Peavey Revolution 9-9880304470, Revolution 112 TransTube User Manual

2
Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
CAUTION: Risk of electrical shock — DO NOT OPEN! CAUTION: To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside. Refer
using this appliance, read the operating guide for further warnings.
Este símbolo tiene el propósito, de alertar al usuario de la presencia de “(voltaje) peligroso” que no tiene aislamiento dentro de la caja del producto que puede tener una magnitud suficiente como para constituir riesgo de corrientazo.
Este símbolo tiene el propósito de alertar al usario de la presencia de instruccones importantes sobre la operación y mantenimiento en la literatura que viene con el producto.
PRECAUCION: Riesgo de corrientazo — ¡No abra! PRECAUCION: Para disminuír el riesgo de corrientazo, no abra la cubierta. No hay piezas adentro que el usario
pueda reparar. Deje todo mantenimiento a los técnicos calificados. ADVERTENCIA: Para evitar corrientazos o peligro de incendio, no deje expuesto a la lluvia o humedad este
aparato Antes de usar este aparato, Iea más advertencias en la guía de operación.
Ce symbole est utilisé pur indiquer à l’utilisateur la présence à l’intérieur de ce produit de tension non­isolée dangereuse pouvant être d’intensité suffisante pour constituer un risque de choc électrique.
Ce symbole est utilisé pour indiquer à l’utilisateur qu’il ou qu’elle trouvera d’importantes instructions sur l’utilisation et l’entretien (service) de l’appareil dans la littérature accompagnant le produit.
ATTENTION: Risques de choc électrique — NE PAS OUVRIR! ATTENTION: Afin de réduire le risque de choc électrique, ne pas enlever le couvercle. Il ne se trouve à l’intérieur
aucune pièce pouvant être reparée par l’utilisateur. Confier I’entretien à un personnel qualifié. AVERTISSEMENT: Afin de prévenir les risques de décharge électrique ou de feu, n’exposez pas cet appareil à la
pluie ou à l’humidité. Avant d’utiliser cet appareil, lisez les avertissements supplémentaires situés dans le guide.
Dieses Symbol soll den Anwender vor unisolierten gefährlichen Spannungen innerhalb des Gehäuses warnen, die von Ausreichender Stärke sind, um einen elektrischen Schlag verursachen zu können.
Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam machen, die Handhabung und Wartung des Produkts betreffen.
VORSICHT: Risiko — Elektrischer Schlag! Nicht öffnen! VORSICHT: Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es befinden
sich keine Teile darin, die vom Anwender repariert werden könnten. Reparaturen nur von qualifiziertem Fachpersonal durchführen lassen.
ACHTUNG: Um einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses Gerät nicht dem Regen oder Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen.
Congratulations on your purchase of the all new Revolution®112 TransTube®Series amplifier. This amp represents years of research on vacuum tube emulation and channel switching configurations, resulting in a totally new TransTube package. The preamp has been designed using technology that redefines tube-like distortion and harmonic generation in solid-state amps.
The T
Dynamics circuitry simulates tube power amp compression. This, in combination with reso­nance and presence circuitry, yields the closest tube amp simulation to date. This compression effect is increased by turning the T™Dynamics control down, which lowers the power level of the amp.
Using the Revolution®112 with an external 8 ohm speaker, like our 112 SX, increases the power from 80 to 100 watts. The footswitchable channel selection and the footswitchable effects loop allow for greater flexibility in performance.
FRONT PANEL FRONT PANEL FEATURES HIGH GAIN INPUT (1)
Used for most electric guitars. It is 6 dB louder than Low Gain input.
LOW GAIN INPUT (2)
Provided for instruments that have extremely high outputs, which can result in overdriving (distorting) the High Gain input. If both inputs are used simultaneously, the output levels are the same (both are Low Gain).
VOLUME (3)
Controls the volume level of the Clean channel.
BRIGHT SWITCH (4)
Provides a preset boost (6 dB) to treble frequencies. To activate, depress the switch to its “in” position.
CHANNEL SELECT SWITCH (5)
Allows selection of the Ultra or Clean channel. The “in” position of the switch selects the Ultra channel and the “out” position selects Clean.
NOTE: Channel selection may also be achieved by the remote footswitch. If remote selection is desired, the channel switch must be in the “in” position.
LOW, MID, AND HIGH EQ (6)
Passive tone controls that regulate the low, mid, and high frequencies of the Clean channel.
3
ENGLISH
1
6
2 3
4
5
9 13
21
7 8 10 11 12 14 15 16 17 18 19 20 22 23
PRE GAIN (7)
Controls the input volume level of the Lead channel.
THRASH SWITCH (8)
Notches the mid range about 20 dB.
