![](/html/44/4428/44281a6642893fcaa0e0bd5cc0f78b74697da0625f7d4866330ce8434e184a91/bg1.png)
Installation and Assembly - OSHPD Ceiling Plate for
Jumbo 2000
®
Mounts
Models: CMJ 471,
CMJ 471W
IMPORTANT! Read entire instruction sheet
before beginning installation and assembly.
This product is intended for use with UL
R
PARTS LIST
BLACK WHITE
PART # PART # QTY. DESCRIPTION
A 128-1270 128-2270 1 tapered ceiling bracket
B 2PT-22CA01D 2PT-22CA01F 2 end cap
C 520-1117 520-1117 4 A325 grade 3/8" - 16 x 2.5" nut & bolt
D 540-9407 540-9407 4 .406 x .812 x .060 washer
E 520-9250 520-9250 1 M5 x .8 x 10 mm phillips screw (for use
Note: Actual parts may appear slightly different than illustrated.
IMPORTANT: If using different bolts, the bolts must be A325 grade.
This Ceiling Plate is intended for use only to support Jumbo 2000 Mount TV
Brackets or other products as specified by Peerless Ind, Inc. Fasteners provided
are for attachment to a steel structure as specified by OSHPD.
Listed products and must be installed
by a qualified professional installer.
with extension column if applicable)
From the top, thread the Flush Mount Tube
(included with your Jumbo Mount Bracket) through
the threaded fitting in the ceiling plate (A).
• Installer must verify that the wall will safely support
four times the combined weight of all attached equipment and hardware.
flush mount tube
(included with Jumbo
WARNING
A
E
Mount Bracket)
C
B
D
MAXIMUM LOAD
CAP ACITY :
300 lb (137 kg)
IMPORTANT: If you will install an
extension column DO NOT INSTALL
THE FLUSH MOUNT TUBE. Begin with
step 2.
Attach ceiling plate (A) to steel structure
with four 3/8" - 16 x 2.5" nuts & bolts (C)
and four .406 x .812 x .060 washers (D)
as shown using 9/16" (14 mm) socket
wrench. Tighten bolts so ceiling plate is
firmly attached. DO NOT TIGHTEN
WITH EXCESSIVE FORCE! Overtightening can cause stress damage to bolts
greatly reducing their holding power!
Snap end caps (B) into place.
B
C
C
generic steel
structure
A
A
D
1 of 2
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
ISSUED: 04-30-02 SHEET #: 128-9134-2 08-11-04
![](/html/44/4428/44281a6642893fcaa0e0bd5cc0f78b74697da0625f7d4866330ce8434e184a91/bg2.png)
When attaching the cross support to the extension
column, carefully thread retaining collar onto end of
the extension column. Tighten at least four complete
turns ending with one of the small threaded holes
aligned with slot in the end of the extension column.
Insert and tighten one M5 screw (E).
WARNING
cross support
• Set screw (E) is self tapping and may be hard to get
started but is essential to this installation. Failure to
install this screw can cause the mount to fall.
cross support
E
retaining
collar
(BOTTOM VIEW)
extension
column
2 of 2
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
© 2004 Peerless Industries, Inc. All rights reserved.
Peerless is a registered trademark of Peerless Industries, Inc.
All other brand and product names are trademarks or registered trademarks of their respective owners.
ISSUED: 04-30-02 SHEET #: 128-9134-2 08-11-04