Type: ________________________
Bruno Holes
Indirect T8
SCEP Option
SPECIFICATIONS
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
Suspended BRM3
Project: ______________________
LAMPING OPTIONS
BRM3 - 1 BRM3 - 2 BRM3 - 3
8 1⁄4”
1 3⁄4”
1
⁄2”
8 1⁄4”
1 3⁄4”
1 3⁄4”
1
⁄2”
1
⁄2”
8 1⁄4”
SPECIFICATIONS
Construction
Nominal 8 1⁄4” x 1 3⁄4” rectangular housing is formed
from cold-rolled steel. Die-cast end caps are
mechanically attached with no exposed fasteners.
Reflectors
Die-formed specular reflector with 95% reflectance.
Shielding
Aluminum, die-formed drop pan with five 2 3⁄4”
cylinder openings of down light feature. Also
available with acrylic opal overlay on top of down
light openings.
Finish
Fine textured white polyester powder paint is
standard. Drop pan always C110 painted
Aluminum Finish. Consult factory for special
finish requirements.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’ 3⁄8”, 8’ and 12’ lengths in a single section for
nominal support spacing at 4’, 8’ and 12’. For total
luminaire length, add 5⁄8” for each flat end cap
and 4” for each sculptured end cap. Using internal
joiners, 4’, 8’ and 12’ sections can be joined to form
longer rows.
CATALOG NUMBER
Examples: BRM3 2 32 SPR 40FT R8 277 GEB10 DCT LP835 F1/18 C210 SCEP — BRM3 3 32 SPR OPD 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21 C110
__________ __________ __________ __________ __________ _________ __________ __________ __________ __________
Luminaire
BRM3
______________ __________ ________________ ______________ ______________ ______________ _________________________________
Emergency Type
(Blank) None
EC Emergency
EL1 Emergency
EN1 Emergency
Notes:
1 Not available in 347V
2 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified
# of
Lamps in
Cross
Section
1
2
3
circuit
battery pack
battery pack
w/night light
circuit
Lamp Type
32 32W T8
2
Switching
SCT Single
DCT Dual
Lamp Color
L/LP No lamp
circuit
L/LPE No lamp. Wired
circuit
LP830 3000K 80+ CRI
LP835 3500K 80+ CRI
LP841 4100K 80+ CRI
Reference Lamp Chart on
website or consult factory
for other options.
Reflector
SPR Specular
reflector
for energy saving
lamps.
Shielding
(Blank) None
OPD Bae w/std
brightness
opal diuser
overlay
Luminaire
Row
Length
X FT
(4’ increments)
Mounting Type /
F1/ T-bar ceiling (universal
mounting bracket)
F1A/ T-bar ceiling (UMB with
integrated J-box)
F2/ Hard ceiling (horizontal
J-box)
F3/ Rigid stem
Maximum
Section
Length
R4 4’ section(s)
R8 8’ section(s)
R12 12’ section(s)
Overall Suspension
12 12”
15 15”
18 18”
21 21”
24 24”
XX XX”
Overall suspension is
measured from ceiling to
bottom of luminaire.
Voltage
120
277
347
Ballast Type
GEB10 <10% THD Electronic
ADEZ1 Advance Mark 10 dim
DMHL3D1 Lutron Hi-Lume dim
OSDIM1 Osram 0-10V dim
Reference Ballast Wizard on website
or consult factory for other options.
Finish
C110 Painted aluminum
(low gloss)
C210 White white
(fine-textured
low gloss)
C099 Custom finish
# of Emergency Modules
(Blank) None
1SE 1 section
2SE 2 sections
XSE X sections
Options
ACG Adjustable cable grippers
BLK Black cord, cord manager and canopy (not available
with F3)
CP Chicago plenum (available with F1A only)
DL Damp location label
DU Dust cover
ELH Emergency through wiring w/separate feed
ELS Emergency through wiring w/single feed, shared neutral
ELS2 Emergency through wiring w/single feed, separate
neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
MCS Matching feed canopy at support
NEPP5D nLight enabled control module per row/zone
NYC New York City code
OJB Oset junction box
SCEP Sculptured end cap
SLP Sloped ceiling (for 10-45°, must be specified with
F2, ACG and OJB options)
XXXX Integrated sensor; choose options and obtain code
on page 2
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Peerless Bruno” are registered trademarks of Acuity Brands Lighting.
BRM3 Bruno Holes
Indirect T8
1
Type: ________________________
Bruno Holes
Project: ______________________
Indirect T8
Suspended BRM3
INTEGRATED NLIGHT MICRO SENSOR
Determine the appropriate sensor type, network type and sensor power source for your application. Enter the code in the Options section of the Catalog Number.
EXAMPLE: PDT1
Sensor Type (choose one)
ADC
nLight model
nES ADCX
PDT
nLight model
nES PDT7 ADCX
For more information about the Integrated nLight Micro Sensor, its capabilities and options, download the PDF guide at: PeerlessLighting.com/nLight-Sensor-Guide
*nLight-Enabled (network-ready) options include one RJ-45 connector on the luminaire and 10’ of Cat-5e cable and a splitter to control the entire luminaire row (depending on
wattage/voltage limitations). The Cat-5e cable drop is located in the same section as the sensor. For multiple zones, please contact techsupport@peerlesslighting.com.
Daylight Dimming
Specify 0-10V dimming ballast
No occupancy sensing
Daylight Dimming and/or Occupancy Detection
Specify 0-10v dimming ballast for daylight dimming
Specify fixed-output ballast for occupancy detection only
(daylight dimming disabled)
1* nLight-Enabled (Network-Ready) with Luminaire-Integrated Power Pack
10’ Cat-5e cable and splitter provided
2 Standalone Operation (No Networking) with Luminaire Integrated Power Pack
No Cat-5e cable provided
3* nLight-Enabled (Network-Ready) with Remote nLight Power Pack or nPanel
10’ Cat-5e cable and splitter provided
Order required remote nLight Power Pack or nPanel
separately through nLight (Acuity Brands Controls)
WEIGHTS & SUPPORT SPACING
Suspension spacing equals section length. Default location shown. Consult factory for stem mounting suspension spacing and alternate locations.
STANDARD SECTIONS
22 LBS
4’-0 3⁄8”
4’-1 5⁄8” O.A.
5
⁄8” standard flat end plates
4” optional sculptured end plates
Network Type & Sensor Power Source (choose one)
Key:
Support or feed location
•
x Please consult factory for sensor placement
38 LBS
54 LBS
PLAN VIEW
CONFIGURATIONS
PHOTOMETRICS
8’-0”
8’-1 1⁄4” O.A.
12’-0”
12’-1 1⁄4” O.A.
Tenon “L”, “T”, “X” and straight connectors available for suspended configurations.
Reference Pattern Connector Guide for additional details.
Actual performance may dier as a result of end-user environment and application.
1-LAMP T8
83.7% eciency
2385 delivered lumens
90.8% up / 9.2% down
2-LAMP T8
82.2% eciency
4686 delivered lumens
90.6% up / 9.4% down
3-LAMP T8
78.7% eciency
4487 delivered lumens
90.3% up / 9.7% down
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Peerless Bruno” are registered trademarks of Acuity Brands Lighting.