Peavey Special 212 User Manual

Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure
A
A
qualified service personnel. WARNING: To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this
appliance, read the operating guide for further warnings.
A
A
PRECAUCION: Riesgo de corrientazo - No abra. PRECAUCION:
reparar. Deje todo mantenimiento a 10s tecnicos calificados.
that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
Este simbolo tiene el proposito de alertar al usuario de la presencia de “(voltaje) peligroso” que no tiene aislamiento dentro de la caja de1 product0 que puede tener una magnitud suficiente coma corrientazo.
Este simbolo tiene el proposito de alertar al usario de la presencia de instruccones importantes sobre la operation y mantenimiento en la literatura que viene con el producto.
Para
disminuir el riesgo de corrientazo, no
abra
la cubierta. No hay piezas adentro que el usario pueda
para
constituir riesgo de
ADVERTENCIA:
Antes de usar este aparato, lea
Ce symbole est utilise pur indiquer a I’utilisateur la presence a l’interieur de ce produit de tension non-isolee
A
A
ATTENTION: Risques de choc electrique - NE PAS OUVRIR! ATTENTION: Afin de reduire le risque de choc electrique, ne pas enlever le couvercle. II ne se trouve a I’interieur
aucune piece pouvant
AVERTISSEMENT: Afin de prevenir les risques de decharge electrique ou de feu, n’exposez pas cet appareil a la pluie
ou a l’humidite. Avant d’utiliser cet appareil, lisez les avertissements supplementaires situ& dans le guide.
A
A
VORSICHT: Risiko - Elektrischer Schlag! Nicht offnen! VORSICHT: Urn das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es bel‘inden sich
keine Teile darin, die vom Anwender repariert werden konnten. Reparaturen nur von qualifiziertem Fachpersonal
durchftihren lassen.
ACHTUNG: Urn einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses Gerat nicht dem Regen Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen.
dangereuse pouvant
Ce symbole est utilise pour indiquer a l’utilisateur qu’il ou qu’elle trouvera d’importantes instructions sur l’utilisation et l’entretien (service) de l’appareil dans la litterature accompagnant le produit.
Dieses Symbol sol1 den Anwender vor unisolierten gefahrlichen Spannungen innerhalb des Gehauses warnen, die von Ausreichender
Dieses Symbol sol1 den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam machen, die Handhabung und Wartung des Produkts betreffen.
Para
evitar corrientazos o peligro de incendio, no deje expuesto a la lluvia o humedad este aparato
mas
advertencias en la guia de operacidn.
etre
d’intensite suffisante pour constituer un risque de choc electrique.
etre reparee
par l’utilisateur. Confier l’entretien a un personnel qualifie.
Starke
sind, urn einen elektrischen Schlag verursachen zu
konnen.
odei
2
TransTube@
Special’” 212
Congratulations on your purchase of the all new research on vacuum tube emulation, resulting in a totally new Special. The preamp has been redesigned, using patent-applied-for technology that redefines tubelike distortion and harmonic generation in solid-state amps.
The three channels have been voiced dissimilarly to allow for three completely different and extremely versatile tones. The Clean and Lead channels both utilize the passive EQ popularized by the Bandit@
TransTube@,
from the Rockmaster’” preamp. These three channels allow for amazing variations that are instantly attain­able using the remote footswitch.
The new patent-pending T-Dynamics’ circuitry creates the long sought for tube power compression phe­nomenon. This, in combination with resonance and presence circuitry, yields the closest tube amp simulation to date. This compression effect is increased by turning the T-Dynamics’” control down, which lowers the power level the amp puts out.
To further enhance the performance of the Special 212, an added speaker jack along with a footswitchable effects loop allows for even greater flexibility.
FRONT PANEL FEATURES
HIGH GAIN INPUT (1)
Used for most electric guitars. It is 6 dB louder than the Low Gain input.
