1. Installation and servicing should be done only by qualified service personnel and conform to all local
codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and must not be installed where exposed to rain and moisture.
3. Use only installation methods and materials capable of supporting four times the maximum
specified load.
Regulatory Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However there is no guarantee that the interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve RadioTV Interference Problems.” This booklet is available from the U.S. Government Printing Office, Washington
D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment
can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
C2462M-D (3/08)5
Page 6
Description
The ICS090 Series Camclosure® integrated camera system integrates a camera and lens package in a
small, discreet dome. The system is easy to install and can be mounted or recessed to the surface of a
ceiling or wall.
Prior to the installation of your new system, thoroughly familiarize yourself with the information in this
manual.
PARTS LIST
The following materials are supplied with the 090 Series Camclosure integrated camera system:
Qty Description
1 Assembled ICS090 Series Camclosure (back box, smoked dome bubble, and camera module)
1Clear dome bubble
1Plastic liner
1Adapter plate
28-32 x 1.00-inch Phillips pan head screws
28-32 x 0.750-inch self-tapping screws
28-32 x 2.50-inch self-tapping screws
210-32 x 1.50-inch self-tapping screws
6C2462M-D (3/08)
Page 7
Remove the Dome Bubble
Turn the dome bubble counterclockwise and lift (refer to Figure 1). Place the bubble on a nonabrasive
surface.
If the unit is supplied with a dome liner, remove the liner before installing the unit. To remove the liner,
gently lift it from the unit. Place the liner to the side; it will be reinstalled along with the bubble after the
installation has been completed following installation..
Figure 1. How to Remove the Dome Bubble
C2462M-D (3/08)7
Page 8
Install the Back Box
The installation methods for the ICS090 Series include the following options:
• Mount to the surface of a ceiling or wall
• Install in a suspended ceiling
• Install in a fixed ceiling or wall
• Mount to the surface of a 4S standard electrical box
• Install in a 4S deep electrical box
Select the best method for your installation and refer to the following pages for instructions.
INSTALLATION TO SURFACE OF A CEILING/WALL
Refer to Figure 2 for the following steps. Refer to Figure 3 if installing the unit to a concrete ceiling/wall.
1. Pull video and power wires through the ceiling/wall.
2. Connect the video cable/wires.
BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.
Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -.
3. Connect the power wires.
Tab le A . Power Input: Surface of Ceiling/Wall Installation
VoltageRed WireBlack Wire
12 VDC+Ground
24 VAC~~
AC operation only: If you are wiring more than one ICS090 Camclosure to the same transformer,
connect one side of the transformer to the red wire on all units, and then connect the other side of the
transformer to the black wire on all units. Failure to connect all of the units in the same way will cause
the cameras to be out of phase with each other, which might produce a vertical roll when switching
between cameras.
8C2462M-D (3/08)
Page 9
4. Use the 6-32 toggle bolts (not supplied) to attach the surface mount ring and back box to the
mounting surface, refer to Figure 2.
NOTE: For a concrete ceiling/wall installation, use 8-32 mounting hardware (not supplied), refer to Figure 3.
Figure 2. Ceiling/Wall Installation
Figure 3. Concrete Ceiling/Wall Installation
C2462M-D (3/08)9
Page 10
IN-CEILING INSTALLATION: SUSPENDED CEILING
Refer to Figure 4 and complete the following steps.
1. Remove the ceiling tile from the ceiling.
2. Cut a 4-inch diameter hole in the ceiling tile.
3. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following
steps:
a.Place your fingers on the circular marks located on the sides of the surface mount ring.
b.Pinch the sides.
c.Lift and remove the surface mount ring from the back box.
NOTE: Do not discard the surface mount ring because it is required to complete the installation.
4. Turn the surface mount ring upside down and place it on the inside of the ceiling tile.
5. Attach the back box to the ceiling tile and surface mount ring with two 10-32 x 1.50-inch selftapping screws (supplied).
SURFACE MOUNT RING
CEILING
TILE
BACK BOX
10-32 x 1.50
SELF-TAPPING
SCREWS
(SUPPLIED)
Figure 4. Ceiling Tile Installation
6. Replace the ceiling tile.
7. Remove an adjacent ceiling tile and connect the video cable/wires.
BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.
Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -.
8. Connect the power wires.
Table B. Power Input: Suspended Ceiling Installation
VoltageRed WireBlack Wire
12 VDC+Ground
24 VAC~~
10C2462M-D (3/08)
Page 11
STANDOFF
BACK BOX
SURFACE
MOUNT RING
Figure 5. How to Remove Surface Mount Ring from Back Box
AC operation only: If you are wiring more than one ICS090 Camclosure to the same transformer,
connect one side of the transformer to the red wire on all units, and then connect the other side of the
transformer to the black wire on all units. Failure to connect all of the units in the same way will cause
the cameras to be out of phase with each other, which might produce a vertical roll when switching
between cameras.
C2462M-D (3/08)11
Page 12
IN-CEILING INSTALLATION: FIXED CEILING/WALL
Refer to Figure 6 and complete the following steps.
1. Cut a 4-inch diameter hole in the ceiling/wall.
2. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following
steps:
a.Place your fingers on the circular marks located on the sides of the surface mount ring.
b.Pinch the sides.
c.Lift and remove the surface mount ring from the back box.
3. Connect the video cable/wires.
BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.
Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -.
4. Connect the power wires.
Tab le C . Power Input: Fixed Ceiling/Wall Installation
VoltageRed WireBlack Wire
12 VDC+Ground
24 VAC~~
AC Operation Only: If you are wiring more than one ICS090 Camclosure to the same transformer,
connect one side of the transformer to the red wire on all units, and then connect the other side of the
transformer to the black wire on all units. Failure to connect all of the units in the same way will cause
the cameras to be out of phase with each other, which might produce a vertical roll when switching
between cameras.
5. Use the 3-16 toggle bolts (not supplied) to attach the back box to the mounting surface.
Figure 6. In-Ceiling Installation to a Fixed Ceiling/Wall
12C2462M-D (3/08)
Page 13
INSTALLATION TO THE SURFACE OF A 4S STANDARD
ELECTRICAL BOX
Refer to Figure 7 and complete the following steps.
1. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied).
2. Connect the video cable/wires.
BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.
Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -.
3. Connect the power wires.
Tab le D . Power Input: 4S Standard Electrical Box Installation
VoltageRed WireBlack Wire
12 VDC+Ground
24 VAC~~
AC Operation Only: If you are wiring more than one ICS090 Camclosure to the same transformer,
connect one side of the transformer to the red wire on all units, and then connect the other side of the
transformer to the black wire on all units. Failure to connect all of the units in the same way will cause
the cameras to be out of phase with each other, which might produce a vertical roll when switching
between cameras.
4. Attach the surface trim ring and back box to the adapter plate with the two 8-32 x 2.50-inch screws
(supplied).
4S STANDARD
ELECTRICAL BOX
CEILING/
WALL
8-32 X 1.00
(SUPPLIED)
8-32 X 2.50
(SUPPLIED)
OPTIONAL
ADAPTER RING
BACK BOX AND
SURFACE MOUNT
RING
Figure 7. 4S Standard Electrical Box Installation
C2462M-D (3/08)13
Page 14
INSTALLATION IN A 4S DEEP ELECTRICAL BOX
Refer to Figure 8 and complete the following steps.
1. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following
steps:
a.Place your fingers on the circular marks located on the sides of the surface mount ring.
b.Pinch the sides.
c.Lift and remove the surface mount ring from the back box.
2. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied).
3. Connect the video cable/wires.
BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.
Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -.
4. Connect the power wires.
Table E. Power Input: 4S Deep Electrical Box Installation
VoltageRed WireBlack Wire
12 VDC+Ground
24 VAC~~
AC operation only: If you are wiring more than one ICS090 Camclosure to the same transformer,
connect one side of the transformer to the red wire on all units, and then connect the other side of the
transformer to the black wire on all units. Failure to connect all of the units in the same way will cause
the cameras to be out of phase with each other, which might produce a vertical roll when switching
between cameras.
