= Vertical bar in the right margin indicates change or addition.
SWM-PA Series
Pole Adapter for the
®
Spectra
Compact
Wall Mount
Installation/Operation Manual
1.0 WARNINGS
2.0 DESCRIPTION
C294M (11/98)
1. Installation and servicing should only be done by qualified service personnel
and conform to all local codes.
2. Installation shall be done in accordance with all local and national electrical
and mechanical codes utilizing only approved materials.
Please thoroughly familiarize yourself with the information in this
manual prior to installation and operation.
The SWM-P A Series P ole Adapter is designed to adapt P elco’s SWM Series Spectra® Compact Wall Mount to a pole. It can be used for either indoor or outdoor
applications. The adapter is supplied with two stainless steel straps and two stainless steel screws. The adapter is attached to a pole with the two straps, and a
mounting cleat (supplied with the wall mount) is installed on the adapter with the
two stainless steel screws. Once the mounting cleat is firmly in position on the
adapter, the SWM wall mount is then attached and held in place by a set screw.
The adapter and mounting cleat both have a feedthrough opening for electrical
cables, not a conduit fitting.
The adapter is constructed of aluminum and has either a light gray or black polyester powder coat finish.
2.1 MODELS
SWM-PA-GY Pole adapter for use with the SWM Series Spectra® Compact
Wall Mount. Gray finish.
SWM-PA-BK Same as SWM-GY, except black finish.
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
3.0 INSTALLATION
3.1 SWM-PA SERIES
POLE ADAPTER
To attach the SWM-P A Series pole adapter, perf orm the following steps (see Figure
1 and Table A):
1. Determine the location on the pole where the adapter is to be installed.
2. Position the adapter on the pole so the embossed orientation arrow points
upward. Feed the electrical cables through the cable hole, and attach the
adapter to the pole with two stainless steel straps (supplied).
3. After attaching the pole adapter to a pole, apply Duct Seal to the hole and
around the electrical cable. This will pre v ent moisture from entering the mount
and causing condensation which could damage the equipment. Duct Seal can
be purchased through local electrical supply houses.
4
5
2
1
6
3
Figure 1. SWM-PA Pole Adapter Locator Drawing
Table A. SWM-PA Pole Adapter Key List
Item Qty Description
11Pole adapter, gray or black
21Mounting cleat (not supplied)
32Stainless steel strap
42Screw, 1/4-20, socket head
51Spectra® Compact Wall Mount (not supplied)
61Set screw, 10-24 (not supplied)
2 Pelco Manual C294M (11/98)