PERFORMANCE RANGE
• Flow rate up to 650 l/min (39 m³/h)
• Head up to 14 m
APPLICATION LIMITS
5 m maximum immersion depth
(with a suciently long power cable)
• Maximum liquid temperature +40 °C
• Passage of solids:
– up to Ø 40 mm for VX /35-N – up to Ø 50 mm for VX /50-N
• Minimum immersion depth for continuous service:
280 mm for VX /35-N – 300 mm for VX /50-N
CONSTRUCTION AND SAFETY STANDARDS
• Power cable length:
5 m for VX8-10/35-N, V X8-10/50 -N – 10 m for VX15/35 -N, V X15/50- N
• Float switch for single-phase versions
EN 6 0335-1 IE C 60335 -1 CE I 61-15 0
CERTIFICATIONS
Company with management system certied DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT
EN 6 003 4-1 IE C 60 034 -1 CEI 2-3
INSTALLATION AND USE
VX pumps are recommended for domestic, civil and industrial
applications in all cases where the water contains suspended solids up to Ø 50 mm, for example groundwater, surface water, lthy and dirty water. They are for example suitable for draining ooded areas such as cellars, underground car parks, car washes, for emptying cesspools and for sewage disposal. These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in xed installations.
PATENTS - TRADE MARKS - MODELS
Patent Pending n. BO2015A000116
OPTIONS AVAILABLE ON REQUEST
VX8-10 pumps with a 10 m power cable.
N.B.: Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications
• Single-phase pumps without oat switch
• Other voltages
GUARANTEE
2 years subject to terms and conditions
310 | GENERAL CATALOGUE 60 Hz
Page 2
CHARACTERISTIC CURVES AND PERFORMANCE DATA 60 Hz n= 3450 rpm
0 50 100 150
0 50 100
15
14
VX15/35-N
13
12
11
VX10/35-N
10
4
9
8
VX8/35-N
7
6
Head H (metres)
5
4
3
2
1
US g.p.m.
Imp g.p.m.
VORTEX
VX15/50-N
VX10/50-NVX8/50-N
feet
45
40
35
30
25
20
15
10
5
0
0 50 100 150 200 250 300 350 400 450 500 550 600 650
0 5 10 15 20 25 30 35 40
Flow rate Q
MODEL POWER (P)
Single-phase Three-phase kW HP
m³/ h
Q
l/min
VXm 8/35 -N VX 8/35 -N 0.55 0.75
VXm 10/35 -N VX 10/35 -N 0.75 1
VXm 15/35 -N VX 15/35 -N 1.1 1.5
H
metres
VXm 8/50 -N VX 8/50 -N 0.55 0.75
VXm 10/50 - N VX 10/50 -N 0.75 1
VXm 15/50 -N VX 15/50 -N 1.1 1.5
Q = Flow rate H = Total manometric head Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
0 3 6 12 18 21 24 27 30 33 36 39
0 50 100 200 300 350 400 450 500 550 600 650
9 8 7. 5 5.5 2.7 1
11 10 9.5 8 5.7 4 2
14 13.5 12. 8 11. 2 9 7. 7 6 4 2
6.5 6 5.8 5 4 3.3 2.5 1.5
9 8.5 8.2 7.5 6.5 5.8 5 3.8 2.5 1.5
11. 5 11 10.5 9.8 8.7 8 7.5 6.5 5.5 4.5 3.5 2
4
l/min
m³/h
0
0 1
GENERAL CATALOGUE 60 Hz | 311
