Peerless-AV DCS400 Installation

Installation and Assembly - Truss Ceiling Decoupler Adapter
Model: DCT 100
WARNING
• Installer must verify that the ceiling truss will safely support four times the combined weight of all attached equipment and hardware.
Parts List
PART # QTY. DESCRIPTION
A ceiling decoupler assembly 1 128-0418 B U-bolt 2 520-9241 C washer 4 540-9407 D lock washer 4 540-9424 E 3/8-16" hex bolt 4 530-9308 F M5 x 10 mm phillips screw 1 520-9250
Some parts may appear slightly different than illustrated.
Tools Required
Before you start make sure all parts listed are included with your product.
AB
C
D
This product must be
R
COMBINED BALANCED LOAD CAPACITY :
E
installed by a qualified, professional installer.
300 lb (136 kg)*
F
The following tools are required for assem­bly and installation, but are not included:
• 9/16" wrench
• Philips screwdriver
Select the location on the truss for positioning the decoupler assembly (A) and position the U­bolts (B) over the top as shown. Then attach the decoupler assembly (A) from below with the hex bolts (E), lock washers (D) and washers (C) as shown. Tighten bolts to hold decoupler assembly (A) to U-Bolts (B) but leave loose enough to allow for minor adjustment to the angle of the column.
Note: The orientation of the decoupler
assembly (A) relative to the truss will depend upon the shape of the truss; see Detail 1 at right.
Detail 1
3" dia.
max.
B
A
C D E
The orientation of the decoupler assembly will depend on the shape of the truss
3" x 3"
max.
*Includes total weight of the components and hardware.
For round pipes.
1 of 2
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
For rectangular, square
or I-Beam trusses.
ISSUED: 04-24-00 SHEET #: 142-9002-4 04-21-05
Note: Insert the M5 x 10 mm screw (F) into the threaded pipe fitting as directed in the extension column instructions. If you are using an extension pipe without a notch, drill a 11/64" diameter through the pipe and insert the screw through the decoupler assembly (A) into the pipe; see Detail 2.
Attach the adjustable extention column according to the instructions provided with it. Use a level to make sure the column is plumb and make adjustments as necessary.
Tighten the hex bolts (E) to a maximum of 25 lbf·ft (34 N·m) so that the lock washers (D) become flat. Mount your bracket
according to the instructions provided with it.
Detail 2
F
E
D
A
2 of 2
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
ISSUED: 04-24-00 SHEET #: 142-9002-4 04-21-05
Loading...