Peerless-AV ACC908 Installation

Installation and Assembly -
Lightweight Cathedral Ceiling Plate for Projectors
Model: ACC 912
This product is intended for use with UL
R
Listed products and must be installed by a qualified professional installer.
WARNING
• Installer must verify that the ceiling will safely support four times the combined weight of all attached equip­ment and hardware.
Maximum Load Capacity:
75 lb (34 kg)
Visit the Peerless Web Site at www.peerlessindustries.com
1 of 5
ISSUED: 03-26-03 SHEET #: 055-9213-2 11-10-04
For customer service call 1-800-729-0307 or 708-865-8870.
Parts List
Description Qty. Pa rt #
upper ceiling bracket 1 055-1484
A
lower ceiling bracket 1 055-1486
B
1/4-20 x 5/8" carriage bolt 4 520-1175
C
1/4-20 nylock nut 4 530-9413
D
1/4" ID x 3/4" OD washer 4 540-9401
E
#14 x 2.5" hex head wood screw 2 5S1-015-C04
F
M5 x .8 x 10 mm phillips self-tapping screw 1 520-9250
G
C
AB
D
E
G
F
Visit the Peerless Web Site at www.peerlessindustries.com
2 of 5
ISSUED: 03-26-03 SHEET #: 055-9213-2 11-10-04
For customer service call 1-800-729-0307 or 708-865-8870.
Flush Mount Tube Application (EXT 002 required)
Note: Skip this step if you are installing an extension column.
Insert flush mount tube from the top, and thread flush mount tube into threaded fitting of lower ceiling bracket (B).
B
THREADED
FITTING
Installation to Wood Joist Finished Ceiling,
Installation to Wood Joist Finished Ceiling, Exposed Wood Joists, or Wood Beam Ceiling
Exposed Wood Joists, or Wood Beam Ceiling
Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach upper ceiling bracket (A) with two #14 x 2.5" (6 mm x 65 mm) wood screws (F).
FLUSH MOUNT TUBE (EXT 002)
F
WARNING
• Tighten wood screws so that ceiling plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the joist. The use of an "edge to edge" stud finder is highly recommended.
CEILING
A
WALL
Visit the Peerless Web Site at www.peerlessindustries.com
3 of 5
ISSUED: 03-26-03 SHEET #: 055-9213-2 11-10-04
For customer service call 1-800-729-0307 or 708-865-8870.
Installation to Concrete Ceiling
Drill two 5/16" (8 mm) dia. holes to a minimum depth of 1-3/4" (45 mm). Attach upper ceiling bracket (A) using concrete expansion anchors (ACC 200) as shown. Tighten to 80 in. • lb (9 N.M.) maximum torque.
WARNING
• Tighten concrete anchor bolts firmly, but do not overtighten. Overtightening can damage the bolts, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
• Always attach concrete expansion anchors directly to load-bearing concrete.
• Never attach concrete expansion anchors to concrete covered with plaster, drywall or other finishing material.
A
CONCRETE ANCHOR
FOR PRODUCT SAFETY USE ONLY...
RAWL CONCRETE ANCHORS [.312 x
1.625 (8 mm x 41 mm)]. ORDER ACCESSORY FASTENER KIT #ACC 200
#5005 OR HILTI™ HL814
CEILING
WALL
CUTAWAY VIEW
Visit the Peerless Web Site at www.peerlessindustries.com
CONCRETE ANCHOR INSTALLATION
Cross Section: Attachment to a concrete ceiling.
A
STEP 1: Hammer
in concrete anchor.
4 of 5
STEP 2: Tighten to 80 in. • lb (9 N.M.)
maximum torque to expand anchors.
ISSUED: 03-26-03 SHEET #: 055-9213-2 11-10-04
For customer service call 1-800-729-0307 or 708-865-8870.
Attach upper ceiling bracket (A) to lower ceiling bracket (B) by inserting four carriage bolts (C) through holes of ceiling brackets (A & B). Fasten bolts (C) with four washers (E) and nylock nuts (D) as shown.
Note: Adjust lower ceiling bracket (B) until it is level before tightening nuts (D).
C
E
D
A
B
1-1/2" Extension Column Application (EXT or ADJ series)
Screw extension column into lower ceiling bracket (B) and align slot of extension column with one of the holes in lower ceiling bracket (B). Thread M5 x 10 mm self-tapping screw (G) through lower ceiling bracket (B) into extension column as shown in detail 1.
Note: 3/4" extension column (FLP series) can be used in place of the EXT or ADJ series. Two pipe reducers (ACC 913) are required for installing the 3/4" column.
G
SLOT
B
Visit the Peerless Web Site at www.peerlessindustries.com
©
2004 Peerless Industries, Inc. All rights reserved. Peerless is a registered trademark of Peerless Industries, Inc. All other brand and product names are trademarks or registered trademarks of their respective owners.
EXTENSION COLUMN
DETAIL 1
5 of 5
ISSUED: 03-26-03 SHEET #: 055-9213-2 11-10-04
For customer service call 1-800-729-0307 or 708-865-8870.