Type: ________________________
IceTray Angular Direct
Project: ______________________
Direct T5/T5HO
With SBP With OPD
SPECIFICATIONS
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
Suspended and Surface Mount IADM8
LAMPING OPTIONS
IADM8 - 1 SBP IADM8 S - 1 SBP IADM8 - 2 SBP IADM8 S - 2 SBP IADM8 - 1 OPD IADM8 S - 1 OPD
3 13⁄16”
7 1⁄8”
SPECIFICATIONS
7 1⁄8” 7 1⁄8” 7 1⁄8”
Construction
Nominal 7” x 4” with extruded aluminum spine
and nominal four 4’ one-piece aluminum bae
assemblies. Steel and die-cast aluminum sculptured
end cap.
3
⁄8”
3 13⁄16”
7 1⁄8”
3 13⁄16”
Shielding
Straight blade baes with perforated side
reflector/shield or opal acrylic diuser.
Finish
3
3 13⁄16”
⁄8”
7 1⁄8”
3 13⁄16”
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Satin anodized or white polyester powder paint.
Reflectors
White painted center reflector (nominal 90%
reflectance). Perforated side reflector/shield.
Satin anodized finish consists of satin anodized
housing, clear-coated aluminum baes and end
caps painted C110 to match. Note that clear coated
aluminum baes retain the slight imperfections
and characteristics of the raw aluminum source
material. Custom colors available, consult factory.
Luminaire Length
4’, 8’, and 12’ lengths in a single section for exact
suspension spacing of 4’, 8’ and 12’. For total
luminaire length, add 1 3⁄8” for each end cap. Using
internal joiners 4’, 8’, and 12’ sections can be joined
to form longer rows.
CATALOG NUMBER
Examples: IADM8 2 28T5 SBP 20FT R8 120 GEB10 SCT LP835 F1/24 C100 — IADM8 S 1 28TS OPD 24FT R12 277 GEB10 1SE EN SCT LP841 C041
3
⁄8”
3 13⁄16”
__________ __________ __________ __________ __________ _________ __________ __________ __________ __________
Luminaire
IADM8
______________ ________________ ________________ ______________ ______________ ______________ _________________________________
Emergency Type
(Blank) None
EC Emergency
EL2 Emergency
EN2 Emergency
Notes:
1 Not available with 2-lamp cross section
2 Not available in 347V
3 Not available with 28T5 lamps
Ceiling Type
(Blank) Suspended
S Surface
circuit
battery pack
battery pack
w/night light
circuit
mounted
4
Switching
SCT Single circuit
DCT Dual circuit
# of
Lamps in
Cross
Section
1
2
Lamp Type
28T5 28W T5
54T5HO 54W T5HO
Lamp Color
L/LP No lamp
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Available with T5 only:
LP830P 3000K 80+
CRI Premier
LP835P 3500K 80+
CRI Premier
LP841P 4100K 80+
CRI Premier
Reference Lamp Chart on
website or consult factory
for other options.
4 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified
Shielding
OPD1 Straight blade bae
SBP Straight blade bae
Mounting Type /
F1/ T-bar ceiling (universal
F1A/ T-bar ceiling (UMB with
F2/ Hard ceiling (horizontal
F3/ Rigid stem
with opal diuser
with side perforated
shield
mounting bracket)
integrated J-box)
J-box)
Luminaire
Row
Length
X FT
(4’ increments)
Overall Suspension
12 12”
15 15”
18 18”
21 21”
24 24”
XX XX”
Overall suspension is
measured from ceiling to
bottom of luminaire.
Maximum
Section
Length
R4 4’ section(s)
R8 8’ section(s)
R12 12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10 <10% THD Electronic
ADEZ
DMHL3D2 Lutron Hi-Lume dim
OSDIM
Reference Ballast Wizard on website
or consult factory for other options.