LEAD GAIN SWITCH (9)
Boosts the Lead channel gain. Depress to the “in” position to activate.
POST GAIN (10)
Controls the overall volume level of the Lead channel. The final level adjustment should be made after the desired sound has been achieved.
PRE GAIN (11)
Controls the input volume level of the Ultra channel.
MID BOOST SWITCH (12)
Provides a preset boost (3 dB) to mid frequencies in Ultra channel.
ULTRA GAIN SWITCH (13)
Boosts the Ultra channel gain. Depress to the “in” position to activate.
POST GAIN (14)
Controls the overall volume level of the Ultra channel. The final level adjustment should be made after the desired sound has been achieved.
BOTTOM (15)
An active tone control (shelving type ±15 dB) that varies the low frequency boost or cut.
BODY (16)
An active tone control (peak/notch ±15 dB) that varies the mid frequency boost or cut.
EDGE (17)
An active tone control (shelving type ±15 dB) that varies the high frequency boost or cut.
REVERB LEVEL (18)
The Reverb level control determines the amount of delayed (reverb) signal mixed back into the output.
MASTER LEVEL (19)
Controls overall system level. (Affects all channels)
PRESENCE (20)
Used to fine-tune the high frequency range of the speaker enclosure by varying the damping factor of the amplifier at high frequencies.
RESONANCE SWITCH (21)
Used to fine-tune the low frequency range of the speaker enclosure by varying the damping factor of the amplifier between two preset values.
T-DYNAMICS CONTROL (22)
Adjusts the power level of the amplifier from 10 percent to 100 percent power. When set to lower settings, the power amp compression simulation will be more pronounced.
POWER SWITCH (23)
Depress the switch to the “on” position. The LED will illuminate indicating power is being supplied to the unit.
4
BACK PANEL FEATURES GROUND SWITCH (24)
Three position rocker-type switch, which, in most applications, should be operated in its center or zero position. There may be some situations when audible hum and/or noise will come from the loudspeaker. If this situation arises, position the ground switch to either positive or negative (+ or -) until the noise is minimized.
Note: Should the noise problem continue, consult your Authorized Peavey Dealer, the Peavey Factory, or a qualified service technician. THE GROUND SWITCH IS NOT FUNCTIONAL ON
220/240 VOLT MODELS.
AC LINE CORD—120 V PRODUCTS ONLY (25)
For your safety, we have incorporated a three-wire line (mains) cable with proper grounding
facilities. It is not advisable to remove the ground pin under any circumstances. If it is necessary to use the equipment without proper grounding facilities, suitable grounding adaptors should be used. Less noise and greatly reduced shock hazard exists when the unit is operated with the proper grounded receptacles.
(For UK Only) As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
• The wire which is coloured green and yellow must be connected to the terminal which is marked by the letter E or by the earth symbol, or coloured green or green and yellow.
• The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
• The wire which is coloured brown must be connected the terminal which is marked with the letter L or the coloured red.
EXTERNAL SPEAKER JACK (26)
Provided for connection of external speaker cabinet. Minimum external speaker impedance is 8 ohms. Use of an external 8 ohm speaker boosts amp output to 100 watts.
REMOTE FOOTSWITCH JACK (27)
Provided for the connection of the supplied remote footswitch. The footswitch is used to select the Ultra, Lead, or Clean channel and bypass the EFX Loop. When using remote footswitch, always insert the plug fully (second click) to ensure proper operation. The proper footswitch is Peavey part number 90000019.
POWER AMP INPUT (28)
Used to connect Line Level signal to the power amplifier.
5
24
25 26 27 28 29 30 31 32
BACK PANEL
6
PREAMP OUT (29)
The preamp out can be used to route the amplified signal to a mixing console, tape recorder, etc. Connect the preamp output using a shielded cable to an input of the tape recorder, mixer, etc. This patch does not affect the operation of the amplifier.
EFFECTS LEVEL SWITCH (30)
Selects the effects loop operating level: -10 dBV (0.3V RMS) when “out” and 0 dBV (1V RMS) when “in.”
EFFECTS RETURN (31)
Input for returning signals from external low-level effects or signal processing equipment.
EFFECTS SEND (32)
Output for supplying signals to external low-level effects or signal processing equipment.
7
REVOLUTION®112 SPECIFICATIONS
Power Amplifier Section:
The following specs are measured at 1 kHz with the master EQ set flat at 0 dB, all gain switches in the out position, the main reverb at 0, nominal signal levels are with channel level controls set at 5, minimum level are with channel level controls set at 10.
