Peerless Industries PRS-UNV-S, PRS-UNV, PRS-UNV-W, PRS-UNVP-S, PRS-UNVP User Manual

...
Installation and Assembly Manual:
PRS, RTR Series Projector Mount
Models: PRS-UNV, PRS-UNV-S, PRS-UNV-W
PRS-UNVP, PRS-UNVP-S, PRS-UNVP-W RTR-UNB, RTR-UNS, RTR-UNW
This product is intended for use with UL
R
Listed products and must be installed by a qualified professional installer.
Maximum UL Load Capacity:
25 lb (11.34 kg)
1 of 12
3215 W. North Ave. • Melrose Park, IL 60160 • (800) 865-2112 or (708) 865-8870 • Fax: (708) 865-2941 • www.peerlessmounts.com
Visit the Peerless Web Site at www.peerlessmounts.com
For customer care call 1-800-729-0307 or 708-865-8870.
ISSUED: 09-19-05 SHEET #: 055-9441-5 10-31-08
Note: Read entire instruction sheet before you start installation and assembly .
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, please call Peerless customer care at 1-800-865-21 12.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard­ware and components.
• Never exceed the Maximum Load Capacity . See page 1.
• If mounting to wood ceiling studs, make sure that mounting screws are anchored into the center of the studs. Use of an "edge to edge" stud finder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws firmly , but do not overtighten. Overtightening can damage the items, greatly reducing their holding power.
• This product is intended for indoor use only. Use of this product out doors could lead to product failure and personal injury.
• This product was designed and intended to be mounted to the following supporting surfaces checked below with the hardware included in this product as specified in the installation sheet. To mount this product to an alternative support­ing surface, contact Peerless customer care at 1 800 865-21 12.
• This product was designed to be installed on the following ceiling construction only;
CEILING CONSTRUCTION ADDITIONAL HARDW ARE REQUIRED x Wood Stud None
x Wood Beam None x Solid Concrete None
Cinder Block Contact Customer Service Metal Stud Contact Customer Service Brick Contact Customer Service Other or unsure? Contact Customer Service
Tools Needed for Assembly
stud finder ("edge to edge" stud finder is recommended)
phillips screwdriver
drill
1/4" bit for concrete surface
5/32" bit for wood studs
level
Table of Contents
Parts List.......................................................................................................................................................................... 3
Installation to Extension Columns / Ceiling Plate.............................................................................................................. 4
Installation to Wood Joist Ceilings .................................................................................................................................... 5
Installation to Concrete Ceilings........................................................................................................................................ 6
Installation to Threaded Rods............................................................................................................................................ 7
Attaching Adapter Plate to Projector................................................................................................................................. 8
Projector Alignment ........................................................................................................................................................ 10
Accessories.............................................................................................................................................................. 11, 12
ISSUED: 09-19-05 SHEET #: 055-9441-5 10-31-08
Visit the Peerless Web Site at www.peerlessmounts.com
2 of 12
For customer care call 1-800-729-0307 or 708-865-8870.
PRS-UNV, PRS-UNVP RTR-UNB Part #
PRS-UNV-W, PRS-UNVP-W RTR-UNW Part #
Before you start check the parts list to insure all of the parts shown are included.
PRS-UNV-S,
Parts List
Description Qty.
A projector mount assembly (non-security adjustments) 1 055-0607 055-0608 055-0609
projector mount assembly (security adjustments) 1 055-0604 055-0605 055-0606
B adapter plate 1 055-1879 055-4879 055-2879 C #14 x 2.5 phillips hex head wood screw 2 5S1-015-C03 5S1-015-C04 5S1-015-C04 D concrete anchor 2 590-0097 590-0097 590-0097 E #10-32 x 1/4" socket pin screw 1 520-1196 520-2196 520-2196 F 1/4" flat washer 2 540-1078 540-1078 540-1078 G M3 x 8 mm socket pin serrated washer head screw 4 510-1004 510-2004 510-2004 H M4 x 10 mm socket pin serrated washer head screw 4 510-1060 510-2060 510-2060 I M5 x 10 mm socket pin serrated washer head screw 4 510-1126 510-2063 510-2063 J M6 x 10 mm socket pin serrated washer head screw 4 510-1066 510-2066 510-2066 K #6 flat washer 4 540-1025 540-2025 540-2025 L 4 mm security t-wrench 1 560-1718 560-1718 560-1718 M 2 mm security allen wrench 1 560-1097 560-1097 560-1097
Non-Security adjustments
A
Models:PRS-UNVP , PRS-UNVP-S, PRS-UNVP-W,
RTR-UNB, RTR-UNS, RTR-UNW
PRS-UNVP-S RTR-UNS Part #
PHILLIPS ADJUSTMENT SCREWS
Security adjustments
A
Models: PRS-UNV , PRS-UNV-S, PRS-UNV -W
SOCKET PIN ADJUSTMENT SCREWS
HGI
J
Note: Actual parts may appear slightly different than illustrated.
K
D
C
L
B
E
F
M
Visit the Peerless Web Site at www.peerlessmounts.com
3 of 12
ISSUED: 09-19-05 SHEET #: 055-9441-5 10-31-08
For customer care call 1-800-729-0307 or 708-865-8870.
Installation to Extension Column / Ceiling Plate
1
NOTE: Refer to accompanying instructions with ceiling plates (sold separately) for installing these models to ceiling.
Screw projector mount assembly (A) onto extension column as shown in figure 1.1. NOTE: For 3/4" extension columns, reducer ACC 913 will be required as shown in figure 1.2. Tighten swivel stop screw against extension column, flush mount tube or reducer using 4 mm security t-wrench (L) as shown in figure
1.3. NOTE: Swivel stop screw is used to jam against threads of extension column, flush mount tube or reducer to
prevent any excess movement of projector mount assembly (A). Do not overtighten screw; overtightening screw will damage threads making it difficult to separate products.
Skip to step 5.
1 1/2" EXTENSION COLUMN (SOLD SEPARA TEL Y) UL LISTED EXT OR ADJ SERIES)
A
BACK OF MOUNT
A
fig. 1.1 fig. 1.2
3/4" EXTENSION COLUMN (SOLD SEPARA TEL Y)
ACC 913 (NOT UL LISTED) (SOLD SEPARA TEL Y)
BACK OF MOUNT
Visit the Peerless Web Site at www.peerlessmounts.com
fig. 1.3
4 of 12
CMJ 455 (SOLD SEPARA TEL Y)
SWIVEL STOP SCREW
ISSUED: 09-19-05 SHEET #: 055-9441-5 10-31-08
For customer care call 1-800-729-0307 or 708-865-8870.
Loading...