Peerless-AV STL637 Installation [en, es, fr]

Installation and Assembly: Peerless Ultra-Thin Articulating
Mount for 32" to 46"* Flat Panel Displays
Model: SUA737
*Display Compatibility Requirements
• Depth of display must be less than 2".
• The depth of this mount (1.29") may not provide suffi cient space for proper ventilation on some displays. Please refer to the manufacturer's requirements for mounting your display before installation.
• The display must have a fl at mounting surface, or the mounting holes need to be on the furthest back surface of the display.
• Input/Output connection must be properly oriented to accommodate mounting 1.29" from the wall.
2300 White Oak Circle • Aurora, Il 60502 • (800) 865-2112 • Fax: (800) 359-6500 • www.peerlessmounts.com
Max UL Load Capacity: 60 lb (27.2 kg)
ISSUED: 12-15-11 SHEET #: 095-9371-2 03-08-12
Note: Read entire instruction sheet before you start installation and assembly.
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings
contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact your local distributor.
• This mount is designed to attach the display 1.29" from the wall. Please refer to manufacturer's installation guide
recommendations for required distance from wall to avoid risk of injury or property damage.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Never exceed the Maximum UL Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of
an "edge to edge" stud fi nder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal
injury.
• This product was designed to be installed on the following wall construction only; WALL CONSTRUCTION HARDWARE REQUIRED
• Wood Stud Included
• Wood Beam Included
• Solid Concrete Included
• Cinder Block Included
Brick Contact Qualifi ed Professional (not evaluated by UL)
• Other or unsure? Contact Qualifi ed Professional
Tools Needed for Assembly
• stud fi nder ("edge to edge" stud fi nder is recommended)
• phillips screwdriver
• drill
• 5/16" (8mm) bit for concrete and cinder block wall
• 5/32" (4mm) bit for wood stud wall
• level
Table of Contents
Parts List.................................................................................................................................................................................3
Wall installation ...................................................................................................................................................................4, 5
Installing Adapter Brackets to Display ....................................................................................................................................6
Mounting Flat Panel Display ...................................................................................................................................................7
2 of 23 ISSUED: 12-15-11 SHEET #: 095-9371-2 03-08-12
Before you begin, make sure all parts shown are included with your product.
A
K
Parts List
Description Qty. Part #
wall arm assembly 1 046-P1260
C wood screws 2 520-1202 D concrete anchors 2 590-0320
M4 x 6mm screw
E
security driver
F
4mm allen wrench
G H fastener cap 2 590-1324
I cable anchor 1 046-P1134
J cable clip 1 046-P1138
cable tie 2 046-0136
L
M5 x 12mm screw 4
M
M5 x 25mm screw 4
N
M6 x 12mm screw 4
O
M6 x 25mm screw 4
P
M8 x 12mm screw 4
Q
M8 x 25mm screw 4
R
3/4" spacer 4
S
flat washer 4
Parts may appear slightly different than illustrated.
2 1 1
520-1006 560-1133 560-9646
560-1732 560-1733 560-1734 560-1735 560-1736 560-1737 540-1059 540-9478
A
CDE F
HI
G
J
K
LMN O P Q R S
3 of 23 ISSUED: 12-15-11 SHEET #: 095-9371-2 03-08-12
Installation to Single Wood Stud Wall
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.
Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
Use a stud fi nder to locate the edges of the stud. Use of an edge-to-edge stud fi nder is highly recommended.
1
Based on their edges, draw a vertical line down the stud’s center. Measure 4.8" (122mm) left or right from stud's center to determine center of display mounting plate. Place wall arm (A) on wall as template, level, and mark the center of two mounting holes. Top mounting hole will be 6.66" above the center of display mounting plate as shown in fi gure 1.1.
Drill two 5/32" dia. holes to a minimum depth of 2.5". Secure wall arm (A) to wall with two wood screws (C) as shown in fi gure 1.2. For cable management option, install cable anchor (I) to bottom mounting hole with wood screw (C). NOTE: Be sure arrow is pointing up when mounting wall arm (A) to wall as shown in fi gure 1.1. Level, then tighten all fasteners.
