Peerless-AV PSP5-W Installation

Installation and Assembly:
Universal Projector Wall Arm
Models: PSTA-028, PSTA-028-W, PSTK-028, PSTK-028-W
Max UL Load Capacity: 50 lb (22.7 kg)
2300 White Oak Circle • Aurora, Il 60502 • (800) 865-2112 • Fax: (800) 359-6500 • www.peerless-av.com
ISSUED: 03-23-09 SHEET #:055-9260-8 04-25-13
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Never exceed the Maximum Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of an "edge to edge" stud fi nder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury.
• This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION HARDWARE REQUIRED
Wood Stud Included
Wood Beam Included
Solid Concrete Included
Cinder Block Included
Metal Stud Contact Qualifi ed Professional (not evaluated by UL)
Brick Contact Qualifi ed Professional (not evaluated by UL)
Other or unsure? Contact Qualifi ed Professional (not evaluated by UL)
Tools Needed for Assembly
• stud fi nder ("edge to edge" stud fi nder recommended)
• level
• drill
• 5/32" drill bit for wood studs
• 5/16" dill bit for solid concrete and cinder block
• phillips screwdriver
Accessories
• ACC-MIS550 (not evaluated by UL) (cable accessory kit)
• ACC020 (not evaluated by UL) (Projector Security Cable kit)
• WBK100 (not evaluated by UL) (wall plate accessory kit )
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Wood Stud .................................................................................................................................................... 4,6
Installation to Solid Concrete/Cinder Block ....................................................................................................................... 5,7
Assembly of Adjustment Tube ...............................................................................................................................................8
Installing Projector Mount ......................................................................................................................................................8
Routing Cables .......................................................................................................................................................................9
Visit the Peerless Web Site at www.peerless-av.com
2 of 9
ISSUED: 03-23-09 SHEET #:055-9260-8 04-25-13
IMPORTANT: Read instruction sheet before you start installation and assembly.
Before you start check the parts list to insure all of the parts shown are included.
Parts List
Description Qty Part #
A wall arm 1 055-1909 055-2909 055-1909 055-2909 B carriage 1 056-1332 056-2332 056-1332 056-2332 C 4 mm allen wrench 1 560-9646 560-9646 560-9646 560-9646 D M5 x 10 mm serrated socket pin screw 4 520-1063 520-2063 520-1063 520-2063 E #14- x 2.5 phillips head wood screw 4 5S1-015-C03 5S1-015-C04 5S1-015-C03 5S1-015-C04 F tube cap 1 590-1274 590-1274 590-1274 590-1274
G concrete anchor 4 590-0320 590-0320 590-0320 590-0320
H 1/4"-20 phillips screw 2 520-1054 520-2069 520-1054 520-2069
I 1/4"-20 at washer 2 540-1078 540-2078 540-1078 540-2078 J projector mount 1 PRGS-UNV PRGS-UNV-W PRGS-UNV PRGS-UNV-W K wall plate 1 055-1923 055-2923 L 5/16 -18 x 1/2 carriage bolt 4 520-9207 520-2047
M 5/16 - 18 serrated anged lock nut 4 530-1016 530-2016
NOTE: Some parts may appear slightly different than illustrated.
A
B
PSTA-028 Part #
PSTA-028-W Part #
PSTK-028 Part #
PSTK-028-W
C
D
E
J
F
K
G
H
L
I
M
Visit the Peerless Web Site at www.peerless-av.com
3 of 9
ISSUED: 03-23-09 SHEET #:055-9260-8 04-25-13
Installation to Wood Stud Walls for PSTA-028, PSTA-028-W Models
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
Note: For PSTK-028 models, refer to page 6.
1
Use a stud fi nder to locate the edges of the stud. Use of an edge-to-edge stud fi nder is highly recommended. Based on its edges, draw a vertical line down the stud’s center. Place wall arm (A) on wall as a template. Mark the center of the four mounting holes. Drill four 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Secure wall arm (A) to wood stud using four #14 x 2-1/2" wood screws (E) as shown.
Optional: Rotate wall arm 180° to position the arm closer to the ceiling. Skip to Step 2.
Visit the Peerless Web Site at www.peerless-av.com
E
4 of 9
A
ISSUED: 03-23-09 SHEET #:055-9260-8 04-25-13
Installation to Solid Concrete or Cinder Block Wall for PSTA-028, PSTA-028-W Models
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete surface in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components.
Note: For PSTK-028 models, refer to page 6.
1
Drill four 5/16" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (G) in holes fl ush with wall as shown. Attach wall arm (A) using four #14 x 2 -1/2" wood screws (E) as shown in Illustration A and 1, 2, and 3. Tighten all fasteners. Optional: Rotate wall arm 180° to position the arm closer to the ceiling.
Skip to Step 2.
1
Drill holes and insert anchors (G).
