PeakTech 9018 User Manual

1. Operating safety precautions
This product complies with the requirements of the following European Community Directives: 89/336/EC (Electromagetic Compatibility).
g Introduction
This electronic measuring instrument is a high technology product made under strict quality control. We guarantee this exceptional precision and utmost reliability. To ensure safe operation of this instrument, be sure to follow the warning and precautions provided as bellow.
g Warning
Do not use this product or equipment connected to it in an explosive, ignitable, or flammable atmosphere, as this will result in the risk of explosion.
Do not connect this product to a piece of equipment or cable having a voltage with respect to ground on its chassis, as such connection can result in the risk of electrical shock.
Use a proper Battery charger for charging internal rechargeable battery pack.
g Caution
Do not remove the case cover, as this can risk failures or loss of performance.
Do not allow water to enter the product. This product is not waterproof.
If condensation forms on this product due to a sudden change in temperature, use this product only after allowing it to dry sufficiently.
2. Product description
2.1. Introduction
This professional CATV/TV Level Meter has been designed for the installation and maintenance of Cable TV and VHF/UHF TV system. The inside circuitry and mechanical design has been carefully developed in order to obtain very light, slim typed field strength meter. To allow the installer to work in the best conditions, it is also offering built-in power (rechargeable battery) and hang-on-the neck type carrying case. The LCD display with Back-light is shown several kinds of information such as Frequency, Measuring level, Function, units and bar graph. The compact metal cabinet will be a right choice for heavy-duty field use. It is a real instrument to measure, verify and optimize Cable TV and VHF/UHF TV systems at any stage of installation.
-19-
2.2. Features
* Handheld, portable CATV/TV SIGNAL STRENGTH METER * PLL tuning control for Frequency Selection (5 - 862MHz) * Audio Sub-Carrier frequency selection (4.5; 5.5; 6.0; 6.5MHz) * AC/DC Voltage measurement (Up to 70 V) * Built in Rechargeable Battery pack for powering * Auto power off * 99 Favorite Channel memory * Peak holder function for detecting Max. Input level Display * Buzzer for Acoustic signal strength monitoring * Multi LCD display with Back light * Last condition Store & memory * Key Entry control * Deluxe HANG-ON-NECK type CARRYING CASE for hand-free use
3. Technical Specification * Measuring Frequency Range 5 to 862 MHz
* Frequency Tuning Resolution 250 kHz
* Frequency Tuning Method PLL Frequency Synthesizer
* Level Measurement
- Measuring Range 30 to 120 dBuV
- Resolution 0.1 dB
- Accuracy ± 3 dB (0 to 40°C)
* RF Input F type, 75 ohm
* Audio sub-carrier(fs-fp band width) A: +4.5MHz, B: +5.5MHz
C: +6MHz, D: +6.5MHz
* DC Voltage Measurement 70V
* AC Voltage Measurement 70V
* Favorite Channel Memory
- Number of channels 99
- Storable Items Frequency: 5 – 862MHz in 250kHz step
Function: Video, Peak
holder Sound; Unit of Level: dBuV, DC V, Audio Sub­carrier: A:4.5MHz, B:5.5MHz, C:6MHz, :6.5MHz
-20-
* Auto power off Preset to 10 Minutes
* Internal Power
-Capacity of Rechargeable Battery 12 V/1200 mA AH (Metal Hydride)
-Battery Life 3 HRS
* Power requirement for charging DC12V 500mA (Charge & Adaptor)
* Display Multi LCD Display with
Back-light Frequency, Channel, Level, dBuV, VDC, VAC Function, Battery level, Audio Sub­Carrier BW, Bargraph
* Environmental Conditions
- Operating Temperature Range 0 to 40 °C
- Operating Humidity Range 30 to 85 % RH
- Storage Temperature Range -10 to 50 °C
* Dimensions in mm and Weight 180(W) x 75(H) x 150(D)
approx. 1.5 kg
* Supplied Standard Accessories Battery Charger
(12V 500mA), Carrying Case, User’s Manual
4. Installation
4.1. Initial Inspection
This instrument was carefully inspected both mechanically and electrically before shipment. It should be physically free of damage. To confirm this, the instrument should be inspected for physical damage in transit. Also, check for supplied accessories.
4.2. Charging and Discharging Instruction
a. New batteries are supplied in an uncharged state. To ensure the maximum battery performance, a new battery (or long time not­ used-battery) should be charged for at least 10 hours before use. b. A new battery will require several full-charge/discharge cycles in order to achieve its optimum performance. After 1
st
full charge, use battery until full discharge level, and 2nd charge to full level, Repeat this cycle several times before starting the main use of battery.
-21-
c. Best battery performance will be achieved when you regularly charge and discharge batteries. d. If left unused, a fully charged battery will discharge itself in approximately one month.
** Please refer to “7.2 Battery Charging, page 4-1“ for the details of charging method.
4.3. Cooling and Ventilation
No special cooling and ventilation is required. However, the instrument should be operated where the ambient temperature is maintained.
