Peerless Industries ST630, ST630P, ST630P-S User Manual

Installation and Assembly:
©
U
L
USC
SmartMount™ Universal Tilt Wall Mount for 10" - 24" (25 - 61 cm) LCD Flat Panel Screens
Models: ST630P, ST630P-S, ST630, ST630-S
Features:
• Fits 10" - 24" (25 - 61 cm) LCD at panel screens
• One-touch tilt for effortless positioning and adjustment of the screen Max Load Capacity: 80 lb (36.3 kg)
ISSUED: 02-05-09 SHEET #: 201-9421-9 06-03-09
Note: Read entire instruction sheet before you start installation and assembly.
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Never exceed the Maximum Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of an "edge to edge" stud nder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury.
• This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION HARDWARE REQUIRED
 •Wood Stud Included
Wood Beam Included
Solid Concrete Included
Cinder Block Included
•Metal Stud Do not attach except with Peerless Metal Stud Accessory Kit - ACC215;
•Brick Contact Qualied Professional
•Other or unsure? Contact Qualied Professional
Tools Needed for Assembly
stud nder ("edge to edge" stud nder is recommended)
• phillips screwdriver
drill
• 5/16" (8 mm) bit for concrete and cinder block wall
• 5/32" (4 mm) bit for wood stud wall
• level
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Single Wood Stud Wall .....................................................................................................................................4
Installation to Solid Concrete or Cinder Block ........................................................................................................................5
Attaching Adapter Plate to Flat Panel Screen ........................................................................................................................6
Installing and Removing Flat Panel Screen............................................................................................................................7
2 of 23
ISSUED: 02-05-09 SHEET #: 201-9421-9 06-03-09
ST630P ST630P-S
ST630 ST630-S
Description Qty Part #
Part # Part # Part #
A
hook bracket 1 095-1346 095-4346 095-1346 095-4346
B
tilt assembly 1 095-0359 095-0360 095-0359 095-0360
C
concrete anchor 2 590-0320 590-0320 590-0320 590-0320
D
M4 x 10 mm phillips screw 4 504-9012 504-9012 504-9012 504-9012
E
M4 x 20 mm phillips screw 4 504-9020 504-9020 504-9020 504-9020
F
retaining spacer 4 590-5005 590-5005 590-5005 590-5005
G
#14 x 2.5" wood screw 2 5S1-015-C03 5S1-015-C03 5S1-015-C03 5S1-015-C03
H
M5 x 6 mm screw 1 520-1023 520-1023 520-1114 520-1114
I
security driver 1 - - 560-1133 560-1133
Parts List
Before you begin, make sure all parts shown are included with your product.
Parts may appear slightly different than illustrated.
A
B
C
D
F
E
H
I
3 of 23
ISSUED: 02-05-09 SHEET #: 201-9421-9 06-03-09
G
Installation to Single Wood Stud Wall
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Tighten wood screws so that wall plate is rmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud nder is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install­ers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
Use a stud nder to locate the edges of the stud. Use of an edge-to-edge stud nder is highly recommended.
1
Based on its edges, draw a vertical line down the stud’s center. Place tilt assembly (B) on wall as a template, making sure that the two mounting holes are over the stud centerline. Level tilt assembly, and mark the center of the two holes. Drill two 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Make sure that the tilt assembly is level, secure it using two #14 x 2.5" wood screws (G) as shown.
Skip to step 2.
G
B
4 of 23
ISSUED: 02-05-09 SHEET #: 201-9421-9 06-03-09
Installation to Solid Concrete or Cinder Block
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components.
Make sure that tilt assembly (B) is level, use it as a
1
template to mark two mounting holes. Drill two 5/16" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (C) in holes ush with wall as shown (right). Place tilt assembly over anchors and secure with two #14 x 2.5" screws (G). Level, then tighten all fasteners.
WARNING
• Tighten screws so that wall plate is rmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly to load-bearing concrete.
• Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other nishing material. If mounting to concrete surfaces covered with a nishing surface is unavoidable, the nishing surface must be counter bored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).
1
Drill holes and insert anchors (C).
2
B
G
Place plate (B) over anchors (C) and secure with screws (G).
3
Tighten all fasteners.
SOLID CONCRETE
CINDER BLOCK
concrete surface
C
C
plate
CUTAWAY VIEW
wall
plaster/ dry wall
INCORRECT CORRECT
concrete
wall
plate
plaster/ dry wall
concrete
5 of 23
G
B
ISSUED: 02-05-09 SHEET #: 201-9421-9 06-03-09
C
Attaching Adapter Plate to Flat Panel Screen
WARNING
• If screws don't get three complete turns in the screen inserts or if screws bottom out and bracket is still not tightly secured, damage may occur to screen or product may fail.
FOR VESA
2
Choose hole pattern as shown below. Attach hook plate (A) to back of screen using four M4 x 10 mm screws (D) as shown below.
*Note: If hole pattern is in a pocket, attach hook plate (A) to back of screen using four M4 x 20 mm screws (E) and four retaining spacers (F) as indicated below.
®
75 MOUNTING PATTERN:
A
FOR VESA® 100 MOUNTING PATTERN:
Choose hole pattern as shown below. Attach hook plate (A) to back of screen using four M4 x 10 mm screws (D) as shown below.
A
D
*For screens with a hole pattern in a pocket, spacers (F) go
between hook plate (A) and screen.
F
6 of 23
D
ISSUED: 02-05-09 SHEET #: 201-9421-9 06-03-09
Installing and Removing Flat Panel Screen
Attach screen to tilt assembly (B). Tighten
3
M5 x 6 mm screw (H) to lock screen to tilt assembly.
Note: For security models, use security driver (I) to
tighten M5 x 6 mm screws (H).
To remove screen from mount, loosen screw (H) and lift screen off of mount.
WARNING
• Do not lift more weight than you can handle. Use ad­ditional man power or mechanical lifting equipment to safely handle placement of the screen.
• Failure to lock hook plate (A) with screw (H) can cause screen to come off mount if hit accidentally.
• Do not tighten screws with excessive force. Overtightening can cause damage to mount. Tighten screws to 20 in. • lb (2.26 N.M.) maximum torque.
Adjust tension knob on right side of mount shown in
4
gure 4.1 to desired tension to balance your screen size and weight.
Push or pull from top or bottom of screen to adjust tilt as shown in gure 4.1. The tilt can be adjusted to a maximum of 15° forward or 5° backward.
SCREEN
H
A
B
g.3.1
CAUTION
• Do not tighten screws with excessive force. Overtightening can cause damage to mount. Tighten screws to 40 in. • lb (4.5 N.M.) maximum torque.
• Be careful not to pinch ngers when pushing screen from the bottom.
TENSION KNOB
g.4.1
7 of 23
All other brand and product names are trademarks or registered trademarks of their respective owners.
ISSUED: 02-05-09 SHEET #: 201-9421-9 06-03-09
© 2009, Peerless Industries, Inc. All rights reserved.
Peerless Industries, Inc.
3215 W. North Ave.
Melrose Park, IL 60160
www.peerlessmounts.com
Loading...
+ 16 hidden pages