Installation and Assembly:
Tray Style Projector Mount
Models: PSM-UNV, PSM-UNV-S, PSM-UNV-W
Visit the Peerless Web Site at www.peerlessmounts.com
1 of 9
This product is UL Listed. It must be
R
installed by a qualifi ed professional
installer.
Maximum UL Load Capacity:
50 lb (22.7 kg)
ISSUED: 08-09-06 SHEET #: 055-9469-3 06-15-10
For customer care call 1-800-729-0307 or 708-865-8870.
NOTE: Read entire instruction sheet before you start installation and assembly.
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, please call
Peerless customer service at 1-800-729-0307.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Never exceed the Maximum UL Load Capacity. See page 1.
• If mounting to wood ceiling joists, make sure that mounting screws are anchored into the center of the joists. Use of
an "edge to edge" stud fi nder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal
injury.
• Unistrut or Structural Ceiling Plates (CMJ 300, CMJ 310)*
• Anti-Vibration Ceiling Plates (ACC 845)*
• I-Beam Clamps (ACC 558, ACC 559)
• Truss Ceiling Adapter (ACC 557)*
• Unistrut Adapter (ACC 550)
• Escutcheon Ring (ACC 640)*
• Round Ceiling Plate (ACC 570)
• Cord Wrap (ACC 852, ACC 852W, ACC 852S)*
• 3/4" Pipe Reducer (ACC 913)*
• Fixed Length 1 1/2" Extension Columns
(EXT models)
• Adjustable Length 1 1/2" Extension Columns
(ADJ models)
• Extension Column Stabilizer Kit (ACC 050)*
• Extension Column Connector (ACC 109)
• 1/2" Threaded Rod (ACC 820)*
• Threaded Rod Adapter (ACC 810)*
*Not UL Listed
Tools Needed for Assembly
• stud fi nder ("edge to edge" stud fi nder is recommended)
• standard andphillips screwdrivers
• drill with 1/4", 3/8", and 5/32" drill bits
IMPORTANT! Turn to the appropriate page for your ceiling installation.
Installations:
To Wood Joist Finished Ceilings,
Exposed Wood Joists, or Wood Beam Ceilings .........................................................................................page 4
To Concrete Ceilings .....................................................................................................................................page 5
To Extension Column ....................................................................................................................................page 6
Projector Alignment:
Adjusting Roll Pitch and Yaw .......................................................................................................... step 8, page 9
ISSUED: 08-09-06 SHEET #: 055-9469-3 06-15-10
Visit the Peerless Web Site at www.peerlessmounts.com
2 of 9
For customer care call 1-800-729-0307 or 708-865-8870.
IMPORTANT! Read entire instruction sheet before you start installation and assembly.
A
V
Before you start check the parts list below to make sure all of the parts shown are included.
Parts List
DescriptionQty. Part #Part #Part #
tray assembly1055-0724055-0724-S055-0724-W
B cord management adapter1580-1025580-4025580-2025
C spacer12 540-9416540-9416540-9416
D bushing4590-1116590-1116590-1116
E square nut4530-1022530-1022530-1022
F washer4540-1025540-1025540-1025
G 1/4 x 3/8 socket pin screw4520-1109520-1109520-1109
H M3 x 16mm serrated washer head socket pin screw4510-1083510-1083510-1083
IM3 x 25mm serrated washer head socket pin screw4510-1127510-1127510-1127
J M4 x 16mm serrated washer head socket pin screw4510-1087510-1087510-1087
K M4 x 25mm serrated washer head socket pin screw4510-1082510-1082510-1082
L M4 x 35mm serrated washer head socket pin screw4510-1097510-1097510-1097
M M5 x 16mm serrated washer head socket pin screw4510-1161510-1161510-1161
N M5 x 25mm serrated washer head socket pin screw4510-1122510-1122510-1122
O M6 x 20mm serrated washer head socket pin screw4 510-9554510-9554510-9554
P M6 x 30mm serrated washer head socket pin screw4510-1067510-1067510-1067
Q 2 mm allen wrench1560-1097560-1097560-1097
R 4 mm allen wrench1560-9646560-9646560-9646
S lock plug13022-5023022-5023022-502
T thumb screw1560-0106560-0106560-0106
U wood screw25S1-015-C03 5S1-015-C04 5S1-015-C04
alligator anchor2590-0097590-0097590-0097
W M5 x 10mm socket pin screw1520-1164520-2031520-2031
X 10-32 x 3/16 slotted set screw3520-1187520-2187520-2187
Y ceiling plate1580-1042580-4042580-4042
Z key10000-3220000-3220000-322
PSM-UNVPSM-UNV-S PSM-UNV-W
A
B
J
K
L
M
T
S
NOTE: Assembled to
tray assembly (B)
NOTE: Actual parts may appear slightly different than illustrated.