5. Operating procedure
5.1. Front Panel Description
5 4 3 1 2
1. Power; Power on / off (Momentary switch). Turning on the power with beep sound when the switch is pressed.
2. Input Terminal; Accepts signal from CATV system(Wall plate, Head-end system and etc.) or signal from VHF/UHF antenna.
Caution Maximum input is Signal: 120dBuV AC/DC Voltage: 70V.
Excessive voltage can damage to internal circuit.
-22-
3. Function;
- Set the frequency, Function, Output Signal and units.
- Store the function and data for desired channel and call the stored channel.
- Turning on back-light.
Use to select the function of Up/Down key. (Frequency, Channel, Function, Audio Sub-carrier, unit) Use to store the desired conditions of eachc channel(push two times) (Frequency, Function, Audio Sub-carrier, measuring unit) Use to change the measuring conditions in selected channel momently (push one time)
Use to call stored channel
Use to turn on and off back light Use to change the value in selected function by
key.
- Change of Frequency (From 5MHz to 862MHz in 250kHz step)
- Change of Channel (CH 01,02,… up to 99)
(Up)
(Down)
- Change of function (Video/ Audio, Normal/ Peak holder/ Sound)
- Change of Audio sub-carrier(fs-fp BW) (A,B,C,D)
- Change of measuring unit (dBuV, VDC/VAC­Auto selection by input voltage)
4. LCD Display; Displays measurement level and various informations.
5. DC INPUT for charging internal battery pack;
Accepts external DC power from AC adaptor and Cigar socket of Car for charging internal battery pack. When the AC Adaptor is used for charging, DC 12V 500mA is required. The input power jack could be accepting with center plus (+).
-23-
5.2. LCD Panel Description
1
_
2 3 ^
4
5 ]
1. Bar-Graph; Displays signal level. Minor division indicates
2.25 dBuV. Same quantities of bar will be dis­ played with input level from 30dBuV to 120dBuV.
2. Video/Audio Displays Video or Audio level measurement
3. Function (Peak holder/Sound, Battery level) Displays selected function (Peak/Sound) and the level of internal battery pack.
4. Channel Displays selected channel number.
5. Level Displays signal level with dBuV and Line voltage from Cable with VDC and VAC.
* VDC/ VAC is selected automatically
according to input voltage
-24-
] Frequency
Displays selected Video carrier frequency.
^ Units
Displays selected units (dBuV for level, VDC or VAC for Voltage)
_ Audio sub-carrier(fs-fp band width) Displays selected audio sub-carrier A; +4.5MHz, B: +5.5MHz, C: +6MHz, D: +6.5MHz
5.3. Basic Operation
5.3.1. Connecting with CATV System
Connect the signal from
CATV system(Wall plate, Head-end system
or others) to INPUT Connector of this meter using a 75ohm coaxial cable.(See figure 3-1)
Fig. 3-1 Connecting with LNB
5.3.2. Connecting with UHF/VHF Antenna
Figure 3-3 is shown a set-up example for Connect the signal from UHF/VHF Antenna to INPUT Connector of this meter using a 75ohm coaxial cable.
Fig. 3-3 Setup for Multi-Site viewing
-25-
5.3.3. Change of Frequency to measure
The frequency can be changed in initial status of operation and after selecting Channel.
a. Select desired frequency to measure level by using “Up”,“Down” key. (5MHz – 862MHz with 250kHz step)
** The frequency change is speed up by pressing “Up/Down” key for fast change of frequency.
b. Move to other selecting function by using “Shift” key or push “Store” key(two times) to store.
5.3.4. Selection of Video/Audio measurement
The Audio level can be measured and displayed as follows: a. Move to “Video/Audio” selection by using “Shift” key". “Video” will be blinking.
b. Select “Video” or “Audio” function by using “Up/Down” key.
c. Move to other selecting function by using “Shift” key.
NOTE: Audio function cannot be stored in channel memory. The default setting of level is “Video”.
5.3.5. Setup Function of measurements
The measuring function (Normal, Peak Holder, Sound monitoring) can be selected.
a. Move to “Function” selection group by using “Shift” key. Function group will be blinking.
b. Select desired function by using “Up/Down” key.
- Sound: Acoustic signal strength monitoring
- Peak Holder: Displayed Measuring level is changed when new measuring level is higher than previous measured value.
- Normal: Displayed Measuring level from input terminal. (Blank of Function display)
-26-
c. Move to other selecting function by using “Shift” key or push “Store” key(two times) to store.
