Type: ________________________
Contrail Linear
Indirect-Direct T5/T5HO
SPECIFICATIONS
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
Suspended CLM9
Project: ______________________
LAMPING OPTIONS DESIGN GUIDELINES
CLM9 - 2
6”
Because the shielding (diuser) is fully luminous,
color variations in the lamp may create subtle
fluctuations in the color of the shield.
3”
If dual switching is required for energy savings,
dimming or the alternating lamp circuit switching
option (ALC) is recommended in place of the dual
circuit switching option (DCT). DCT will switch
each side of a luminaire row separately which will
aect the uniform luminous aesthetic of the lens.
ALC will switch every other 4’ section of a luminaire
row separately.
SPECIFICATIONS
Construction
Die-formed pre-painted steel housing. Extruded
aluminum fillers. Die-cast aluminum end caps.
Highly specular aluminum end plates.
Shielding
GrateOptic curved, crenulated diuser is extruded
opal acrylic.
Reflectors
Die-formed, highly specular aluminum reflector has
a minimum 98% reflectance.
Finish
Fine-textured, white polyester powder paint is
standard on the fillers and end caps.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’, 8’, and 12’ individual luminaire sections for
nominal suspension spacing of 4’, 8’ and 12’. Add
3 5⁄8” for each end cap to determine total luminaire
length. Using internal joiners, 4’, 8’ and 12’ sections
can be joined to form longer length luminaires.
CATALOG NUMBER
Examples: CLM9 2 28T5 COA 40FT R8 277 GEB10 SCT LP835 F1/18 — CLM9 2 54T5HO COA 32FT R8 277 GEB10 1SE EL SCT LP835 F1/21
__________ __________ __________ __________ _________ __________ __________ __________ __________ __________
Luminaire
CLM9
______________ ________________ ______________ ______________ _________________________________
Switching
SCT Single circuit
ALC Alternate lamping
Notes:
1 Not available in 347V
2 Not available with 28T5 lamps
3 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified
4 Option EL or EN (Battery Pack) is :
a. not permitted with dimming in the same row
# of
Lamps in
Cross
Section
2
5
module circuit
Lamp Type
28T5 28W T5
54T5HO 54W T5HO
Shielding
COA Crenulated
Lamp Color
L/LP No lamp
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Available with T5 only:
LP830P 3000K 80+ CRI Premier
LP835P 3500K 80+ CRI Premier
LP841P 4100K 80+ CRI Premier
Reference Lamp Chart on website or
consult factory for other options.
Luminaire
Row
opal
acrylic
Length
X FT
(4’ increments)
Mounting Type /
F1/ T-bar ceiling (universal
mounting bracket)
F1A/ T-bar ceiling (UMB with
integrated J-box)
F2/ Hard ceiling (horizontal J-box)
b. must be in the same section as the lamp being operated
c. not permitted in a 4’ section
d. limited to one battery pack per section
5 SCT with or without dimming, or ALC is recommended
over DCT. DCT and ALC are not available with dimming
Maximum
Section
Length
R4 4’ section(s)
R8 8’ section(s)
R12 12’ section(s)
Overall Suspension
12 12”
15 15”
18 18”
21 21”
24 24”
XX XX”
Overall suspension is
measured from ceiling to
bottom of luminaire.
Voltage
120
277
2
347
Ballast Type
GEB10 <10% THD Electronic
1,2
ADEZ
Advance Mark 10 dim
DMHL3D1 Lutron Hi-Lume dim
1,2
OSDIM
Osram 0-10V dim
Reference Ballast Wizard on website
or consult factory for other options.
# of Emergency
Modules
(Blank) None
1SE 1 section
2SE 2 sections
XSE X sections
Options
ACG Adjustable cable grippers
BLK Black cord, cord manager and canopy
DL Damp location label
ELH Emergency through wiring w/separate feed
ELS Emergency through wiring w/single feed, shared neutral
ELS2 Emergency through wiring w/single feed, separate neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
MCS Matching feed canopy at support
NEPP5D nLight enabled control module per row/zone
OJB Oset junction box
SLP Sloped ceiling (for 10-45°, must be specified with F2, ACG and
OJB options)
XXXX Integrated sensor; choose options and obtain code on page 2
Emergency Type
(Blank) None
EC Emergency circuit
1,4
EL
1,4
EN
3
Emergency battery
pack
Emergency battery
pack w/night light
circuit
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Contrail” are registered trademarks of Acuity Brands Lighting.
CLM9 Contrail Linear
Indirect-Direct T5/T5HO
1

Type: ________________________
Contrail Linear
Project: ______________________
Indirect-Direct T5/T5HO
Suspended CLM9
INTEGRATED NLIGHT MICRO SENSOR
Determine the appropriate sensor type, network type and sensor power source for your application. Enter the code in the Options section of the Catalog Number.
EXAMPLE: PDT1
Sensor Type (choose one)
ADC
nLight model
nES ADCX
PDT
nLight model
nES PDT7 ADCX
For more information about the Integrated nLight Micro Sensor, its capabilities and options, download the PDF guide at: PeerlessLighting.com/nLight-Sensor-Guide
*nLight-Enabled (network-ready) options include one RJ-45 connector on the luminaire and 10’ of Cat-5e cable and a splitter to control the entire luminaire row (depending on
wattage/voltage limitations). The Cat-5e cable drop is located in the same section as the sensor. For multiple zones, please contact techsupport@peerlesslighting.com.
Daylight Dimming
Specify 0-10V dimming ballast
No occupancy sensing
Daylight Dimming and/or Occupancy Detection
Specify 0-10v dimming ballast for daylight dimming
Specify fixed-output ballast for occupancy detection only
(daylight dimming disabled)
1* nLight-Enabled (Network-Ready) with Luminaire-Integrated Power Pack
10’ Cat-5e cable and splitter provided
2 Standalone Operation (No Networking) with Luminaire Integrated Power Pack
No Cat-5e cable provided
3* nLight-Enabled (Network-Ready) with Remote nLight Power Pack or nPanel
10’ Cat-5e cable and splitter provided
Order required remote nLight Power Pack or nPanel
separately through nLight (Acuity Brands Controls)
WEIGHTS & SUPPORT SPACING
Suspension spacing equals section length. Default location shown. Consult factory for stem mounting suspension spacing and alternate locations.
STANDARD SECTIONS
5
3
⁄8” end cap
12’-0”
1
12’-7
⁄4” O.A.
12 LBS
26 LBS
37 LBS
PLAN VIEW
4’-7
4’-0”
1
⁄4” O.A.
8’-7
8’-0”
1
⁄4” O.A.
Network Type & Sensor Power Source (choose one)
Key:
Support or feed location
•
CONFIGURATIONS
Mitered tenon corner and tenon connectors available for suspended configurations.
Reference Pattern Connector Guide for additional details.
PHOTOMETRICS
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
Actual performance may dier as a result of end-user environment and application.
2-LAMP T5
81.8% eciency
4746 delivered lumens
90.1% up / 9.9% down
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Contrail” are registered trademarks of Acuity Brands Lighting.
2-LAMP T5HO
81.8% eciency
8182 delivered lumens
90.1% up / 9.9% down
CLM9 Contrail Linear
Indirect-Direct T5/T5HO
2