PEERLESS WBV SERIES, WV SERIES, WBV-03-08, WBV-03-110, WBV-04-095 Installation, Operation & Maintenance Manual

...
WBV/WV
Boilers
Installation,
Operation
Maintenance Manual
PEERLESS"
Packaged or Knockdo ,
8 Sizes 3-5 Sections .60 to 2.00 GPH Input 82% to 86% AFUE
Natural Draft (chimney) Venting
Factory Assembled Sections on Knockdown Boilers
Reduces Installation Time
WBV in 3 and 4 Section for Hot Water or Steam
Convertible from Rear to Top Flue for Venting Flexibility
WV in 5 Section for Hot Water
Top Flue Only
High Efficiency Flame Retention Burners
Choice ofBeckett, Carlin or Riello
Full Plate Swing-Out Door
Standard on All Boilers
Provides Easy Access to Combustion Chamber Area jbr Cleaning and Servicing
Large Water Content, Wet Base Section Design
Reduces On/O_'f'Cycling
Steel Push Nipples
Provide a Permanent Water Tight Seal Between Sections
Unaffected by Petroleum and Other Contaminants
Deluxe Insulated Enameled Steel Jacket
Reduces Boiler Heat Loss
Safety Controls
Prob_ or Floai Type Low Water
Cut-Qff Approved on Steam Boilers
Tankless Coils
For Domestic Hot Water Production on Hot Water Boilers
As an ENERGY STAR _ Partner Peerless Healer Comparl¥ Has delerr#med that certain f_rin9 rales of this product mee_ Ihe ENERGY STAR" guidelines
for energy efficiency
Honeywell Operating Controls
Taco 007 Circulator on Packaged Water Boilers
Probe Type LWCO on Packaged Steam Boilers
omp\e te J
Tankless Coils
Barometric Draft Damper
Grundfos Circulator on Packaged Water Boilers
Float Tltpe LWCO on Packaged Steam Boilers
/'_'<'rl(,._.s 1 lec_ttq Compony is p&_a.s_d lo q[]_'r otlt _ @the" most coml)reh_.t_siv¢" u,tu_c_ttty l)i-o()l(lms ill the. hlHztstry. All P(x'rless tz!sidential cckst iron boilers i11chtde a.fidl orl(! !F.ar It,azTcUlty. A limiled.
li]_'litllt" It,(tt r(iNly is provided jbr Ihe cc_st iron sections q[ Pcerless rt_sidetltial hol [t,(llt_!t boilet_. P_'_tl('._5 _tl._o i)tol,id<!s o linlit_'d. 11!11_](fOf [tl_UTO/l/t] Oil I_l(_ C€ISt irotl SeCtiotls Q[ il5 I'('si_lt,llllol sl(?at]l boil_'t._. Fit,(, ariel !('n !j('cw _5\'l_!lld('d [t,olv_lltli('s oil parts €Old lclbor nre IIOIL! (Ip(lilflblt'. P[('_Is_' COllStll/ ]_'('rl_'y;5 [ It'(tlt,r ('OmlXUl!lJbr compIt'lt" tt,(ltT_ttll[I il!fbrmation.
PEGRLESS _
CAST IRON BOILERS
Peerless Heater Company * 231 North Walnut Street Boyertown, PA 19512-1021 * 610-367-2153 www.peerless-heater.com
FAB WBV RI (5!02 5M)
prlrlf(?(l _rl U S A
Background Information - Draft Requirements
Modern boilers operate with higher efficiencies than older boilers. Smaller flueways, as well as bars, pins and fins are designed into modern boilers to transfer as much heat as possible from the hot gases to the
water or steam and prevent heat loss up the chimney. However, these design features result in higher pres- sure, or draft loss, in the boiler.
This draft loss must be taken into account when installing an oil boiler into a new or old chimney. New chimneys are less likely to have poor draft. However, they must have sufficient draft to support combus- tion. A -.06" draft is desirable and preferred. Older, unlined chimneys may require a replacement liner to have them perform well enough to support combustion.
An example follows:
Chimney Draft
Old installation New installation
-.04" -.04 °
Comments
No change, but older chimneys (especially unlined ones) have
leaks which reduce draft.
Boiler Design Pressure Drop
+.01" +.04"
Required for mandated efficiency increases.
Draft Over Fire -.03" 0.00"
The old installation would have
had a higher temperature in the chimney [as high as 800 degrees vs. 400 degrees F], which would
increase the draft.
The above readings are 'cold' readings [before the boiler and chimney are heated up].
A-.01 _ to -.02 _ minimum draft over fire is required for a good installation where no oil fumes
would be present. The draft would vent them up the chimney.
The above discussion which concerns draft in the chimney and draft loss in the boiler, is incomplete with- out discussing the effect of draft on the burner. Very simply, increasing the fuel usage [higher gallonage] on a unit which has multiple firing rates, requires more air for combustion and a higher draft loss in the boiler.