LOW GAIN INPUT (2)
Provided for instruments that have extremely high outputs that tend to overdrive (distort) the High Gain
input. If both inputs are used simultaneously, the output levels are the same (both are Low Gain).
and the Ultra channel contains a 3-band active EQ-Bottom, Body, and Edge, such as the one
TransTube@
Special@ 212. This amp represents years of
BRIGHT SWITCH (3)
Provides a preset boost (+6
CHANNEL SELECT SWITCH (4)
Allows selection of the Ultra or Clean channel. The “in” position of the switch selects the Ultra channel and the “out” position selects Clean.
Note: Channel selection may also be achieved by the remote footswitch. If remote selection is desired, the channel switch must be in the “in” (Ultra) position.
dB)
to treble frequencies. To activate, depress the switch to its “in” position.
VOLUME (5)
Controls the volume level of the Clean channel.
LOW, MID, & HIGH EQ (6,lO)
Passive tone controls that regulate the low, mid, and high frequencies for the Clean and Lead channels, respectively.
PRE GAIN
(7,12)
Controls the input volume level of the Lead and Ultra channel, respectively.
GAIN SWITCH (8, 13)
Boosts the Gain of the Lead and Ultra channels, respectively. Depress to the “in” position to activate.
THRASH SWITCH (9)
Notches the mid range about 20 dB.
POST GAIN
(11,18)
Controls the overall volume level of the Lead and Ultra channels, respectively. The final level adjustment should be made after the desired sound has been achieved.
BOTTOM (14)
An active tone control (shelving type
_+I5 dB)
that varies the low frequency boost or cut.
Note: This control is functional on the Ultra channel only. BODY (15)
An active tone control (peak/notch
_+15 dB)
that varies the mid frequency boost or cut.
Note: This control is functional on the Ultra channel only. SHIFT SWITCH (16)
Shifts the frequency at which the Body control (15) operates. The “out” position allows the Body control to function at a higher frequency, and the “in” position selects a lower frequency.
EDGE (17)
An active tone control (shelving type
&I5 dB)
that varies the high frequency boost or cut.
Note: This control is functional on the Ultra channel only. REVERB LEVEL (19)
The Reverb level control determines the amount of delayed (reverb) signal mixed back into the output. Its operation in conventional.
RESONANCE (20)
Used to fine-tune the low frequency range of the speaker enclosure by varying the damping factor of the
amplifier at low frequencies.
PRESENCE (21)
Used to fine-tune the high frequency range of the speaker enclosure by varying the damping factor of the
amplifier at high frequencies.
T-DYNAMICS CONTROL (22)
Adjusts the power level of the amplifier from 10 percent to 100 percent power. When set to lower settings, the power compression simulation will be much more pronounced.
POWER SWITCH (23)
Depress the switch to the “on” position. The LED will illuminate indicating power is being supplied to the unit.
Back Panel:
24
Q
BACK
PANEL FEATURES
GROUND SWITCH (24)
Three position rocker-type switch, which, in most applications, should be operated in its center or zero position. There may be some situations when audible hum and/or noise will come from the loudspeaker. If this situation arises, position the ground switch to either positive or negative (+ or -) until the noise is mini­mized.
Note: Should the noise problem continue, consult your Authorized Peavey Dealer, the Peavey Factory, or a qualified service technician. THE GROUND SWITCH IS NOT FUNCTIONAL ON 220/240 VOLT MODELS.
AC LINE CORD-120 V products only (25)
For your safety, we have incorporated a three-wire line (mains) cable with proper grounding
facilities. It is not advisable to remove the ground pin under any circumstances. If it is neces-
A
sary to use the equipment without proper grounding facilities, suitable grounding adaptors should be used. Less noise and greatly reduced shock hazard exists when the unit is oper­ated with the proper grounded receptacles.
EXTERNAL SPEAKER JACK (26)
Provided for connection of external speaker cabinet. Minimum external speaker impedance
is 8 ohms.
A
EFFECTS RETURN (27)
Input for returning signals from external low-level effects or signal processing equipment.
EFFECTS SEND (28)
Output for supplying signals to external low-level effects or signal processing equipment.
EFFECTS LEVEL SWITCH (29)
Selects the effects loop operating level:
POWER AMP INPUT (30)
Used to connect Line Level signal to the power amplifier.