5. Attach the back box to the adapter plate with the two 8-32 x 0.750-inch screws (supplied).
4S DEEP ELECTRICAL BOX
CEILING/
WALL
8-32 x 1.00
(SUPPLIED)
8-32 X .750
(SUPPLIED)
ADAPTER
RING
BACK
BOX
Figure 8. 4S Deep Electrical Box Installation
14C2462M-D (3/08)
Page 15
Camera Positioning
Manually rotate and tilt the camera module to position the camera. Do not over-rotate the
module.
WARNING: Excessively turning the module in one direction could result in damage to the wiring.
ì Tilt 140° î Pan 360° ï Rotation 360°
Figure 9. Positioning the Camera
C2462M-D (3/08)15
Page 16
Camera Adjustments
SWITCH SETTINGS
SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITHOUT
AUTO IRIS
Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation
(factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions
where there are no bright spots that darken other picture details. Manual backlight compensation is used
in fixed lighting conditions, to optimize the picture detail when there are bright spots.
•ALC/ELC switch: Always ELC
•Y/DC switch: Not used
•Auto backlight compensation: BLC switch OFF ABL switch ON
•Manual backlight compensation: BLC switch ON ABL switch OFF
FACTORY SETTINGS
ALCYBL
ON
OFF
ELC
= SWITCH POSITION
NOT USED
DC
OFF
ABL
OFF
16C2462M-D (3/08)
Page 17
VERTICAL PHASE ADJUSTMENT (24 VAC OPERATION ONLY)
When using more than one camera power supply, a brief vertical roll may occur on the monitor when a
camera view is switched. To eliminate vertical roll, reverse the 24 VAC connections on one camera. If both
cameras are connected to the same transformer, this should solve the problem. If reversing the
connections does not solve the problem, adjust the phase control by synchronizing, or line-locking, the
cameras to one another.
ADJUSTING THE PHASE CONTROL
It may be necessary to have two people in communication when synchronizing the cameras: one person at
the camera and another person at the monitor to observe the vertical roll and the effect of any adjustments
made at the camera.
To synchronize the cameras:
1. Choose a reference camera to which all other cameras will be phased.
2. Select a camera and synchronize it to the reference camera by turning the phase adjustment control
(refer to Figure 10) clockwise or counterclockwise.
3. Each time an adjustment is made, switch back and forth between the camera you are adjusting and
the reference camera. Repeat this process as many times as necessary, until the roll between the
cameras is no longer noticeable.
4. Adjust the phase of all other cameras by repeating steps 2 and 3. Always adjust to the reference
camera selected in step 1.
NOTE: The preferred method for camera phase adjustment is to use a dual trace oscilloscope to align
the vertical sync pulses of the reference camera to the selected camera(s).
Figure 10. Vertical Phase Adjustment
C2462M-D (3/08)17
Page 18
Reinstall the Dome Bubble
DOME LINER INSTALLATION
If the unit is supplied with a dome liner, reinstall the liner before installing the dome bubble. To install the
liner, refer to Figure 11 complete the following steps:
1. Align the studs located on the camera module with the clips on the liner.
2. Lightly pinch the sides of the liner, opposite from the clips, and place the clips over the studs.
3. Once the liner is secure, position the viewing window of the liner over the lens of the camera.
4. Install the bubble.
Figure 11. Installing the Dome Liner
18C2462M-D (3/08)
Page 19
DOME BUBBLE INSTALLATION
To install the dome bubble refer to Figure 12 and complete the following steps:
1. Select the bubble (clear or smoked).
2. Align the standoffs of the bubble with the slots of the back box.
3. Turn the bubble clockwise, until it locks in place.
Figure 12. Installing the Dome Bubble
C2462M-D (3/08)19
Page 20
Service Connector
An optional 4-foot service/monitor cable, part number ICS090-SC, is available for on-site setup and
adjustments. To use the cable simply plug one end of the cable directly into the service connector of the
ICS090, and then connect the other end to any standard BNC (VIDEO IN) connector on a monitor.
To assemble a longer service cable for the ICS090 Series Camclosure, purchase the following parts at a
local electronics supply store:
Qty Description
12.5 mm monaural headphone plug
1CPM 88 miniature coaxial connector
1RG174/U coaxial cable
To assemble the cable:
1. Attach the CPM 88 miniature coaxial connector to one end of the cable. Follow the directions
supplied with the miniature coaxial connector.
