Peavey CS 1000X User Manual

Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure
A
A
CAUTION: Risk of electrical shock - DO NOT OPEN! CAUTION: To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to
qualified service personnel. WARNING: To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this
appliance, read the operating guide for further warnings.
A
that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
Este simbolo tiene el proposito de alertar al usuario de la presencia de “(voltaje) peligroso” que no tiene aislamiento dentro de la caja corrientazo.
del
product0 que puede tener una magnitud suficiente coma para constituir riesgo de
Este simbolo tiene el propdsito de alertar al usario de la presencia de instruccones importantes sobre la
A
PRECAUCION: Riesgo de corrientazo ~ No PRECAUCION: Para disminuir el riesgo de corrientazo, no reparar. Deje todo mantenimiento a
ADVERTENCIA: Antes de usar este aparato, lea mas advertencias en la guia de operation.
I
A
A
ATTENTION: Risques de choc Clectrique ~ NE PAS OUVRIR! ATTENTION: Afin de reduire le risque de choc electrique, ne pas enlever le couvercle. 11 ne se trouvc a aucune piece pouvant
AVERTISSEMENT: Afin de prevenir ou a
I
y mantenimiento en la literatura que viene con el producto.
abra.
abra
la cubierta. No hay piezas adentro que el usario pueda
10s
tecnicos calificados.
Para
evitar corrientazos o peligro de incendio, no deje expuesto a la lluvia o humedad este aparato
Ce symbole est utilise pur indiquer a I’utilisateur la presence a l’interieur de ce produit de tension non-isolee dangereuse pouvant
Ce symbole est utilise pour indiquer a l’utilisateur qu’il ou l’utilisation et I’entretien (service) de
I’humidite.
Avant d’utiliser cet appareil, lisez
&tre
reparee par
&tre d’intensite
I’utilisateur.
les
suffisante pour constituer un risque de choc electrique.
qu’elle
trouvera d’importantes instructions sur
I’appareil
risques de
dans la litterature accompagnant le produit.
Confier l’entretien a un personnel qualifie.
d&charge
electrique ou de feu, n’exposez pas cet appareil a la pluie
let
avertissements supplementaires situ& dans le guide.
operation
I
I’interieur
I
Dieses Symbol
A
A
VORSICHT: Risiko - Elektrischer Schlag! Nicht offnen! VORSICHT: keine Teile darin, die vom Anwender repariert werden konnten. Reparaturen nur von qualifiziertem Fachpersonal durchfiihren
ACHTUNG: Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung
von Ausreichender Starke sind,
Dieses Symbol Handhabung und Wartung des Produkts betreffen.
Urn
lassen.
Urn
sol1
den Anwender vor unisolierten gefahrlichen Spannungen innerhalb des Gehauses warnen, die
urn
einen elektrischen Schlag verursachen zu konnen.
sol1
den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam machen, die
das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es befinden
einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses
2
Icsen.
Get-at
nicht dem Regen oder
sich
A
For optimum performance and reliability DO NOT PRESENT THE AMPLIFIER WITH A SPEAKER LOAD OF LESS THAN 2 OHMS, OR A COMBINATION OF SPEAKERS THAT TOGETHER ARE LESS THAN 2 OHMS!
Using one speaker, it must be rated at 2 ohms minimum. Using two speakers, they must be rated each at 4 ohms minimum.
Using three speakers, they must be rated each at 8 ohms minimum.
WARNING!
The world-famous
CS@
1000X. This upgraded model provides impressive
C!F
1000 power amplifier has been changed to the new, extended-performance
2-ohm
output power capability while still maintain­ing the current 4- and &ohm ratings, and meets rigid industry standards for power bandwidth, slew rate, and distortion specifications.