PREAMP OUT (31)
The preamp out can be used to route the amplified signal to a mixing console, tape recorder, etc. Connect the preamp output using a shielded cable to an input of the tape recorder, mixer, etc. This patch does not affect the operation of the amplifier.
REMOTE FOOTSWITCH JACK (32)
Provided for the connection of the supplied remote footswitch. The footswitch is used to select the Ultra Gain, Lead Gain, or Clean channel and defeat Reverb. When using remote footswitch, always insert the plug fully (second click) to ensure proper operation.
-10 dBV (0.3V RMS) when “out” and 0 dBV (1 V RMS) when “in.”
SPECIFICATIONS
Rated Power & Load:
Power specs measured with
T. Dynamics @ 100%
130 W RMS into 8 ohms
220 W RMS into 4 ohms
Power @ Clipping: (typically)
(5% THD, 1 kHz, 120 V AC line)
130 W RMS into 8 ohms
220 W RMS into 4 ohms
Frequency Response:
+O, 3
dB,
60 Hz to 20
@
100 W RMS into 8 ohms
kHz,
Hum 81 Noise:
Greater than 86 dB below
rated power
Power Consumption:
Domestic: 600 W @ 60 Hz,
120 VAC
Export: 600 W @ 50/60 Hz,
220-2301240 V AC
PREAMP SECTION
The following specs are measured 2
kHz
with the controls preset as follows:
Push Bright, Off (out) Channel Select Normal (out) Low& High @ IO Mid @ 0 Resonance & Presence @ 0 Pre & Post Gain @ IO Gain 6: Thrash, Off (out)
Normal Levels are with normal
volume @ 5
Minimum Levels are with normal
volume @ IO Shift, Off (out) Bottom, Body, & Edge @ 0
T-Dynamics @ 100%
@
dB
Preamp High Gain Input:
Impedance: High-Z, 1 M ohm
Nominal Input Level: -24
dBV,
60 mV RMS
Minimum Input Level: -34
dBV,
20 mV RMS
Maximum Input Level: 0
dBV,
1 VRMS
Preamp Low Gain Input:
Impedance: High-Z, 44 k ohms
Nominal Input Level: -18
dBV,
120 mV RMS
Minimum Input Level: -28
dBV,
40 mV RMS
Maximum Input Level: 6
dBV,
2VRMS
Effects Send:
Load Impedance: 1 K ohm
or greater
Nominal Output Level: -10
0.3 V RMS or 0
dBV,
dBV,
1 V RMS
if Effects Level is in
Effects Return:
Impedance: High-Z, 18 K ohms Designed Input Level: -10
0.3 V RMS or 0
dBV,
dBV,
1 V RMS
if Effects Level is in
(Switching jack provides Effects Send to Effects Return connection when not used)
Preamp Output:
Load Impedance: 1 K ohm
or greater
Nominal Output Level: 0
dBV,
1 VRMS
Power Amp Input:
Impedance: High-Z, 50 K ohms
Designed Input Level: 0
dBV,
1 VRMS
(Switching jack provides preamp output to
power amp input connection when not
used)
System Hum & Noise
@
Nominal Input Level:
(20 Hz to 20
kHz
un weigh ted)
72 dB below rated power
Equalization:
Special Low, Mid, & High
passive type EQ
Special Bottom, Body, &
Edge EQ
Push Bright: +6 dB @ 2
kHz
Push Shift: Shifts Ultra Channel
Body Frequency
Push Thrash: -20 dB notch
1
kHz
in Lead channel
@
Push Gain: Increases Lead or
Ultra gain
Resonance: +6 dB @ cabinet
resonance
Presence: +6 dB @ 5
kHz
External Footswitch Functions:
Lead/Ultra Select (when
Channel Select button is in) Clean Bypass Effects Loop Bypass
Dimensions 81 Weight:
20.75” H x 26.625” W x 11.75” D
64.8 Ibs.
,feutures
and specifications
R.O.C. Invention Patent No. 072727
Due to our
efSorts,for
LiJ
constant improvements,
ted herein are subject to charge without notice.
6
Loading...