Rated Power and Load:
Power specs measured with T™Dynamics @ 10
80 W RMS into 8 ohms 100 W RMS into 4 ohms
Power @ Clipping: (typically)
(5% THD, 1 kHz, 120 V AC line)
80 W RMS into 8 ohms 100 W RMS into 4 ohms
Frequency Response:
+0/-3 dB 65 Hz to 20 kHz @ 65 W RMS into 8 ohms
Hum and Noise:
Greater than 80 dB below rated power
Power Consumption:
300 W @ 60 Hz, 120 V AC, Domestic 300 W @ 50/60 Hz, 220-230/240 V AC, Export
PREAMP SECTION
The following specs are measured @ 1 kHz with the controls preset as follows:
Push Bright, Off (Out) Channel Select Clean (Out) Low & High @ 10 Mid @ 0 Lead Pre & Post Gain @ 10 Lead Gain & Mid Boost, Off (Out) Ultra Pre & Post @ 10 Ultra Gain & Mid Boost, Off (Out) Bottom, Body & Edge @ 0 Reverb @ 0 Master Level @ 10 Normal Levels are with Clean Volume @ 5 Minimum Levels are with Clean Volume @ 10
Preamp High Gain Input:
Impedance: High-Z, 1 M ohm Nominal Input Level: -15 dBV, 175 mV RMS Minimum Input Level: -25dBV, 55 mV RMS Maximum Input Level: 0 dBV, 1 V RMS
Preamp Low Gain Input:
Impedance: High-Z, 44 K ohms Nominal Input Level: -9 dBV, 350 mV RMS Minimum Input Level: -19 dBV, 110 mV RMS
Maximum Input Level: 6 dBV, 2 V RMS
Effects Send:
Load Impedance: 1 K Ohms or greater Nominal Output Level:
Efx. Level switch “out”: -10dBV, 0.3V RMS Efx. Level switch “in”: 0dBV, 1V RMS
Effects Return:
Impedance: High-Z, 22 K ohms Designed Input Level:
Efx. Level switch “out”: -10dBV, 0.3V RMS
Efx. Level switch “in”: 0dBV, 1V RMS
(Switching jack provides Effects Send to Effects Return connec­tion when not used)
Preamp Output:
Load Impedance: 1 K ohm or greater Nominal Output Level: 0 dBV, 1 V RMS
Power Amp Input:
Impedance: High-Z, 25K Ohms Designed Input Level: 0 dBV, 1 V RMS
(Switching jack provides preamp output to power amp input con­nection when not used)
System Hum and Noise @ Nominal Input Level:
(20 Hz to 20 kHz unweighted)
Greater than 70 dB below rated power
Equalization:
Special Low, Mid, and High passive type EQ
(Clean channel only) Push Bright: +6 dB @ 2 kHz (Clean channel only) Special Bottom, Body, and Edge active EQ (Lead and
Ultra channels) Push Thrash: -12 dB @ 1 kHz (Lead channel) Push Mid Boost: +3dB @ 1kHz (Ultra channel only) Push Gain: Increases gain (Lead and Ultra channels) Presence: +6dB @ 5kHz Push Resonance: +6 dB @ resonant frequency of cabinet
External Footswitch Functions (part number 90000019):
Ultra/Lead: Selects Ultra or Lead channel Bypass/Clean: Lead and Ultra channel defeat
(with front panel Channel switch “in”)
Select Effects: Effects loop bypass
Dimensions and Weight:
20.0” H x 23.5” W x 11.375” D (50.8 cm x 59.7 cm x 28.9 cm)
45.9 lbs. (20.8 kg)
8
CLEAN
HIGH
PRE GAIN LEAD
PUSH THRASH
LO MID HI
TONE
POST
LEAD
BOT. BODY EDGE
EQUALIZATION
EFX LEVEL
EFX. SEND
EFX. BYPASS
FOOT SWITCH
RETURN
EFX.
REVERB
LEVEL
PREAMP OUT
POWER AMP IN
POST
ULTRA
PUSH MID BOOST
SPEAKER
EXTERNAL SPEAKER
PRESENCE
MASTER LEVEL
T.DYNAMICS
REVOLUTION BLOCK DIAGRAM (FLOWCHART)
POWER AMP
INPUTS
1st
PUSH BRIGHT
RESONANCE
VOLUME CLEAN
FOOT SWITCH
PUSH CHANNEL
GAIN STAGE
CLEAN/ULTRA
SWITCH LOGIC
PUSH GAIN
ULTRA
ULTRA
PREGAIN
ULTRA
SWITCH
FOOT
SWITCH LOGIC
LEAD/
PUSH GAIN
LEAD
GAIN AMP
REVOLUTION®112
BLOCK DIAGRAM
(FLOWCHART)
Loading...
+ 16 hidden pages