As an example, increasing the firing rate 1/4 gallon will increase the draft loss in the unit by approximately +.01". The actual burner used on a particular boiler also effects the draft and smoke condition. The use of
a burner supplied by Peerless Heater Company would assure you of a quality, trouble free installation.
INSTALLATIONINSTRUCTIONS- SERIESWBVandWV
Readcarefullybeforebeginningwork.It willsavetime.Studytheincludeddrawings.
Theequipmentshallbeinstalledinaccordancewiththoseinstallationregulationsin forceinthe localareawherethe installationisto be made,including the currenteditionof NFPA-31.Theseshallbecarefullyfollowedinall cases.Authoritieshavingjurisdictionshall beconsultedbeforeinstallationsare made.
Theboiler mustbe installedbya qualifiedcontractor. Theboiler warrantycanbe voidedifthe boileris notinstalled,maintainedandservicedcorrectly.
A - ACCESSIBILITYCLEARANCES
1- Toprovidefor reasonableconditionsofaccessibility,thefollowingminimumclearancesarerecommended.
a. TopOutletFlue:At least24" in thefront,rear andon bothsides. b. RearOutletFlue:At least24" infrontand bothsides;at least30" inthe rear.
B- AIRFORCOMBUSTIONANDVENTILATION
1- Be certainadequatefacilitiesareavailableto provideairforsatisfactorycombustionand ventilation.
2 -Appliances Locatedin UnconfinedSpaces.
a. Forinstallationsin unconfinedspaceswith conventionalconstructionand larger areassuchas basements,the supplyof airfor combustionand
ventilationcan usuallybe consideredadequate.
3 - AppliancesLocatedin ConfinedSpaces.
a. If all airfor combustionandventilationis to come fromwithinthe building:twoopenings,onenearthe ceilingand one nearthe floor of the boiler
roomshallbe providedwiththe minimumfree areaof eachopeningequalto 140sq. in. pergallonof oilburned.
b. If allairfor combustionandventilationisto comefromoutsidethe building:twoopenings,onenearthe ceilingandone nearthefloorofthe boiler
roomshallbeprovidedwiththe minimumfreeareaof eachopeningequalto 35 sq.in. pergallonof oil burned. If ductsare usedto conveythe air,areasof 35 sq. in.pergallon ofoil burnedfor verticalductsor 70 sq.in.pergallonof oil burnedforhorizontal
ductsaretobe provided.Ductsshallhavethesameareaasthe freeareaof theopeningsto whichtheyare connected.
C- SETTINGTHE BOILER
1- TheWBV/WVBoilerSectionsare FactoryAssembledwiththeTargetWallShippedinplace.Providealevelfoundation,locatedas closeas possibleto
the center of the heatingsystemandtothe chimney.TheWBV/WVSeries is availableasa completepackage,or in a knockeddownform. Referto
page5 for explodedviewof boilerif on-the-jobassemblyisrequired. 2-This boileris suitableforuseon combustibleflooring,providedtheboiler is not setoncarpetand a metal drippan isplacedunderthe appliance. 3- TheWBV-03andWBV-04boilermodelsmaybe installedas a rearflueoutletunit ora topflue outletunit.This maybedonebymountingthe FlueCollar
Adapter(Item14)to eithertherear boilersectionfora rearflueapplication,orto the FlueCollectorCoverPlate(Item11)fora topflueapplication.The
RearOutletCoverPlate(Item13) isthenusedto closetheremainingopening.OnPackagedUnitsthe largeknockoutintheTopJacketPanelmustbe
removedtoconvertto a topflue application.NOTE:TheWV-05boilermodelisonlyavailableasa top flueoutletunit. 4- Open trim carton.RemoveFlueCollectorCoverPlateandBlanketSeal(Items10 and 11)and attachwith thefour (4)5/16" x 1_/2"studs,nutsand
washersprovided.Attacheitherthe FlueCollarAdapter(Item14)or the OutletCoverPlate(Item 13)to the FlueCollectorCoverPlatewiththe nuts andwashersprovidedmakingsurethe ropeseal(Item12)is in place.Attachthe remainingFlueCollaror CoverPlatetothe rearsectionwithfour(4)
5/r6"bolts andwashers.
5- If a tanklesscoilisused,(Item9)installaspictured.WaterBoiler- frontsectionopening.SteamBoiler- rearsectionopening.Forsuggestedpipingof
tanklesswaterheatersreferto Figures4 and5.
6- Whena tanklesscoilis notemployed,covertheopeningwithcoverplate(Item 7 or 16).
D- JACKETASSEMBLY
1- If boiler is tobe installedwitharear flueoutlet,removethesquareknock-outinthe backpanelthenattachtobosseson middleof backsectionwith
two1/4" x 3/8"machinescrewsprovided.The backpanelhas two 5/16"dia.holesclosetothe centerofthe panel.