Visit the Peerless Web Site at www.peerlessmounts.com
N
U
C
O
3 of 9
P
D
V
E
F
G
H
I
Q
R
Y
W
For customer care call 1-800-729-0307 or 708-865-8870.
X
ISSUED: 08-09-06 SHEET #: 055-9469-3 06-15-10
Z
Installation To Wood Joist Finished Ceilings,
Exposed Wood Joists, or Wood Beam Ceilings
Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (Y) with two #14 x 2.5"
1
(6 mm x 65 mm) wood screws (U) as shown using 3/8" (10 mm) socket wrench.
Skip to step 2
WARNING
• Tighten wood screws so that ceiling plate is fi rmly
attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.
• Never tighten in excess of 80 in • lb (9 N.M.).
• Make sure that mounting screws are anchored into
the center of the studs. The use of an "edge to edge"
stud fi nder is highly recommended.
WOOD JOIST
CEILING
Y
WARNING
• It is the responsibility of the installer to verify that the
supporting surface will safely support the combined
load of all attached hardware and components.
U
U
Visit the Peerless Web Site at www.peerlessmounts.com
4 of 9
ISSUED: 08-09-06 SHEET #: 055-9469-3 06-15-10
For customer care call 1-800-729-0307 or 708-865-8870.
WARNING
• When installing Peerless wall mounts on concrete, verify that you have a minimum of 1 5/8" of actual concrete
surface in the 1/4" diameter hole to be used for the concrete anchors. Do not drill into mortar joints! Concrete must
meet ASTM C-90 specifi cations.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Never exceed the Maximum UL Load Capacity.
Installation to Concrete Ceilings
Drill two 1/4" (6 mm) dia. holes to a minimum
1
depth of 2.5" (64 mm). Attach ceiling plate (Y)
using two concrete anchors (V) and #14 x 2.5"
wood screws (U) as shown in Illustration A and
1, 2, and 3 (below). Tighten all fasteners.
Skip to step 2
V
CONCRETE CEILING
WARNING
• Tighten wood screws so that ceiling plate is fi rmly
attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other fi nishing
material. If mounting to concrete surfaces covered
with a fi nishing surface is unavoidable (not evaluated
by UL), the fi nishing surface must be counterbored
as shown below. If plaster/drywall is thicker than
5/8", custom fasteners must be supplied by installer
(not evaluated by UL).
INCORRECT
concrete
Y
CORRECT
Y
concrete
Y
U
Illustration A
1
concrete
surface
V
Drill holes and insert anchors (V).
2
Place plate (Y) over anchors (V) and secure with screws (U).
3
U
Y
V
plaster/
dry wall
CUTAWAY VIEW
Visit the Peerless Web Site at www.peerlessmounts.com
plaster/
dry wall
5 of 9
U
Tighten all fasteners.
ISSUED: 08-09-06 SHEET #: 055-9469-3 06-15-10
For customer care call 1-800-729-0307 or 708-865-8870.
Top Tray Installation
Remove the lock plug (S) by using key to unscrew it from the assembly as shown in detail 2.1. Open the mount
and remove thumb screw as shown in detail 2.2.
2
NOTE: The upper tray of the mount will now slide off of the lower tray.
S
For Extension Column Installation, skip to step 3A
Thread tilting mechanism of top tray into ceiling plate (Y). Align the notch with one of the four holes of the ceil-
3
ing plate (Y) and secure tilting mechanism with a M5 x 10 mm socket pin screw (W) using 4mm security allen
wrench (R) as shown in detail 3.
