Type: ________________________
Tulip Symmetric
Direct T5
SPECIFICATIONS
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
Suspended TLMS
Project: ______________________
LAMPING OPTIONS
TLMS
4”
3 5⁄8”
SPECIFICATIONS
Construction
Extruded aluminum housing forms a 3 5⁄8” x 4”
curved channel. Die-cast aluminum end caps
mechanically attached with no exposed fasteners.
Reflectors
High reflectance white painted reflector system.
Shielding
Arc-shaped, parabolic low iridescent semi-specular
or white painted aluminum louver.
Finish
Satin anodized or white low gloss paint. With satin
anodized option, housing is satin anodized and end
caps are painted to match. Custom colors available,
consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wire s. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’, 8’ and 12’ lengths in a single section for exact
suspension spacing of 4’, 8’, and 12’. For total
luminaire length, add 3⁄8” for each end cap or 1”
for each sculptured end cap (SCEP) when F3 stem
mount or option ELS2 is specified. Using internal
joiners, 4’, 8’ and 12’ sections can be joined to form
longer rows.
CATALOG NUMBER
Examples: TLMS 1 28T5 SSB 40FT R8 120 GEB10 SCT LP835 F1/18 C100 — TLMS 1 28T5 WPB 40FT R8 277 GEB10 1SE EC SCT LP835 F2/24 C041
__________ __________ __________ __________ _________ __________ __________ __________ __________ __________
Luminaire
TLMS
______________ ________________ ______________ ______________ ______________ _________________________________
Switching
SCT Single circuit
# of
Lamps in
Cross
Section
1
Lamp Color
L/LP No lamp
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
LP830P
LP835P
LP841P
Reference Lamp Chart on
website or consult factory
for other options.
Lamp Type
28T5 28W T5
3000K 80+
CRI Premier
3500K 80+
CRI Premier
4100K 80+
CRI Premier
Shielding
SSB Semi
White
WPB
specular
bae
painted
bae
Luminaire
Row
Length
X FT
(4’ increments)
Mounting Type /
F1/ T-bar ceiling (universal
mounting bracket)
T-bar ceiling (UMB with
F1A/
integrated J-box)
Hard ceiling (horizontal
F2/
J-box)
4
/ Rigid stem
F3
Maximum
Section
Length
R4 4’ section(s)
R8 8’ section(s)
R12 12’ section(s)
Overall Suspension
12 12”
15 15”
18 18”
21 21”
24 24”
XX XX”
Overall suspension is measured
from ceiling to bottom of
luminaire.
Voltage
120
277
347
Ballast Type
GEB10 <10% THD Electronic
DMHL3D1 Lutron Hi-Lume dim
Reference Ballast Wizard on website
or consult factory for other options.
Finish
C041 White white (low
gloss)
Satin anodized
C100
finish
Custom finish
C099
# of Emergency
Modules
(Blank) None
1SE 1 section
2SE 2 sections
XSE X sections
Emergency Type
(Blank) None
EC Emergency circuit
EL1 Emergency battery pack
EN1 Emergency battery pack
Options
ACG Adjustable cable grippers
BLK Black cord, cord manager and canopy (not available with F3)
CP Chicago plenum (available with F1A only)
DL Damp location label
ELH Emergency through wiring w/separate feed
ELS Emergency through wiring w/single feed, shared neutral
ELS23 Emergency through wiring w/single feed, separate neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
MCS Matching feed canopy at support
NEPP5D nLight enabled control module per row/zone
NYC New York City code
OJB Oset junction box
SLP Sloped ceiling (for 10-45°, must be specified with F2, ACG and
OJB options)
Integrated sensor; choose options and obtain code on page 2
XXXX
2
w/night light circuit
Notes:
1 Not available in 347V
2 Emergency type is installed in last 4’ of luminaire
sections. Separate feed required unless ELS or ELS2 is specified
3 1” sculptured end cap (SCEP) used
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
TLMS Tulip Symmetric
Direct T5
1

STANDARD SECTIONS
4’-0”
3
⁄8” standard flat end plates
4’-0
3
⁄4” O.A.
8’-0”
8’-0
3
⁄4” O.A.
12’-0”
12’-0
3
⁄4” O.A.
Key:
•
Support or feed location
PLAN VIEW
Type: ________________________
Tulip Symmetric
Project: ______________________
Direct T5
Suspended TLMS
INTEGRATED NLIGHT MICRO SENSOR
Determine the appropriate sensor type, network type and sensor power source for your application. Enter the code in the Options section of the Catalog Number.
EXAMPLE: PDT1
Sensor Type (choose one)
ADC
nLight model
nES ADCX
PDT
nLight model
nES PDT7 ADCX
For more information about the Integrated nLight Micro Sensor, its capabilities and options, download the PDF guide at: PeerlessLighting.com/nLight-Sensor-Guide
*nLight-Enabled (network-ready) options include one RJ-45 connector on the luminaire and 10’ of Cat-5e cable and a splitter to control the entire luminaire row (depending on
wattage/voltage limitations). The Cat-5e cable drop is located in the same section as the sensor. For multiple zones, please contact techsupport@peerlesslighting.com.
Daylight Dimming
Specify 0-10V dimming ballast
No occupancy sensing
Daylight Dimming and/or Occupancy Detection
Specify 0-10v dimming ballast for daylight dimming
Specify fixed-output ballast for occupancy detection only
(daylight dimming disabled)
1* nLight-Enabled (Network-Ready) with Luminaire-Integrated Power Pack
10’ Cat-5e cable and splitter provided
2 Standalone Operation (No Networking) with Luminaire Integrated Power Pack
No Cat-5e cable provided
3* nLight-Enabled (Network-Ready) with Remote nLight Power Pack or nPanel
10’ Cat-5e cable and splitter provided
Order required remote nLight Power Pack or nPanel
separately through nLight (Acuity Brands Controls)
WEIGHTS & SUPPORT SPACING
Suspension spacing equals section length. Default location shown. Consult factory for stem mounting suspension spacing and alternate locations.
Network Type & Sensor Power Source (choose one)
12 LBS
24 LBS
36 LBS
CONFIGURATIONS
Mitered “L”, “X” and “T” connectors available for suspended configurations.
Reference Pattern Connector Guide for additional details.
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
TLMS Tulip Symmetric
Direct T5
2