Page 3
VX
VORTEX
POS. COMPONENT CONSTRUCTION CHARACTERISTICS
1 PUMP BODY Cast iron with an Epoxy Electro Coating treatment, with threaded port in compliance with ISO 228/1
2 BASE Stainless steel AISI 304
3 IMPELLER Stainless steel AISI 304 VORTEX type
4 MOTOR CASING Stainless steel AISI 304
5 MOTOR CASING PLATE Stainless steel AISI 304
6 MOTOR SHAFT Stainless steel EN 10088-3 - 1.4104
7 SHAFT WITH DOUBLE MECHANICAL SEAL SEPARATED BY AN OIL CHAMBER
Seal Shaft Position Materials
Model Diameter Stationary ring Rotational ring Elastomer
MG1-14 D SI C Ø 14 mm
Motor side Silicon carbide Graphite NBR Pump side Silicon carbide Silicon carbide NBR
8 BEARINGS 6203 ZZ / 6203 ZZ
9 CAPACITOR
Pump Capacitance
Single-phase
VXm 8/35-N VXm 8/50-N VXm 10/35-N VXm 10/50 -N
VXm 15/35-N VXm 15/50 -N
10 ELECTRIC MOTOR
VXm: single-phase 220 V - 60 Hz
with thermal overload protector incorporated into the winding
VX: three-phase 380 V - 60 Hz – Insulation: class F
– Protection: IP X8
POWER CABLE
11
“H07 RN-F” type (with Schuko plug for single-phase versions only)
Standard length 5 met
(220 V) (110 V or 127 V)
20 μF 450 VL 30 μF - 250 VL
25 μF 450 VL
res (10 metres for VX15/35-50)
11
9
8
4
10
5
7
6
8
12
12 FLOAT SWITCH
(only for single-phase versions)
312 | GENERAL CATALOGUE 60 Hz
1
2
3
Page 4
DIMENSIONS AND WEIGHT
Standard installation
a
h
b
MODEL PORT
Single-phase Three-phase DN a b c h h1 d e p
VXm 8/35 -N VX 8/35 -N
VXm 10/35 -N VX 10/35 -N 13.7 12. 6
VXm 15/ 35 -N VX 15/ 35 -N 421 15.7 14. 7
VXm 8/50 -N VX 8/50 -N
VXm 10/50 -N VX 10/50 -N 14.2 13.1
VXm 15/50 - N VX 15/50 - N 446 16.2 15.2
1½” Ø 40 mm
2” Ø 50 mm 155
c
DN
Passage of solids
h1
115 95
148
p (minimum)
DIMENSIONS mm kg
406
139 50
431
164 60
ed
(minimum)
variable 500 500
1~ 3~
12. 9 12. 6
13.4 13 .1
ABSORPTION
MODEL VO LTAGE
Single-phase 220 V 110 V 127 V
VXm 8/35 -N 3.8 A 7.6 A 7.0 A
VXm 10/35 -N 5.6 A 11. 5 A 10.4 A
VXm 15/ 35 -N 8.2 A
VXm 8/50 -N 3.8 A 7.6 A 7.0 A
VXm 10/50 -N 5.6 A 12.0 A 10.0 A
VXm 15/50 - N 7.7 A
MODEL VO LTAGE
Three-phase 220 V 380 V 440 V
VX 8/35 -N 3.2 A 1.8 A 1.6 A
VX 10/35 -N 4.1 A 2.4 A 2.0 A
VX 15/ 35 -N 6.3 A 3.6 A 3.1 A
VX 8/50 -N 3.2 A 1.8 A 1.6 A
VX 10/50 -N 4.0 A 2.3 A 2.0 A
VX 15/50 - N 6.3 A 3.6 A 3.1 A
PALLETIZATION
MODEL GROUPAGE CONTAINER
Single-phase Three-phase n. pumps n. pumps
VXm 8/35 -N VX 8/35 -N 60 80
VXm 10/35 -N VX 10/35 -N 60 80
VXm 15/35 -N VX 15/35 -N 54 72
VXm 8/50 -N VX 8/50 -N 54 72
VXm 10/50 -N VX 10/50 -N 54 72
VXm 15/50 -N VX 15/50 -N 54 72
GENERAL CATALOGUE 60 Hz | 313