![](/html/28/2863/286375f85824db3669f83c8a845217e4b4bb26ff977f6b9c08b6b83a1076bf4d/bg1.png)
ASSEMBLY INSTRUCTIONS
Structural Ceiling Decoupler Adapter PATENT PENDING
Before beginning assembly...
Please read entire instruction sheet and check the parts list to ensure that all components have been included.
Recommended tools...
Drill and 5/16" masonry drill bit, 7/16" torque wrench, hammer
This product is intended for use with UL Listed
R
products and must be installed by a qualified
professional installer.
MODELS
DCS 200
DCS 400
DCS 200
Lok/bolt
*COMBINED LOAD CAPACITY: 300 lbs.
*Total weight of components and hardware
Threaded
Fitting
WARNING
• Installer must verify that the wall will safely support
four times the combined weight of all attached equipment and hardware.
INSTALLATIONand componentry.
1. Use the ceiling plate as a guide to mark and drill
twelve 5/16" dia. holes to a depth of no less than 1 3/8".
2. After holes are drilled, align the ceiling plate with
the holes and hammer in the twelve Lok/BoltsTM.
ALL FASTENERS MUST BE USED.
3. Be sure that the ceiling plate is snug to the ceiling.
4. Tighten each Lok/Bolt to 8 ft. lbs. (11 NM) torque.
5. DCS 200 ONLY
The #10-32 x 1/2" phillips screw has been provided to lock
the Peerless extension column into place after insertion (see
instructions provided with column).
DCS 400
5
#10 x 1/2"
phillips screw
Extension
Column (sold
separately)
LOK/BOLT INSTALLATION - SIDE VIEW
ceiling
Structural
Ceiling
Plate
*COMBINED LOAD CAPACITY: 1200 lbs.
Lok/bolt
7/16" Torque
Wrench
WARNING
• If you are using an extension pipe without a notch, drill
a 1 1/64 (0.172") dia. hole through the pipe and insert
the screw through the threaded fitting and pipe. Failure
to do so could cause the assembly to fail.
For proper attachment of threaded extension pipe to DCS 200
see instruction sheet provided with extension pipe.
For proper attachment of Adjustable Multi-Display Extension Unit
to DCS 400 see instruction sheet provided with extension unit.
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
© 2005 Peerless Industries, Inc. All rights reserved.
Peerless is a trademark of Peerless Industries, Inc.
2
PARTS LIST FOR DCS 200
PART NO. QTY. DESCRIPTION
128-0419 1 STRUCTURAL CEILING DECOUPLER ADAPTER
560-9707 12 RAWLTM 5005 LOK/BOLT
520-9560 1 #10-32 x 1/2" PHILLIPS SCREW
PARTS LIST FOR DCS 400
PART NO. QTY. DESCRIPTION
128-0421 1 STRUCTURAL CEILING DECOUPLER ADAPTER
560-9707 12 RAWLTM 5005 LOK/BOLT
1 of 1
34
ISSUED: 07-15-94 SHEET #: 142-9001-4 04-20-05