PEAVEY TriFlex User Manual

TriFlex
Powered Subwoofer and Stereo Satellite System
For more information on other great Peavey products, visit your local Peavey dealer or go online to www.peavey.com
Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s
: :
:
: :
:
: :
T
:
Intended to aler instructions in the literature accompanying the product
CCAAUUTTIIOONN: CCAAUUTTIIOONN:
t the user of the presence of important operating and maintenance (servicing)
.
Risk of electrical shock — DO NOT OPEN! To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside.
Refer servicing to qualified service personnel.
WWAARRNNIINNGG:
To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture.
Before using this appliance, read the operating guide for further warnings.
Este símbolo tiene el propósito, de alertar al usuario de la presencia de “(voltaje) peligroso” sin aislamiento dentro de la caja del producto y que puede tener una magnitud suficiente como par
a
constituir riesgo de descarga eléctrica.
Este símbolo tiene el propósito de alertar al usario de la presencia de instruccones importantes sobre la operación y mantenimiento en la información que viene con el producto
PPRREECCAAUUCCIIOONN: PPRREECCAAUUCCIIOONN:
dentro.
Deje todo mantenimiento en manos del personal técnico cualificado.
AADDVVEERRTTEENNCCIIAA:
Riesgo de descarga eléctrica ¡NO ABRIR! Para disminuír el riesgo de descarga eléctrica, no abra la cubierta. No hay piezas útiles
Para evitar descargas eléctricas o peligro de incendio, no deje expuesto a la lluvia o
.
humedad este aparato Antes de usar este aparato, Iea más advertencias en la guía de operación.
Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur la présence d’une tension dangereuse pouvant être d’amplitude suffisante pour constituer un risque de choc électrique.
Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur qu’il ou qu’elle trouvera d’importantes instructions concernant l’utilisation et l’entretien de l’appareil dans le paragraphe signalé.
AATTTTEENNTTIIOONN: AATTTTEENNTTIIOONN:
Risques de choc électrique — NE PAS OUVRIR!
Afin de réduire le risque de choc électrique, ne pas enlever le couvercle. Il ne se trouve à l’intérieur aucune pièce pouvant être reparée par l’utilisateur. Confiez I’entretien et la réparation de l’appareil à un réparateur
AAVVEERRTTIISSSSEEMMEENNT
: Afin de prévenir les risques de décharge électrique ou de feu, n’exposez pas cet
appareil à la pluie ou à l’humidité. Avant d’utiliser cet appareil, lisez attentivement les avertissement
Peavey agréé.
s
supplémentaires de ce manuel.
Dieses Symbol soll den Anwender vor unisolierten gefährlichen Spannungen innerhalb des Gehäuses warnen, die von Ausreichender Stärke sind, um einen elektrischen Schlag verursachen zu können.
Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam machen, die Handhabung und Wa
VVOORRSSIICCHHTT:: VVOORRSSIICCHHTT::
Risiko — Elektrischer Schlag! Nicht öffnen!
Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es befinden sich keine Teile darin, die qualifiziertem
Fachpersonal durchführen lassen.
rtung des Produkts betreffen.
vom Anwender repariert werden könnten. Reparaturen nur von
AACCHHTTUUNNGG:
Um einen elektrischen Schlag oder F
euergefahr zu vermeiden, sollte dieses Gerät nicht dem
Regen oder Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen.
2
IIMMPPOORRTTAANNTT SSAAFFEETTYY IINNSSTTRRUUCCTTIIOONNS
S
:
!
WWAARRNNIINNGG:
When using electrical products, basic cautions should always be followed, including the following:
1. Read these instructions.
2.
Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any of the
8. Do not install near any heat sources such as radiators, heat registers, amplifiers) that produce heat
ventilation openings. Install in accordance with manufacturer’s instructions.
sto
ves or other apparatus (including
.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding plug. The wide blade or thir prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point they exit from the apparatus.
11. Note for UK
only: If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your
plug‚ proceed as follows: a) The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E‚ the
earth symbol‚ colored green or colored green and yellow. b) The wire that is colored blue must be connected to the terminal that is marked with the letter N or the color black. c) The wire that is colored brown must be connected to the terminal that is marked with the letter
12. Only use attachments/accessories provided by the manufacturer
.
L or the color red.
13. Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
14. Unplug this apparatus during lightning storms or when unused for long periods of time.
15. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in
any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
16. Never break off the ground pin. Write for our free booklet “Shock Hazard and Grounding.” Connect only to a power supply of the type marked on the unit adjacent to the power supply cord.
17. If this product is to be mounted in an equipment rack, rear support should be provided.
18. Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in susceptibility to noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time. The U.S. Go specified the following permissible noise level exposures
vernment’s Occupational and Health Administration (OSHA) has
:
d
Duration
Per Day In Hours Sound Level dBA, Slow Response
8 90 6 92 4 95 3 97 2 100
2
1 1⁄
1 105
1
2
1
⁄4or less 115
According ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss, is in excess of the limits as set forth above. To recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system b protected by hearing protectors while this unit is in operation.
to OSHA, any exposure in excess of the above
ensure against potentially dangerous exposure to high sound pressure levels, it is
permissible limits could result in some hearing loss. Ear plugs or protectors to the
SSAAVVEE TTHHEESSEE IINNSSTTRRUUCCTTIIOONNSS!