2 - Attach boththe left and rightsidepanelstothe backpanel andsecurewithsheetmetalscrews. 3 - RemoveBurnerMountingPlate (Item5) andmakecertainthe TargetWall(Item2) and CerafeltLineron floorofboilerin frontoftarget wall(Item3)
arefirmly in place.
4- Removethetwo(2)knockoutsinthefrontjacketpanelwhichwill allowclearanceforthe hinge.Placethefrontjacketpanelonthe blockandattachthe
leftand rightsidepanelsin the samemannerastheyareattachedto thebackpanel.Attachthe CombustionChamberCoverPlate.
5- ReinstallCombustionChamberCoverPlate. 6- If boiler is to be installedwitha top flueoutlet,removetheknock-outinthe topjacketpanelthensecurewith sheetmetalscrews.
E - PIPING
DONOTPIPEBOILERBEFOREJACKET_SINSTALLED.
1- See Figures1 and2 forsuggestedpipingtothe boiler.
2- Makeupcold watersupplyconnectiontothe boiler.
3- Installpressuregaugeor pressure-temperaturegaugein tappingprovided.See page3.
4- Plugal_opentappingsin the boilerandfill with water.Applyapproximatelythirty (30) poundspressure.Checkto make certainthat all iointsand
fittingsarewatertight.
5- Afteralljoints andconnectionshavebeenprovenwatertight,removeooldwatersupplyandplugsfromalltappingsthataretobe used,Seepage3
fortappinglocations.
6- Returnwater pipingmustbe donein sucha mannertoallowelearaooeofthe doortothe circulatorstandpipe
orother pipingwhenopeningandclosingthedoor.Peerlesssuggestsusinga 11/4"tee,a90° streetelbow,and 11/4"x 5" pipenippleinthe
returntappingbeforea verticalcirculatorstandpipeis usedas shownon page3.
HOTWATER
v
Thesupplyand returnconnectionsshouldbe sizedto suitthe system.A 1r/2" to 11/4" reducingcouplingmaybeusedon the
returnwherethe systempipingis 11/2".
Thesupplyshouldbe outof thetop ofthe backsectionand returnto thebottomofthe frontsection.Thereisa 3/4"tappingin
the top oftheback sectionfor airelimination,
FIGURE1
STEAM
Boiler Model Supply
No. Riser Equalizer
WBV-.03 1-2" 11/4" WBV-04 1- 2" 11/4"
Thereturnfromsystemshouldalwaysenterequalizerthrough HartfordLoop,2" to 4" belownormalwaterline,
RGURE2
_TER
FIGURE3
Note:If boileris to be usedinconjunctionwitha refrigera-
tionsystem,thechilledmediumshallbepipedin par- allelwithboilerandpropervalvesappliedtoprevent
thechimedmediumfromenteringtheboiler.Referto
Figure3. Whentheboilerisconnectedtoheatingcoilslocated
inairhandlingun_S,the boilerpipingsystemmustbe
equippedwithflowcontrolvalvesor otherautomatic devicestopreventgravitycirculationof theboiler
waterduringthe coolingcycle.
WBV/WVWATERBOILER
SAFETY RELIEF VALVE
.35" VALVE
DRAIN VALVe"
--2 11/16" 3 1/16" _
6" REAR FLUE "C"
_(WBV-O3,
WBV-04 ONLY)
LINE
R_
1
1 I/2" SUPPLY_
OPTIONAL
TANKLESS
HEATER x
LIMIT -
TEMPERATURE
PRESSURE GAUGE _'
1_3/_ I_-
APPROX '
-_-_2,18"7
1 114"
' "C'"DOLATO"
28 I/2"
DRAIN
VALVE
FRONT
Boiler Jacket RearofJackettoC/L Top/Rear Model Depth ofTopFlueOutlet FleaSize
Number "A.... B.... C"
WBV-03-085/110 141/8" 71h6" 6" WBV-04-1251150 18%" 91h6" 6" WV-05-175/200 22%" 111116" 7" (TopOnly)
WBVSTEAMBOILER
SKIM
PROBE
FLOAT LWCO
[
ALTERNATE
29 7/8"
_OP_ONAL
TANKLESS J
HEATER
-FLOOR LINE
_2 11/16"
_6"
_REAR
FLUE
-C-
'_SAFETY
VALVE
1 I/4" ALTERNATE
RETURN OR DRAIN
VAL'AE.
g_
Boiler Model
Number
Jacket Rear of Jacketto C/L Top/Rear
Depth of Tap FleaOutlet Flue Size
"A.... B" "C"
WBV-03-085/110 153/4" 87/8" 6" WBV-04-125/150 19314" 10%" 6"
3