Peerless Lighting BRM3 User Manual

Type: ________________________
Bruno Holes
Indirect T8
SCEP Option
SPECIFICATIONS
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
Suspended BRM3
Project: ______________________
LAMPING OPTIONS
BRM3 - 1 BRM3 - 2 BRM3 - 3
8 1⁄4
1 3⁄4
1
2
8 1⁄4
1 3⁄4
1 3⁄4
1
2
1
2
8 1⁄4
SPECIFICATIONS
Construction
Nominal 8 1⁄4” x 1 3⁄4” rectangular housing is formed from cold-rolled steel. Die-cast end caps are mechanically attached with no exposed fasteners.
Reflectors
Die-formed specular reflector with 95% reflectance.
Shielding
Aluminum, die-formed drop pan with five 2 3⁄4” cylinder openings of down light feature. Also
available with acrylic opal overlay on top of down light openings.
Finish
Fine textured white polyester powder paint is standard. Drop pan always C110 painted Aluminum Finish. Consult factory for special finish requirements.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors included. UL and C-UL listed.
Luminaire Length
4’ 3⁄8”, 8’ and 12’ lengths in a single section for nominal support spacing at 4’, 8’ and 12’. For total luminaire length, add 5⁄8” for each flat end cap and 4” for each sculptured end cap. Using internal joiners, 4’, 8’ and 12’ sections can be joined to form longer rows.
CATALOG NUMBER
Examples: BRM3 2 32 SPR 40FT R8 277 GEB10 DCT LP835 F1/18 C210 SCEP — BRM3 3 32 SPR OPD 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21 C110
__________ __________ __________ __________ __________ _________ __________ __________ __________ __________
Luminaire
BRM3
______________ __________ ________________ ______________ ______________ ______________ _________________________________
Emergency Type
(Blank) None EC Emergency
EL1 Emergency
EN1 Emergency
Notes:
1 Not available in 347V 2 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified
# of Lamps in Cross Section
1 2 3
circuit
battery pack
battery pack w/night light circuit
Lamp Type
32 32W T8
2
Switching
SCT Single
DCT Dual
Lamp Color
L/LP No lamp
circuit
L/LPE No lamp. Wired
circuit
LP830 3000K 80+ CRI LP835 3500K 80+ CRI LP841 4100K 80+ CRI
Reference Lamp Chart on website or consult factory for other options.
Reflector
SPR Specular
reflector
for energy saving lamps.
Shielding
(Blank) None OPD Bae w/std
brightness opal diuser overlay
Luminaire Row Length
X FT
(4’ increments)
Mounting Type /
F1/ T-bar ceiling (universal
mounting bracket)
F1A/ T-bar ceiling (UMB with
integrated J-box)
F2/ Hard ceiling (horizontal
J-box)
F3/ Rigid stem
Maximum Section Length
R4 4’ section(s) R8 8’ section(s) R12 12’ section(s)
Overall Suspension
12 12” 15 15” 18 18” 21 21” 24 24” XX XX”
Overall suspension is measured from ceiling to bottom of luminaire.
Voltage
120 277 347
Ballast Type
GEB10 <10% THD Electronic ADEZ1 Advance Mark 10 dim DMHL3D1 Lutron Hi-Lume dim OSDIM1 Osram 0-10V dim
Reference Ballast Wizard on website or consult factory for other options.
Finish
C110 Painted aluminum
(low gloss)
C210 White white
(fine-textured low gloss)
C099 Custom finish
# of Emergency Modules
(Blank) None 1SE 1 section 2SE 2 sections XSE X sections
Options
ACG Adjustable cable grippers BLK Black cord, cord manager and canopy (not available
with F3)
CP Chicago plenum (available with F1A only) DL Damp location label DU Dust cover ELH Emergency through wiring w/separate feed ELS Emergency through wiring w/single feed, shared neutral ELS2 Emergency through wiring w/single feed, separate
neutrals
GLR Fusing (fast blow) GMF Fusing (slow blow) MCS Matching feed canopy at support NEPP5D nLight enabled control module per row/zone NYC New York City code OJB Oset junction box SCEP Sculptured end cap SLP Sloped ceiling (for 10-45°, must be specified with
F2, ACG and OJB options)
XXXX Integrated sensor; choose options and obtain code
on page 2
2246 5th Street, Berkeley, CA 94710 Tel: 510.845.2760 Fax: 510.845.2776 Email: techsupport@peerlesslighting.com PeerlessLighting.com
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Peerless Bruno” are registered trademarks of Acuity Brands Lighting.
BRM3  Bruno Holes
Indirect T8
1
Type: ________________________
Bruno Holes
Project: ______________________
Indirect T8
Suspended BRM3
INTEGRATED NLIGHT MICRO SENSOR
Determine the appropriate sensor type, network type and sensor power source for your application. Enter the code in the Options section of the Catalog Number.
EXAMPLE: PDT1
Sensor Type (choose one)
ADC
nLight model nES ADCX
PDT
nLight model nES PDT7 ADCX
For more information about the Integrated nLight Micro Sensor, its capabilities and options, download the PDF guide at: PeerlessLighting.com/nLight-Sensor-Guide *nLight-Enabled (network-ready) options include one RJ-45 connector on the luminaire and 10’ of Cat-5e cable and a splitter to control the entire luminaire row (depending on wattage/voltage limitations). The Cat-5e cable drop is located in the same section as the sensor. For multiple zones, please contact techsupport@peerlesslighting.com.
Daylight Dimming
Specify 0-10V dimming ballast No occupancy sensing
Daylight Dimming and/or Occupancy Detection
Specify 0-10v dimming ballast for daylight dimming Specify fixed-output ballast for occupancy detection only (daylight dimming disabled)
1* nLight-Enabled (Network-Ready) with Luminaire-Integrated Power Pack
10’ Cat-5e cable and splitter provided
2 Standalone Operation (No Networking) with Luminaire Integrated Power Pack
No Cat-5e cable provided
3* nLight-Enabled (Network-Ready) with Remote nLight Power Pack or nPanel
10’ Cat-5e cable and splitter provided Order required remote nLight Power Pack or nPanel separately through nLight (Acuity Brands Controls)
WEIGHTS & SUPPORT SPACING
Suspension spacing equals section length. Default location shown. Consult factory for stem mounting suspension spacing and alternate locations.
STANDARD SECTIONS
22 LBS
4’-0 3⁄8
4’-1 5⁄8” O.A.
5
8” standard flat end plates
4” optional sculptured end plates
Network Type & Sensor Power Source (choose one)
Key:
Support or feed location
x Please consult factory for sensor placement
38 LBS
54 LBS
PLAN VIEW
CONFIGURATIONS
PHOTOMETRICS
8’-0”
8’-1 1⁄4” O.A.
12’-0”
12’-1 1⁄4” O.A.
Tenon “L”, “T”, “X” and straight connectors available for suspended configurations. Reference Pattern Connector Guide for additional details.
Actual performance may dier as a result of end-user environment and application.
1-LAMP T8
83.7% eciency 2385 delivered lumens
90.8% up / 9.2% down
2-LAMP T8
82.2% eciency 4686 delivered lumens
90.6% up / 9.4% down
3-LAMP T8
78.7% eciency 4487 delivered lumens
90.3% up / 9.7% down
2246 5th Street, Berkeley, CA 94710 Tel: 510.845.2760 Fax: 510.845.2776 Email: techsupport@peerlesslighting.com PeerlessLighting.com
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Peerless Bruno” are registered trademarks of Acuity Brands Lighting.
BRM3  Bruno Holes
Indirect T8
2
Loading...