Insert two fastener caps (H) into wall plate mounting holes.
g. 1.1
4.8"
(122mm)
6.66"
(169mm)
= CENTER OF DISPLAY
MOUNTING PLA TE
ARROW
DISPLAY
g. 1.2
C
H
A
I
4 of 23 ISSUED: 12-15-11 SHEET #: 095-9371-2 03-08-12
Installation to Solid Concrete or Cinder Block
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
Place wall arm (A) on wall as template, level,
1
and mark the center of two mounting holes. Top mounting hole will be 6.66" above the center of display mounting plate as shown in fi gure 1.1 on page 4. Drill two 5/16" dia. holes to a minimum depth of 2.5". Insert anchors (D) into holes fl ush with wall as shown. Secure wall arm (A) to wall with two wood screws (C) as shown in fi gure 1.3. For cable management option, install cable anchor (I) to bottom mounting hole with wood screw (C). NOTE: Be sure arrow is pointing up when mounting wall arm assembly (A) to wall as shown in fi gure
1.1. Level, then tighten all fasteners. Insert two fastener caps (H) into wall plate mounting
holes.
WARNING
• Tighten screws so that wall plate is fi rmly attached,
but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other nishing material. If mounting to concrete surfaces covered with a fi nishing surface is unavoidable (not evaluated by UL), the fi nishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16mm), custom fasteners must be supplied by installer (not evaluated by UL).
1
Drill holes and insert anchors (D).
2
A
C
Place plate (A) over anchors (D) and secure with screws (C).
3
Tighten all fasteners.
SOLID CONCRETE
CINDER BLOCK
D
C
H
A
concrete surface
D
D
plate
CUTAWAY VIEW
wall
plaster/ dry wall
INCORRECT CORRECT
concrete
wall
plate
plaster/ dry wall
concrete
I
g. 1.3
5 of 23 ISSUED: 12-15-11 SHEET #: 095-9371-2 03-08-12
For VESA 200 x 200 mounting pattern
WARNING
• Tighten screws so display brackets are fi rmly attached to display. Do not tighten with excessive force.
Overtightening can cause stress damage to screws, greatly reducing their holding power and possibly causing screw heads to become detached. Tighten to 40 in. • lb (4.5 N.M.) maximum torque.
• If screws don't get three complete turns in the display inserts or if screws bottom out and bracket is still not tightly
secured, damage may occur to display or product may fail.
Insert two 12mm screws (L, N, O) into top two holes of display, leaving approximately 1/4" (6mm) of exposed
2
thread. Hook screws onto keyslots of front plate as shown.
1/4"
L, N, O
FRONT PLATE
Insert two 12mm screws (L, N, O) into bottom holes of adapter plate as shown. Tighten all fasteners.
2-1
L, N, O
6 of 23 ISSUED: 12-15-11 SHEET #: 095-9371-2 03-08-12
Roll Adjustment
Adapter plate may be rolled +/- 5°. Roll locking screw may be tightened or loosened using 4mm allen wrench (G).
4
NOTE: Do not remove roll locking screw.
CAUTION
• Do not tighten joint screws. Doing so may cause
damage to screws, greatly reducing their holding power.
JOINT SCREWS
ROLL LOCKING SCREW
Cable Management
Cables may be routed using cable clip (J).
5
Slip cable clip (J) onto bottom of center joint as shown in fi gure 5.1 and secure cables to cable clip using cable tie (K) as shown in fi gure 5.2.
Secure cables to cable anchor (I) using cable tie (K) as shown below.
I
CENTER
J
JOINT
CABLES
K
CABLES
K
g. 5.1
g. 5.2
7 of 23 ISSUED: 12-15-11 SHEET #: 095-9371-2 03-08-12
All other brand and product names are trademarks or registered trademarks of their respective owners.
© 2012, Peerless Industries, Inc. All rights reserved.
Peerless Industries, Inc.
2300 White Oak Circle
Aurora, Il 60502
www.peerlessmounts.com