Catalog Number
___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________
Luminaire Ceiling Type # of Lamps in
Rectangular
®
IRDM8QS
IRDM8QST
with OPD
(Blank) Suspended S Surface
mounted
Specifications
CONSTRUCTION — Nominal 6” x 4” with extruded aluminum spine and nominal four 4’ one-piece aluminum bae assemblies. Steel and die-cast aluminum sculptured end cap.
SHIELDING — Straight blade baes with perforated side reflector/shield or opal acrylic diuser.
REFLECTORS — White painted center reflector (nominal 90% reflectance). Perforated side reflector/shield.
FINISH — White polyester powder paint standard.
LUMINAIRE LENGTH — 4’, 8’, and 12’ lengths in a single section for exact suspension spacing of 4’, 8’ and 12’. For total luminaire length, add 1 1⁄4” for each end cap. Using internal joiners 4’, 8’, and 12’ sections can be joined to form longer rows.
DISTRIBUTION — 100% downlight. See non-QuickShip spec sheet for photometrics.
Sample Catalog Number: IRDM8QS 1 54T5HO OPD 28FT R12 277 GEB10 SCT LP835 F1/24 C041 ACG
Cross Section
1 2
Lamp Type Shielding Luminaire Row
28T5 28W T5 54T5HO 54W T5HO 32 32W T8
SBP Side
perforated shield
OPD4 Bae w/ opal
overlay
Length
X FT
(4’ increments)
Maximum Section Length
R4 4’ section(s) R8 8’ section(s) R12 12’ section(s)
Dimensions / Lamping
3 13⁄16 3 13⁄16
6 3⁄8 6 3⁄8
(1, 2) T5, T5HO or T8 (1) T5, T5HO or T8 Shown with SBP Shown with OPD
Voltage Ballast Type # of Emergency
120 277
GEB10 <10% THD Electronic
(all lamp types)
GEB10/347V 347V Generic non-dim. Only
available with 10-day QuickShip
OS5C Osram 0-10V dim or line
voltage control (32 T8)
ADEZ Advance Mark 10 dim
(54T5HO)
OSDIM Osram 0-10V dim (54T5HO)
ADZT Advance Mark 7 0-10V dim (54T5HO). Only available with 10-day QuickShip
Modules
(Blank) None 1SE 1 section 2SE 2 sections XSE X sections
IceTray
DIRECT
___________ ___________ ___________ ___________ ___________ ___________ ___________
Emergency Type1Switching Lamp Color Mounting Type     / Overall Suspension
(Blank) None EC Emergency
circuit
EL2 Emergency
battery pack
EN2 Emergency
battery pack w/night light circuit
Notes:  1 Emergency type is installed in last 4’ of luminaire sections. Separate feed required unless ELS or ELS2 is specified 2 Not available with dimming 
3 Maximum of 240” 4 Not available with 2 lamp cross section
SCT Single circuit DCT2 Dual circuit
L/LP* No lamp LP830 3000K 80+ CRI LP835 3500K 80+ CRI LP841 4100K 80+ CRI
*Wired for full wattage lamps only, do not install low wattage lamps
(Blank) Surface mounted F1/ T-bar ceiling
(universal mounting bracket)
F1A/ T-bar ceiling (UMB
with integrated J-box)
F2/ Hard ceiling
(horizontal J-box)
(Blank) Surface mounted 12 12” 15 15” 18 18” 21 21” 24 24” XX XX”
Overall suspension is measured from ceiling to bottom of luminaire
3
Finish Options
C041 White white
(low gloss)
ACG Adjustable cable grippers CP Chicago plenum (available with F1A only) ELH Emergency through wiring w/separate feed ELS2 Emergency through wiring w/single feed, shared neutral ELS22 Emergency through wiring w/single feed, separate neutrals GLR Fusing (fast blow) GMF Fusing (slow blow) MCS Matching feed canopy at support OJB Oset junction box
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
Specifications subject to change without notice. 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
© 2013 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “IceTray” are registered trademarks of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending.