Installation and Assembly - Ceiling Plate for
Jumbo Mounts
IMPORTANT! Read entire instruction sheet before beginning installation and assembly.
Models: CMJ 470W, CMJ 480W ,
CMJ 490W
IMPORT ANT! Certain ceilings require additional mounting hardware...
CEILING CONSTRUCTION ADDITIONAL HARDWARE REQUIRED
Wood Joist, Wood Beam none
Concrete Concrete Anchor Kit - order accessory kit ACC 204.
Other or unsure? Call Peerless Customer Service.
PARTS LIST
PART # QTY. DESCRIPTION
128-2039 1 ceiling plate (CMJ 470W only)
128-2086 1 ceiling plate (CMJ 480W only)
128-2087 1 ceiling plate (CMJ 490W only)
5S1-015-C03 4 #14 x 2.5" (6 mm x 65 mm) wood screw
2PT-22CA01F 2 end cap (white models only)
520-9250 1 M5 x .8 x 10 mm phillips screw (for use
with extension column if applicable)
This Ceiling Plate is intended for use only to support
Jumbo Mount TV Brackets or other products as
specified by Peerless Industries, Inc. Combine only
as specified (see specifications on page 2). Fasteners provided are for attachment to wood structural
members (joists or beam). Order additional fastener
kit ACC 204 if attaching to a solid concrete ceiling.
From the top thread the Flush Mount Tube
(included with your Jumbo Mount Bracket)
through the threaded fitting in the ceiling plate.
IMPORTANT: If you will install an extension
column DO NOT INSTALL THE FLUSH
MOUNT TUBE. Begin with step 2.
For Wood Joist Finished Ceiling, Exposed
Wood Joists, or Wood Beam Ceiling. (See
step 3 for concrete ceilings). Drill four 5/32" (4
mm) dia. holes to a minimum depth of 2.5" (64
mm). Attach with four #14 x 2.5" (6 mm x 65
mm) wood screws as shown using 3/8" (10
mm) socket wrench. Tighten wood screws so
ceiling plate is firmly attached.
• Installer must verify that the ceiling will safely support
four times the combined weight of all attached equipment and hardware.
This product is intended for use with UL
R
Listed products and must be installed by a
qualified professional installer.
MAXIMUM LOAD CAPACITY :
300 lb (137 kg)
flush mount tube
(included with Jumbo
Mount Bracket)
ceiling
plate
WARNING
WARNING
• Tighten wood screws so that ceiling plate is firmly
attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.
• Never tighten in excess of 80 in • lb (9 N.M.).
end
cap
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
• Make sure that mounting screws are anchored into the
center of the studs. The use of an "edge to edge" stud
finder is highly recommended.
1 of 2
ISSUED: 08-12-04 SHEET #: 128-9152-1
CONCRETE ANCHOR
INSTALLATION
Cross Section: Attachment
to a concrete ceiling.
concrete
ceiling
end cap
WARNING
• Installer must verify that the ceiling will safely support
four times the combined weight of all attached equipment and hardware.
For Concrete Ceilings drill four 1/4" (6 mm)
dia. holes to a minimum depth of 2.5" (64 mm).
Concrete must be 2000 psi density minimum.
Insert anchors in holes flush with ceiling as
shown (left). Place ceiling plate over anchors
and secure with #14 x 2.5" (6 mm x 65 mm)
wood screws. Tighten all fasteners.
WARNING
• Tighten wood screws firmly , but do not overtighten.
Overtightening can damage the screws greatly reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
STEP 1: Hammer
in concrete anchor.
CEILING PLATE FOR JUMBO MOUNTS - SPECIFICATIONS
Model
Numbers
CMJ 470W
CMJ 480W
CMJ 490W
Max. Load Capacity
Concrete
(137 kg) (137 kg)
ceiling
plate
STEP 2: Tighten to 80 in • lb (9 N.M.)
maximum torque to expand anchors.
Wood
300 lb300 lb
Compatible Jumbo Mount Models
JM 2630S, JM 2640S, JM 2640DS, JM 2650S, JM
2650DS, JM 2655S, JM 2660S, JM 2665S, JM
2670S, JM 2675S
• Weight of TV or monitor not to exceed maximum load
capacity.
WARNING
• Concrete anchors are not intended for attachment to
concrete ceiling covered with a layer of plaster,
drywall, or other finishing material. If mounting to
concrete ceiling covered with plaster/drywall is unavoidable, plaster/drywall (up to 5/8" thick) must be
counterbored. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer .
CUT AW A Y VIEW
2 of 2
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
© 2004 Peerless Industries, Inc. All rights reserved.
Peerless is a registered trademark of Peerless Industries, Inc.
All other brand and product names are trademarks or registered trademarks of their respective owners.
ISSUED: 08-12-04 SHEET #: 128-9152-1