Pedrollo SKRm2115V Specifications

SPRINKLER
Self-priming centrifugal pumps
Clean water
Domestic use
Civil use
PERFORMANCE RANGE
• Flow rate up to 400 l/min (24.0 m³/h)
• Head up to 36 m
APPLICATION LIMITS
• Manometric suction lift up to 9 m (HS)
• Liquid temperature between -10 ° C and +40 °C
• Ambient temperature up to +40 °C
• Max. working pressure 10 bar
• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS
EN 603 35 -1 IE C 60 335-1 CE I 61-15 0
CERTIFICATIONS
Company with management system certied DNV ISO 9001: QUALITY
EN 6003 4 -1 IE C 60 034 -1 CEI 2-3
INSTALLATION AND USE
Suitable for use with clean water and with liquids that are not chemically aggressive towards the materials from which the pump is made. The self-pri ming SPRINKLER pumps are designed to pump water even in cases where air is present. Because of their reliability and the fact that they are easy to use, they are recommended for use in domestic and civil applications such as the distribution of water in combination with pressure tanks, and for the irrigation of gardens and orchards, etc. The pump should be installed in an enclosed environment or sheltered from inclement weather.
OPTIONS AVAILABLE ON REQUEST
• Other voltages
• IPX5 protection
60 Hz | SPRINKLER
114 | GENERAL CATALOGUE 60 Hz
CHARACTERISTIC CURVES AND PERFORMANCE DATA 60 Hz n= 3450 min-1 HS= 0 m
0 10 20 30 40 50 60 70 80 90 100 110
0 10 20 30 40 50 60 70 80 90
40
SKR 1.5
35
30
25
4
20
15
Head H (metres)
10
5
US g.p.m.
Imp g.p.m.
feet
125
100
75
50
25
0
0 50 100 150 200 250 300 350 400
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
Flow rate Q
MODEL POWER (P)
Single-phase Three-phase kW HP
Service
Factor
SKRm 1.5 SKR 1.5 1.1 1.5 1.3 IE3 H
Q = Flow rate H = Total manometric head HS = Suc tion height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
Performance class of the three-phase motor (IEC 6 0034-30 -1)
 
HS = Suction height
m³/ h 0 3.0 6.0 9.0 12. 0 15.0 18.0 21.0 24.0
Q
l/min 0 50 100 150 200 250 300 350 400
metres
4
36 35.5 34.5 32 29 24.5 19 12. 5 6
l/min
m³/h
0
Non-return valve
GENERAL CATALOGUE 60 Hz | 115
SPRINKLER | 60 Hz
Loading...