2. Refer to Figure 13 and complete the following steps to attach the 2.5 mm monaural plug to the other
end of the coaxial cable:
a.Remove the support sleeve from the plug, and then slip the support sleeve over the end of the
cable.
b.Prepare the cable.
c.Solder the center connector of the cable to the center pin of the plug.
d.Thread the braid of the cable through the hole in the crimp pin, and then solder the braid to
the top of the crimp pin.
e.Crimp the end of the crimp pin around the cable.
f.Reassemble the support sleeve and the plug.
CENTER CONDUCTOR
COAXIAL
CABLE
Figure 13. Connecting the Monaural Headphone Plug to the Coaxial Cable
20C2462M-D (3/08)
BRAID (SHIELD)
2.5 mm MONAURAL
HEADPHONE PLUG
Page 21
Specifications
BACKBOX
Electrical
Input Voltage12 VDC or 24 VAC (±10%), autosensing
Power Consumption3 W or less
Video ConnectorBNC
General
Pan/Tilt Adjustment
Pan360°
Tilt 140° (20° to 160° range)
Rotation360°
Construction
Back Box and
Surface Mount RingABS plastic
BubblePolycarbonate
FinishWhite
EnvironmentIndoor
Operating Temperature32° to 120°F (0° to 49°C)
Weight
Unit 0.52 lb (0.24 kg)
Shipping2.0 lb (0.91 kg)
(Design and product specifications subject to change without notice.)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES
C2462M-D (3/08)21
Page 22
The materials used in the manufacture of this document and its components are compliant to the requirements
of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive
2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE).
Contact your local dealer for procedures for recycling this equipment.
22C2462M-D (3/08)
Page 23
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, an y merchandise proved defective in material or workmanship for a period of one year after the date of
shipment.
Exceptions to this warranty are as noted below:
• Five years on fiber optic products and TW3000 Series unshielded twisted pair (UTP) transmission products.
• Three years on Spectra® IV products.
• Three years on Genex® Series products (multiplexers, server, and keyboard).
• Three years on DX Series digital video recorders, DVR5100 Series digital video recorders, DigitalSENTRY® Series hardware products, DVX Series
digital video recorders, NVR300 Series netwo rk video recorders, and Endura® Series distributed network-based video products.
• Three years on Camclosure® and Pelco-branded fixed camera models, except the CC3701 H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2,
and MC3651H-2X camera models, which ha ve a five-year warranty.
• Three years on PMCL200/300/400 Series LCD monit ors.
• Two years on standard motorized or fixed focal length lenses.
• Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.
• Two years on Spectra III™, Spectra Mini, Esprit®, ExSite®, and PS20 scanners, including when used in continuous motion applications.
• Two years on Esprit and WW5700 Series window wiper (excluding wiper blades).
• Two years (except lamp and color wheel) on Digital Light Processing (DLP®) displays. The lamp and color wheel will be covered for a period of
90 days. The air filter is not covered un der warranty.
• Two years on Intelli-M® eIDC controllers.
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners, or pre set lenses used in continuous motion applications (preset scan, tour, and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent
freight prepaid to a Pelco designated locatio n. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are no t covered under
this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the
Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental, or
consequential damages (including loss of use, loss of profit, and claims of third parties) however caused, whether by the negligence of Pelco or
otherwise.
The above warranty provides the Dealer with spe cific legal rights. The Dealer may also have additional right s, which are subject to variation from state
to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and
provide the following information:
1. M odel and serial number
2. D ate of shipment, P.O. number, sales order number, or Pelco invoice number
3. D etails of the defect or problem
If there is a dispute regarding the warranty of a product that does not fall un der the warranty conditions stated above, please include a written
explanation with the product wh en returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA n umber if
returned for credit, and RA number if returned for repair) and designated return location.
All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid.
1-8-08
REVISION HISTORY
Manual # Date Comments
C2462M 11/02Original version.
C2462M-A1/03Added Regulatory Notices for FCC Class B.
C2462M-B10/05Revised switch-setting descriptions for varifocal lens. Added WEEE statement.
C2462M-C1/06Updated factory switch settings for varifocal lens per ECO 13164. Updated wiring
C2462M-D3/08Revised for standard resolution color cameras with fixed focal lenses.