2
A
concrete surface
G
WARNING
• Tighten wood screws fi rmly, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
• Concrete anchors are not intended for attachment to concrete wall covered with a layer of plaster, drywall, or other fi nishing material. If mounting to concrete wall covered with plaster/drywall is unavoidable (not evaluated by UL), plaster/drywall (up to 5/8" thick) must be counterbored as shown right. If plaster/ drywall is thicker than 5/8", custom fasteners must be supplied by installer (not evaluated by UL).
INCORRECT CORRECT
plate
CUTAWAY VIEW
wall
plaster/ dry wall
concrete
wall
plate
plaster/ dry wall
concrete
E
Place plate (A) over anchors (G) and secure with screws (E).
3
Tighten all fasteners.
SOLID CONCRETE
G
E
A
G
CINDER BLOCK
Visit the Peerless Web Site at www.peerless-av.com
5 of 9
Illustration A
ISSUED: 03-23-09 SHEET #:055-9260-8 04-25-13
Installation to Wall Plate For PSTK-028, PSTK-028-W Models
Secure wall arm (A) to wall plate (K) using four carriage bolts (L) and lock nuts (M).
1
L
M
A
K
Installation to Wood Stud Wall for PSTK-028, PSTK-028-W
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
Use a stud fi nder to locate the edges of the stud. Use of an edge-to-edge stud fi nder is highly recommended.
1-1
Based on its edges, draw a vertical line down the stud’s center. Place wall plate (K) on wall as a template. Mark the center of the four mounting holes. Drill four 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Secure wall plate (K) to wood stud using four #14 x 2-1/2" wood screws (E) as shown.
Optional: Rotate wall arm 180° to position the arm closer to the ceiling.
K
E
Visit the Peerless Web Site at www.peerless-av.com
6 of 9
ISSUED: 03-23-09 SHEET #:055-9260-8 04-25-13
Installation to Solid Concrete or Cinder Block Wall for PSTK-028, PSTK-028-W
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete surface in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components.
Drill four 5/16" (8 mm) dia. holes to a minimum
1
depth of 2.5" (64 mm). Insert anchors (G) in holes fl ush with wall as shown. Attach wall plate (K) using four #14 x 2 -1/2" wood screws (E) as shown in Illustration A and 1, 2, and 3. Tighten all fasteners.
Optional: Rotate wall arm 180° to position the arm closer to the ceiling.
1
Drill holes and insert anchors (G).
2
K
concrete surface
G
WARNING
• Tighten wood screws fi rmly, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
• Concrete anchors are not intended for attachment to concrete wall covered with a layer of plaster, drywall, or other fi nishing material. If mounting to concrete wall covered with plaster/drywall is unavoidable (not evaluated by UL), plaster/drywall (up to 5/8" thick) must be counterbored as shown right. If plaster/ drywall is thicker than 5/8", custom fasteners must be supplied by installer (not evaluated by UL).
INCORRECT CORRECT
wall
plate
concrete
wall
plate
concrete
E
Place plate (K) over anchors (G) and secure with screws (E).
3
Tighten all fasteners.
SOLID CONCRETE
G
E
G
CINDER BLOCK
plaster/
CUTAWAY VIEW
Visit the Peerless Web Site at www.peerless-av.com
dry wall
plaster/ dry wall
7 of 9
K
Illustration A
ISSUED: 03-23-09 SHEET #:055-9260-8 04-25-13
Assembly of Adjustment Tube
Slide carriage (B) over wall arm (A) and adjust to the desired projector throw distance as shown. Lock carriage
2
(B) into place using four M5 x 10 mm screws (D).
B
A
D
Installing PRGS Projector Mount
Installing PRGS projector mount to wall arm assembly: Attach PRGS projector mount (J) to carriage (B) using
3
two 1/4-20 phillips screws (H) and two at washers (I) as shown below.
B
J
I
Visit the Peerless Web Site at www.peerless-av.com
8 of 9
H
ISSUED: 03-23-09 SHEET #:055-9260-8 04-25-13
Routing Cables
Routing Cables through PRGS projector mount and wall arm assembly: Guide projector cables into
4
openings in projector mount and wall arm assembly as shown below. Insert Tube Cap (F) into end of wall arm (A). Note: Cables must be removed from projector before routing through wall arm. Note: Follow projector mount (PRGS) instructions to install projector.
F
PROJECTOR CABLES
A
Visit the Peerless Web Site at www.peerless-av.com
9 of 9
All other brand and product names are trademarks or registered trademarks of their respective owners.
ISSUED: 03-23-09 SHEET #:055-9260-8 04-25-13
© 2013, Peerless Industries, Inc. All rights reserved.
Peerless Industries, Inc.
2300 White Oak Circle
Aurora, Il 60502
www.peerless-av.com
Loading...