3
102
110
if exposure
e
EENNGGLLIISSH
H
TriFlex
Thank you for purchasing the Watts of peak dynamic power to the sub and another 750 Watts of peak dynamic power to the left and right satellite speaker outputs. The TriFlex is designed as a complete package, with a subwoofer driving its own pair of satellite mid/high frequency passive speakers from the left and right power output jacks. There also are facilities for line-level mid/high outputs for driving other mid/high frequency active, separately powered speakers. Alternatively, the TriFlex powered subwoofer can be used as a stand-alone sub.
Featuring TriFlex is one of the most portable, powerful, and flexible 3-way systems available.
Please read this guide carefully to ensure your personal safety as well as the safety of your equipment
Peavey’s patented DDT™compression‚ the awarding-winning KOSMOS®and a Low Rider®Black Widow®woofer, the
Powered Subwoofer and Stereo Satellite System
TriFlex. The TriFlex is designed‚ from start to finish‚ with flexibility in mind. This system delivers 1500
.
Features
Powered system with 1000 Watts of continuous power and 1500 Watts of peak dynamic power
DDT compression (amplifier protection and clip eliminator)
15" Low Rider bass woofer
Peak SPL in excess of 128 dB
KOSMOS sub-harmonic generator system with bypass switch
Left & right power amp outputs with high-pass crossover for the satellites
Built-in electronic crossover with line-level high-pass output
1/4" TRS and female XLR line-level balanced inputs
Male XLR thru output
Compact dimensions
Heavy duty‚ inset handles on both sides
Lockable casters
Two tripod pole stands for the satellite speakers
Heavy duty slip cover, including a bottom cover for amplifier protection
4
Description
The Peavey®TriFlex™is a powered‚ three-way piece speaker system designed to provide the highest levels of performance in a compact package. The subwoofer unit is loaded with the new‚ high power handling 15" Low Rider Black Widow®bass woofer. The TriFlex subwoofer is constructed of premium plywood‚ covered with a tough‚ road­worthy black carpet. A 16-gauge, perforated metal grille with powder-coated finish covers the front of the system to protect the speakers. The TriFlex includes two tripod pole stands for mounting the speakers.
Flexibility is designed into the XLR and 1/4" TRS phone jack plus one male XLR thru, all connected in parallel. The power amplifiers are low­distortion units that supply 1500 Watts of peak dynamic power to the bridged subwoofer, and up to 750 Watts peak dynamic power to the left and right satellite speakers. The amplifiers feature Peavey’s patented DDT™compression that virtually eliminates audible power amplifier clipping.
For ease of transport, inset metal handles on each side of the sub are provided. For pack-up and transport, removable locking casters are located on the rear of the sub. This allows the unit to be rotated onto its back and moved with ease. In this position, the satellites are designed to rest face-to-face on the sub's grille. The entire unit is slipcovered, with a protective flap for the amplifier, which becomes the bottom of the unit when rolled. The speaker cables are placed in the cover pockets and the speaker stands in their own pouches. This makes for a compact and complet package for easy transport.
RREEAARR PPAANNEELL
Fuse (1)
The TriFlex AC is protected from overload and fault conditions with an ABC-type fast-blow 15 Amp fuse. The fuse is located within the cap of the fuse holder. If the fuse fails, THE FUSE MUST BE REPLACED WITH THE SAME TYPE AND VALU IN ORDER TO AVOID DAMAGE TO THE EQUIPMENT AND TO PREVENT VOIDING THE WARRANTY. If the amplifier repeatedly blows the fuse, it should be taken to a qualified service center for repair.
®
TriFlex. Balanced inputs for each channel are provided and include one combo female
e
4
ON
OF
PO WER
E
13
S
E
U
F
F
U
E
S
F
15A
2
120 VAC
60 Hz
600 WATTS
IEC Power Cord Connection (2)
This receptacle is intended to accept an IEC terminated line cord (included) that provides AC power to the unit. It is very important that you ensure the TriFlex is supplied with the proper AC power line voltage. You can find the proper voltage for your TriFlex printed next to the IEC line (power) cord on the rear panel of the unit.
If a North American AC power receptacle is of the two-wire type (i.e., does not include a third wire ground pi
n hole), never circumvent this situation by breaking off the ground pin of the AC power cord. The ground pin is provided for your safety. Suitable grounding adapters are available at your local hardware store. This allows proper third-wire grounding to the AC power outlet cover screw. To prevent the risk of shock or fire, always make sure that all other associated audio equipment is also properly grounded, preferably to the same AC power outlet
breaker circuit.
Power Switch (3)
This rocker switch supplies AC mains power to the TriFlex when in the ON position.
Power LED (4)
This LED illuminates when the Power Switch is in the ON position.
5
Loading...
+ 11 hidden pages