Pedrollo PQM65115V Specifications

PQ
Pumps with peripheral impeller
Clean water
Domestic use
PERFORMANCE RANGE
• Flow rate up to 90 l/min (5.4 m³/h)
• Head up to 100 m
APPLICATION LIMITS
• Manometric suction lift up to 8 m
• Liquid temperature between -10 °C and +90 °C
• Ambient temperature between -10 ° C and +40 °C
(+50 °C for PQ 60)
• Max. working pressure:
– 6 bar for PQ 60, PQ 65 – 7 bar for PQ 70, PQ 80 – 10 bar for PQ 90, PQ 100, PQ 200, PQ 300
Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS
EN 6 0335-1 IE C 60 335 -1 CE I 61-15 0
CERTIFICATIONS
Company with management system certied DNV ISO 9001: QUALITY
EN 6 003 4-1 IE C 60 034 -1 CEI 2-3
INSTALLATION AND USE
Suitable for use with clean water that does not contain abrasive particles and with liquids that are not chemically aggressive towards the materials from which the pump is made. The hydraulic characteristics of these pumps, coupled with their compactness, makes them suitable for use in both domestic and industrial applications. The pump should be installed in an enclosed environment or sheltered from inclement weather.
PATENTS - TRADE MARKS - MODELS
• Registered Trade Mark n. 0001520591 PQm 60®
• Motor bracket: patent n. IT1243605
• Shaft: patent n. 0000275945 (PQ60, PQ65)
• Registered EU Design n. 002146548
OPTIONS AVAILABLE ON REQUEST
• Pump body with NPT ANSI B 1.20.1 threaded ports
• Special mechanical seal
• Other voltages
• IP X5 class protection for PQ 70-80-90-100-200-300
GUARANTEE
2 years subject to terms and conditions
60 Hz | PQ
18 | GENERAL CATALOGUE 60 Hz
CHARACTERISTIC CURVES AND PERFORMANCE DATA 60 Hz n= 3450 min HS= 0 m
0 5 10 15 20
0 5 10 15
100
PQ300
90
PQ200
80
70
PQ80
PQ70
60
4
PQ65
50
40
PQ60
Head H (metres)
30
20
10
PQ90
US g.p.m.
Imp g.p.m.
feet
300
250
200
150
100
50
PQ100
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
0 1 2 3 4 5
4
MODEL POWER (P)
Single-phase Three-phase kW HP
PQm 60 PQ 60 0.37 0.50
PQm 65 PQ 65 0.55 0.75
PQm 70 PQ 70 0.60 0.85
PQm 80 PQ 80 0.75 1
PQm 90 PQ 90 0.75 1
IE2
Q
H
m³/ h
l/min
metres
Flow rate Q
0 0.3 0.6 0.9 1.2 1.5 1. 8 2.1 2.4 3.0 3.6 4.2 4.8 5.4
0 5 10 15 20 25 30 35 40 50 60 70 80 90
40 38 33.5 29 24 19. 5 15 10 5
55 50 45.5 40.5 36 31 27 22 17 8
65 62 57 52 47 42 37 32 27 18
70 66 61 56 51 46 41 36.5 31 22
90 82 71 60 49 38 27 17 5
l/min
m³/h
0
IE3
PQm 100 PQ 100 1.1 1.5
PQm 200 PQ 200 1.5 2
PQm 300 PQ 300 2.2 3
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
Three phase motor eciency class (IEC 60034 -30-1)
 
85 80 75 70 65 60 55 50 45 35 25 15
90 86 81 76 71 65.5 60 55 50 40 30 20 10
100 95 90 85 80 75 70 65 60 50 40 30 20 10
GENERAL CATALOGUE 60 Hz | 19
PQ | 60 Hz
Loading...