER
Figure 3. Attaching the Mount to Concrete Ceiling
Loading...
+ 2 hidden pages