Finish
C041 White white (low
gloss)
C100 Satin anodized
finish
C099 Custom finish
# of Emergency
Modules
2,3
Advance Mark 10 dim
2,3
Osram 0-10V dim
(Blank) None
1SE 1 section
2SE 2 sections
XSE X sections
Options
ACG Adjustable cable grippers
BLK Black cord, cord manager and canopy
(not available with F3)
CP Chicago plenum (available with F1A only)
DL Damp location label
ELH Emergency through wiring w/separate
feed
ELS Emergency through wiring w/single feed,
shared neutral
ELS2 Emergency through wiring w/single feed,
separate neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
MCS Matching feed canopy at support
OJB Oset junction box
NEPP5D nLight enabled control module per
row/zone
NYC New York City code
SLP Sloped ceiling (for 10-45°, must be
specified with F2, ACG and OJB options)
XXXX Integrated sensor; choose options and
obtain code on page 2
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “IceTray” are registered trademarks of Acuity Brands Lighting.
IADM8 IceTray Angular
Direct T5/T5HO
1

Type: ________________________
IceTray Angular Direct
Project: ______________________
Direct T5/T5HO
Suspended and Surface Mount IADM8
INTEGRATED NLIGHT MICRO SENSOR
Determine the appropriate sensor type, network type and sensor power source for your application. Enter the code in the Options section of the Catalog Number.
EXAMPLE: PDT1
Sensor Type (choose one)
ADC
nLight model
nES ADCX
PDT
nLight model
nES PDT7 ADCX
For more information about the Integrated nLight Micro Sensor, its capabilities and options, download the PDF guide at: PeerlessLighting.com/nLight-Sensor-Guide
*nLight-Enabled (network-ready) options include one RJ-45 connector on the luminaire and 10’ of Cat-5e cable and a splitter to control the entire luminaire row (depending on
wattage/voltage limitations). The Cat-5e cable drop is located in the same section as the sensor. For multiple zones, please contact techsupport@peerlesslighting.com.
Daylight Dimming
Specify 0-10V dimming ballast
No occupancy sensing
Daylight Dimming and/or Occupancy Detection
Specify 0-10v dimming ballast for daylight dimming
Specify fixed-output ballast for occupancy detection only
(daylight dimming disabled)
1* nLight-Enabled (Network-Ready) with Luminaire-Integrated Power Pack
10’ Cat-5e cable and splitter provided
2 Standalone Operation (No Networking) with Luminaire Integrated Power Pack
No Cat-5e cable provided
3* nLight-Enabled (Network-Ready) with Remote nLight Power Pack or nPanel
10’ Cat-5e cable and splitter provided
Order required remote nLight Power Pack or nPanel
separately through nLight (Acuity Brands Controls)
WEIGHTS & SUPPORT SPACING
Suspension spacing equals section length. Default location shown. Consult factory for stem mounting suspension spacing and alternate locations.
STANDARD SECTIONS
1
⁄8”
7
⁄8” O.A.
3
⁄8” end cap
12–13.5 LBS
24–25.5 LBS
4’-0 1⁄4” 1
5
⁄8” O.A.
4’-1
8’-0
8’-2
Network Type & Sensor Power Source (choose one)
Key:
Support or feed location
•
36–37.5 LBS
CONFIGURATIONS
PHOTOMETRICS
12’-0”
3
⁄4” O.A.
12’-2
Tenon “L”, “T”, “X” and straight connectors available for suspended configurations.
Reference Pattern Connector Guide for additional details.
Actual performance may dier as a result of end-user environment and application.
1-LAMP T5HO
75.4% eciency
3770 delivered lumens
1.1% up / 98.9% down
1-LAMP T5HO WITH OPD
68.3% eciency
3417 delivered lumens
3.9% up / 96.1% down
2-LAMP T5HO
71.9% eciency
7192 delivered lumens
1.1% up / 98.9% down
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “IceTray” are registered trademarks of Acuity Brands Lighting.
IADM8 IceTray Angular
Direct T5/T5HO
2