The new extended specs are:
525 W RMS into 4 ohms / 750 W RMS into 2 ohms (per channel)
1050 W RMS into 8 ohms / 1500 W RMS into 4 ohms (bridged)
DDTTM
compression with LED indicators and defeat switch Slew Rate: 40 V/microsecond, stereo mode, each channel Power Bandwidth: 10 Hz to 50 kHz @ 4 ohms, rated power Total Harmonic Distortion: less than
0.03%,
rated power
Hum and Noise: 100 dB below rated power, unweighted
All the current features of the previous units have been retained, including Peavey’s patented
DDTTM
com­pression system and the very flexible back-panel patching capabilities. The two-speed fan cooling system has been improved to automatically provide additional cooling for the two-ohm load conditions.
FEATURES
. . . . . . . . .
l
.
.
.
Automatic two-speed fan cooling system/tunnel Independent channel thermal/fault protection Transient-free turn-on/off operation (relay) Two “back-porch” crossover “island” sockets for plug-in modules Two “back-porch” balanced-input transformer sockets for PL-2’s Single XLR and dual phone plug inputs each channel XLR input can be transformer-balanced Dual phone plug and 5-way binding post outputs each channel High temperature shutdown LED each channel
DDTTM
activation LED each channel Ten-segment, tri-colored power level LED array each channel
Calibrated/detented input attenuator control each channel
Rear panel
DDT
TM
defeat and bridge mode select slide switches
DDTTM
The
ACTIVE
DDTTM
active
LEDs
LEDs
(1)
indicate when compression is taking place. As long as gain reduction is occurring, the LED will continue to light, thereby giving a valuable indication of this unique compression function. The DDT function can be defeated on both channels simultaneously by selecting the defeat position on the DDT compression switch (7) located on the back panel of the CS 1000X. When the compressor is defeated, the DDT active LED will indicate clipping, this being the condition where the amp is failing to faithfully reproduce the input signal. A more thorough discussion of the DDT function is included later in this manual.
HIGH TEMPERATURE
LEDs
(2)
These LEDs illuminate whenever the thermal logic system has determined that a particular channel is operating above safe temperature limits and has shut down the unsafe channel. When this LED is illumi­nated, the CS 1000X if either or both channels are continuously operated into less than
“0”
LED will also go out on that channel. Excessive temperature conditions can occur in the
2-ohm
loads (or a short cir­cuit), or if the ambient temperature of the air supply becomes too hot to provide adequate cooling even under normal
2-ohm
or greater loading situations. Since the CS 1000X is a “redundant” amplifier, the shutdown of one channel will not affect the operation of the other channel. When the unsafe channel has cooled down to safe limits, operation will be restored in that channel. Normal operation is indicated when the high temperature LED is off and the
“0”
LED is on. Continued operation under fault conditions will not harm the amplifier, but because of the nuisance factor, steps should be taken to determine the problem and solve it.
LED ARRAYS (3)
The CS 1000X has a tri-colored LED array on each channel to indicate the output power level. The LED array is calibrated in two different ways to offer maximum flexibility and ease of use. In the center of the LED ladder, the calibration is percent of full power output. The top LED, labeled
lOO%,
will flash when the CS 1000X has reached full RMS power output capability on that particular channel. Operation at power output levels below 100% will naturally be indicated by lower LED readings. The lowest value indicated is
0.4% of full power, which corresponds to 2.0 watts RMS output into 4 ohms. Operation below that power level will not be indicated, since the lowest LED is calibrated at 0% or standby. As mentioned, this LED should be illuminated whenever the amplifier is operating with AC mains power applied under zero signal
4
conditions. Next to each ladder the calibration is indicates the amount of power amp headroom left for any signal condition.
INPUT SENSITIVITY CONTROLS (4)
The CS show the actual input sensitivity ratings of the amplifier for various settings in decibel volts necessary to attain the full-output power rating. Thus, maximum input gain (minimum sensitivity rating) is achieved at the full clockwise setting, and this setting yields maximum mixer/system headroom. A setting of less than full clockwise will yield lower system noise at the expense of mixer/system headroom. A more thorough discussion of input sensitivity follows later in this manual.
MAINS POWER SWITCH (5)
A
The front panel of the CS 1000X contains a conventional on/off rocker switch. When the amplifier is plugged into a suitable power source, activating this switch should light both channel the power-up delay sequence is completed (approximately two seconds). You should also be able to hear the output relays close (click). If the amplifier is cool, the fan should start on low-speed operation. If only one channel indicator lights, check the rear panel circuit breaker and the mains power source. It’s always a good idea to check to see that the cooling fan is operational, especially on a new unit. The possibility exists that due to shipping and handling, the fan bearings may be too tight to allow low-speed fan operation. If this is the case, immediately seek professional help. The CS 1000X must have normal fan operation to provide adequate cooling for the unit. Without air flow, the amplifier will “thermal” very quickly under any signal conditions.
1000X
“0”
features a 31 detent, calibrated sensitivity control for each channel. Each control is labeled to
indicator lights, then the possibility exists of an internal “fault.” If neither channel
“dB
below full power.” This is a convenient scale that
“0”
array
LEDs
“0”
after
9
8
57
GRILLE (6)
The back panel includes the fan opening with protective grille amplifier. This opening should never be blocked or restricted.
DDT SWITCH (7)
This switch is used to either ENABLE or DEFEAT the DDT compressor. Defeating the DDT compressor should not be performed lightly or simply as a matter of course. Most loudspeaker systems simply cannot handle the square wave power of the CS speakers to be damaged.
1000X,
and defeating this valuable limit can eventually cause the
(6)
where cooling air is drawn into the
6
i’
A
MAINS POWER SOURCE (120V products only) (8)
The CS plug with a ground pin. It should be connected to an independent mains circuit capable of delivering at least
15 AMPS continuously. This is particularly critical for sustained high-power applications. If the socket does
not have a ground pin, a suitable ground lift adaptor should be used, and the third wire grounded properly.
1000X
is fitted with a single heavy-duty
#14
AWG 3 conductor line cord and a conventional AC
5
Never break off the ground pin on the CS 1000X or any amplifier. The use of extension cords should be avoided, but if essential, always use a three-wire type with at least a wire will severely limit the power capability of this amplifier. Always use a qualified electrician to install
any necessary electrical equipment. To prevent the risk of shock or fire hazard, always be sure that the amplifier is properly grounded.
CIRCUIT BREAKER (9)
The new CS 1000X now features a circuit breaker in place of the mains fuse. This breaker is provided to
A
limit the mains current to the associated power transformer, thereby protecting it from overheating and possible destruction due to any fault conditions in the amplifier. The trip current value has been carefully chosen to allow continuous power output performance, while still providing adequate protection for the power transformer itself. Normally the breaker should not trip; however, abnormal conditions such as a
short circuit on either or both channels, or continuous operation at overload or clipping, especially into a
2-ohm
the overload. When tripped, the button on the breaker will be extended outward nearly l/2” and can be reset by pushing inward. A normal reset button length is about l/4”.
simply pushing the button back in will reset it, after waiting a brief period of time to allow it to cool down. If the breaker trips instantly each time you attempt to reset it, then the unit should be taken to a qualified
service center for repair.
The back panel of the CS 1000X features a unique “back-porch” design containing the various input and
output connectors for each channel. A patch panel is also included, providing a very flexible system for use
with balanced-input transformers and dual crossover networks. These features are unduplicated in any other
stereo power amplifier on the market today.
load, will cause the breaker to trip. If this occurs, simply reset the breaker and correct the cause of
#14
AWG wire size. The use of lighter
If this “thermal”-type breaker does trip,
MODE SWITCH (10)
The mode switch is located on the “back-porch” next to the channel input jacks. This switch converts the
CS 1000X from normal stereo mode to bridge mode. Bridge-mode operation is very popular for commercial
sound distribution systems
WARNING: In bridge mode, the CS 1000X is capable of delivering 1000 W RMS into 8 ohms and
1500 W RMS into 4 ohms. Always be very certain that the associated loudspeaker system can handle this
A
power level reliably. Also, be advised that in most crossover applications, accidental switching to the bridge mode could destroy the speaker system. Specific applications of the bridge mode will be covered later in this manual.
(70/100
volt lines).
6
Loading...
+ 14 hidden pages