Installation and Assembly - Ceiling Plate for Jumbo Mounts
Note: Read entire instruction sheet before
beginning installation and assembly.
R
This product is intended for use with UL
Listed products and must be installed by a
qualified professional installer.
Models: CMJ 470
CMJ 480 CMJ 490
IMPORT ANT! Certain ceilings require additional mounting hardware...
CEILING CONSTRUCTION ADDITIONAL HARDWARE REQUIRED
Wood Joist, Wood Beam none
Concrete Concrete Anchor Kit - order accessory kit ACC 244.
Other or unsure? Call Peerless Customer Care.
For customer care, or to order
accessory kits call
1-800-7865-2112
Max. Load Capacity:
300 lb (137 kg)
Note: This ceiling plate is intended for use only to support Jumbo Mount TV Brackets or other products as specified by Peerless
Industries, Inc. Combine only as specified (see specifications on page 2). Fasteners provided are for attachment to wood structural members (joists or beam). Order additional fastener kit ACC 244 if attaching to a solid concrete ceiling. This product is
intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury.
From the top thread the Flush Mount Tube (included
with your Jumbo Mount Bracket) through the
threaded fitting in the ceiling plate.
Note: If you will install an extension column DO NOT
INSTALL THE FLUSH MOUNT TUBE. Begin with step 2.
flush mount tube
(included with Jumbo
Mount Bracket)
ceiling
plate
Installation Wood Joist Finished Ceiling,
Exposed Wood Joists, or Wood Beam Ceiling.
(See 3 for concrete ceilings). Drill four 5/32" (4 mm)
dia. holes to a minimum depth of 2.5" (64 mm).
Attach with four #14 x 2.5" (6 mm x 65 mm) wood
screws as shown using 3/8" (10 mm) socket
wrench. Tighten wood screws so ceiling plate is
firmly attached.
WARNING
end
cap
PARTS LIST
PART # QTY. DESCRIPTION
128-1039 1 ceiling plate (CMJ 470 only)
128-1086 1 ceiling plate (CMJ 480 only)
128-1087 1 ceiling plate (CMJ 490 only)
5S1-015-C03 4 #14 x 2.5" (6 mm x 65 mm) wood screw
2PT-22CA01D 2 end cap
520-9250 1 M5 x .8 x 10 mm phillips screw (for use
with extension column if applicable)
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112.
• Tighten wood screws so that ceiling plate is firmly
attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the
center of the joists. The use of an "edge to edge" stud
finder is highly recommended.
1 of 2
ISSUED: 05-22-00 SHEET #: 128-9002-7 06-22-12
WARNING
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor .
• Installer must verify that the supporting surface will safely support the combined weight of all attached equipment and
hardware.
For Concrete Ceilings drill four 3/8" (10 mm) dia.
holes to a minimum depth of 3" (76mm).
Attach using concrete expansion anchors as shown
(right). Tighten to 80 in • lb (9 N.M.) maximum
torque.
Snap end caps into place.
WARNING
• Tighten wood screws firmly , but do not overtighten.
Overtightening can damage the bolts, greatly reducing
their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
• Concrete anchors are not intended for attachment to
concrete ceiling covered with a layer of plaster,
drywall, or other finishing material. If mounting to
concrete ceiling covered with plaster/drywall is
unavoidable, plaster/drywall (up to 5/8" thick) must be
counterbored. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer .
1
Drill holes and insert anchors.
2
Place ceiling plate over anchors and secure with screws.
ceiling
plate
concrete
surface
anchor
anchor
3
Tighten all fasteners.
CUT AW A Y VIEW
end cap
CEILING PLATE FOR JUMBO MOUNTS - SPECIFICATIONS
Model
Numbers
CMJ 470
CMJ 480
CMJ 490
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112.
© 2005 Peerless Industries, Inc. All rights reserved.
Peerless is a registered trademark of Peerless Industries, Inc.
All other brand and product names are trademarks or registered trademarks of their respective owners.
Max. Load Capacity
Concrete
(136.1 kg) (136.1 kg)
Wood
300 lb300 lb
Compatible Jumbo
Mount Models
JM 2630, JM 2640, JM
2640D, JM 2650, JM
2650D, JM 2655, JM 2660,
JM 2665, JM 2670,
JM 2675
• Weight of TV or Screen not to exceed maximum load
capacity.
2 of 2
WARNING
ISSUED: 05-22-00 SHEET #: 128-9002-7 06-22-12