NOTE: Slotted set screw (X) is used to jam against the threads of the tilting mechanism to prevent any excess
movement of the upper tray. Do not overtighten screw; overtightening screw will damage threads making it diffi cult to separate the products.
IMPORTANT! Be sure not to touch the projector while tightening the set screw on the tilting mechanism. This
may cause the image to be unaligned when you let go.
WOOD JOIST
CEILING
DETAIL 2.1
Y
THUMB SCREW
DETAIL 2.2
Y
W
NOTCH
X
UPPER TRAY
Visit the Peerless Web Site at www.peerlessmounts.com
TILTING
MECHANISM
6 of 9
TILTING
MECHANISM
DETAIL 3
ISSUED: 08-09-06 SHEET #: 055-9469-3 06-15-10
For customer care call 1-800-729-0307 or 708-865-8870.
Extension Column Installation (Sold Separately)
Thread tray assembly (A) into cord management (B) to extension column (sold separately) as shown.
3A
NOTE: Slotted set screw (X) is used to jam against threads of extension column to prevent any excess
movement of projector mount assembly (A).
Skip to step 4
1 1/2" EXTENSION COLUMN
(SOLD SEPARATELY)
UL LISTED EXT OR ADJ
SERIES)
WARNING
• Do not overtighten! Overtightening may cause
permanent damage to the projector. Torque to
26-35 in • lb (30-40 kg • cm).
A
B
Installation of Projector
Flip projector upside down. Attach lower tray to
4
the bottom of the projector using appropriate
number of screws (H,I,J,K,L,M,N,O,P),
washers (F) and spacers (C) as shown. Use
4 mm allen wrench (R) to tighten
screws (H,I,J,K,L,M,N,O,P).
Important: If projector does not have at least
three mounting holes, do not use this adapter
plate.
NOTE: Some projectors have feet which can be
removed and the corresponding threaded insert
can be used for a mounting hole.
NOTE: Projector may differ slightly in appearance.
WARNING
• Do not overtighten! Overtightening may cause
permanent damage to the projector. Torque to
26-35 in • lb (30-40 kg • cm).
SCREW
F
C
LOWER TRAY
Visit the Peerless Web Site at www.peerlessmounts.com
7 of 9
PROJECTOR
ISSUED: 08-09-06 SHEET #: 055-9469-3 06-15-10
For customer care call 1-800-729-0307 or 708-865-8870.
5
Slide upper tray into the lower tray as shown.
UPPER TRAY
LOWER TRAY
WARNING
• Do not lift more weight than you can handle! Use additional man power or mechanical lifting equipment to
safely handle placement of the projector!
Attach thumb screw to mount as shown to lock
6
the upper tray to the lower tray.
LOWER TRAY
UPPER TRAY
Visit the Peerless Web Site at www.peerlessmounts.com
8 of 9
THUMB SCREW
ISSUED: 08-09-06 SHEET #: 055-9469-3 06-15-10
For customer care call 1-800-729-0307 or 708-865-8870.
7
Close the mount and insert the lock plug (S) and key (Z) as shown.
NOTE: To remove key, slot must be in the horizontal position. This may require that you back off 1/4 turn.
IMPORTANT: Key is necessary for projector removal. Store it in a safe place.
Z
S
8
To adjust roll, pitch, and yaw loosen the set screw (shown below) using security allen wrench (R) or standard 4
mm allen wrench. You should be able to just slightly loosen the screw so that your adjustments can be set without having to hold the projector. Move projector to desired position and slowly tighten set screw.
NOTE: Be sure not to touch the projector while tightening the set screw. This may cause the image to be
unaligned when you let go.
IMPORTANT: Allen wrench (R) is your key for projector removal. Store it in a safe place.
SET SCREW
Visit the Peerless Web Site at www.peerlessmounts.com
9 of 9
For customer care call 1-800-729-0307 or 708-865-8870.
All other brand and product names are trademarks or registered trademarks of their respective owners.