Visit the Peerless Web Site at www.peerlessmounts.com
ISSUED: 09-24-10 SHEET #: 125-9146-2 (6-25-13)
Page 2
Installation to Wall Stud
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is rmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud nder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations.
Use a stud nder to locate the edges of the stud. Use of an edge-to-edge stud nder is highly recommended.
1
Based on their edges, draw a vertical line down the stud center. Place wall plate (A) on wall as a template.
Level plate, and mark the center of the six mounting holes. Make sure that the mounting holes are on the stud
centerline. Drill six 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Make sure that the wall plate (A) is level,
secure it using six #14 x 2.5" wood screws (E) as shown below.
E
Stud
A
2 of 5
Visit the Peerless Web Site at www.peerlessmounts.com
ISSUED: 09-24-10 SHEET #: 125-9146-2 (6-25-13)
Page 3
Installation to Solid Concrete or Cinder Block
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
Make sure that wall plate (A) is level, use it as a
1
template to mark six mounting holes. Drill six 5/16”
(8mm) dia. holes to a minimum depth of 2.5” (64
mm). Insert anchors (F) in holes ush with wall as
shown (right). Place wall plate (A) over anchors and
secure with six #14 x 2.5” screws (E) as shown.
Level, then tighten all fasteners.
WARNING
• Tighten screws so that wall plate is rmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
nishing material. If mounting to concrete surfaces
covered with a nishing surface is unavoidable,
the nishing surface must be counter bored as
shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws. If
plaster/drywall is thicker than 5/8" (16 mm), custom
fasteners must be supplied by installer
solid concrete
F
E
A
1
Drill holes and insert anchors (F).
2
A
E
Place plate (A) over anchors (E) and secure with screws (F).
cinder block
concrete
surface
F
F
INCORRECTCORRECT
wall
plate
plaster/
CUTAWAY VIEW
Visit the Peerless Web Site at www.peerlessmounts.com
dry wall
concrete
wall
plate
plaster/
dry wall
concrete
3 of 5
3
Tighten all fasteners.
ISSUED: 09-24-10 SHEET #: 125-9146-2 (6-25-13)
Page 4
Attach adapter brackets (C) to display using four M6 x 12 mm phillips screw (I) with nylon shoulder washers (H), or
2
using four M8 x 15 mm phillips screws (J).
I or J
H
C
DISPLAY
Attaching Adapter Brackets to Wall Plate
Hook adapter brackets (C) to wall plate (A). Slide adapter brackets (C) to position.
3
Once display is located in desired position, secure with lock bracket (B) using two M5 x 10 mm socket pin Type F
screws (D) to lock in place as shown in gure 3.2.
DISPLAY
C
Figure. 3.1Figure. 3.1
BACK FOR WALL PLATE
SUPPORTING SURFACE
NOT SHOWN FOR CLARITY
A
B
A
D
4 of 5
Visit the Peerless Web Site at www.peerlessmounts.com
All other brand and product names are trademarks or registered trademarks of their respective owners.
Optional for Multiple Displays: Installing Spacer Kit (Sold Separately)
Slide spacers into tab of mounted wall plate as shown. Keeping spacers ush against wall plate, fasten two
#10 x 3/4" wood screws as shown. There must be two spacers placed on the same side as the additional
4
wall plate. Align the tabs of the additional wall plate ush with the spacers. Follow main instruction for proper
installation of additional wall plates.
NOTE: SUPPORTING SURFACE NOT SHOWN FOR CLARITY
WALL PLATE ASSEMBLIES MAY BE DIFFERENT
THAN ILLUSTRATED
DIAMOND CUT
VERTICAL
ORIENTATION
ROUND CUT
HORIZONTAL
ORIENTATION
NOTE: ADDITIONAL WALL PLATES SOLD SEPARATELY
DIAMOND CUT
MOUNTED
WALL PLATE
ROUND CUT
ADDITIONAL
WALL PLATE
MOUNTED
WALL PLATE
ADDITIONAL
WALL PLATE
5 of 5
Visit the Peerless Web Site at www.peerlessmounts.com
ISSUED: 09-24-10 SHEET #: 125-9146-2 (6-25-13)