5.3.6. Setup Audio subcarrier(fs-fp) band width
To measure Audio level correctly, check the Audio subcarrier(fs-fp) band width required in TV system of each country. (+4.5 MHz, +5.5 MHz, +6.0 MHz, +6.5 MHz)
a. Move to “Audio Subcarrier” selection group by using “Shift” key. “A” will be blinking.
b. Select desired Audio subcarrier(fs-fp)
band width by using “Up”“Down” key. A: +4.5MHz, B: +5.5MHz, C: +6.0MHz, D: +6.5MHz
a. Move to other selecting function by using “Shift” key or push “Store” key(two times) to store
5.3.7. Unit Selection
The units of level(dBuV ) and unit of voltage (VDC/VAC) can be selected for using desired unit.
a. Move to “Unit” selection group by using “Shift” key. Unit group will be blinking.
b. Select desired unit by using “Up” “Down” key. (dBuV, VDC)
c. Move to other selecting function by using "Shift” key.
** When the “VDC” is selected, the voltage value from cable will be measured. VDC and VAC will be selected automatically according to input voltage.
5.3.8. Change of Channel Number
a. Move to “Ch” selection by using “Shift” key. “Ch” will be blinking.
-27-
b. Select desired channel by using “Up” “Down” key. (Ch 01…99)
c. Move to other selecting function by using “Shift” key or push “Store” key(two times) to store.
5.3.9. Storing of new channel with changed setting
After setting each function and measuring level, the selected conditions can be stored in desired Channel from 01 to 99.
a. Set up all required conditions (Frequency, Function, Audio Subcarier, unit) according to the set-up procedures from 6.3.3 to 6.3.7.
b. Select desired channel number to store. (Refer to 6.3.8)
c. Store Channel by using “Store” Key(two times).
d. To store other new channels, proceed from “a” to “c”.
** All of channels are set to initial conditions before shipment. So it should be set and stored for the requirements of customer.
5.3.10. Recalling of stored Channel To measure input level with conditions of stored channel
a. Press “Call” key to select desired channel. The “Ch” will be blinking.
b. Select desired channel by using “UP”, “DOWN” key.
c. Press “Call” key again to compromise selected channel.
-28-
5.3.11. Indicating the level of internal battery ( )
The level of internal battery is displayed on “Battery indicator”. Refer to following table for the status of battery.
Battery sign of Indicator Time for use
Three bars of
indicator
Two bars of
indicator
One bar of indicator Blinking Indicator
Auto Power off with beep sound
5.4. Level Measurement Procedure
There are two ways to measure input level.
5.4.1. Measure with stored channel and conditions
a. Select desired channel by using “Call”, “Up/Downkey.
b. Connect Input cable to Input terminal from Cable TV and VHF/UHF-TV­ Systems
c. Read “The value of input level” on Display.
5.4.2. Measure by setting the conditions
a. Select desired frequency to measure by using “Shift”, “Up/Down” Key. Refer to “6.3.3 Change of Frequency”. Select the desired conditions(Function, Unit) by using “Shift”, “Up/Down” Key. Refer to “6.3.4 to 6.3.6”.
b. Push “Store” key one time to hold measuring conditions momently.
c. Read “The value of video level” on Display. d. Return to previous measuring condition by pushing “Call”
key(two times).
-29-
Approx. 3 hrs.
Approx. 1,5 hrs.
Approx. 30 min.
Need to charge
5.4.3. Measurement of Audio level of selected channel
The Audio level can be measured and displayed as follow;
a. Move to “Video/Audio” selection by using “Shift” key. “Video” will be blinking. b. Select “Audio” function by using “Up/Down” key. c. Push “Store” key one time to hold measuring conditions momently. d. Read “The value of Audio level” on Display. e. Return to previous measuring condition by pushing “Call” key(two times).
NOTE: “Audio” function cannot be stored in channel memory. The default setting of level measurement in each channel is “Video”. Even though “Audio” is selected, it will be stored to “Video” automatically.
5.4.4. Measurement of Voltage from Cable line
The value of voltage from cable line can be measured as follows; a. Select Unit group by using “Shift” key. b. Select “VDC” by using “Up,Down” Key. c. Push “Store” key one time to hold measuring conditions
momently.
d. Read Input voltage from cable line.
(VDC and VAC will be selected automatically according to input voltage.)
e. Return to previous measuring condition by pushing “Call” key(two times).
NOTE: “Store” Key operation The “Store” key can be used for storing the selected information of channel (Frequency, Function, Audio sub-carrier, Unit) and apply changed measuring conditions of selected channel momently without storing.
- To store selected information: Push “Store” two times. This operation can be used to set-up or change measuring con­ ditions of each channel.
- To apply selected condition momently: Push “Store” one time This operation can be used to change measuring methods and units momently during measuring without changing stored conditions.Return to stored measuring condition by pushing “Call” key two times.
-30-
5.5. Additional Functions
5.5.1. Peak Holder ( )
This meter has “Peak Holder function” to support easy installation of antenna system by detecting highest input level. The displayed measuring level is changed when new measuring level is higher than previous measured value. To set this function, see to 6.3.4.
5.5.2. Acoustic signal strength monitoring ( )
This meter has acoustic signal strength monitoring function to support easy installation of antenna system by hearing the strength of input signal. The beef sound with 1kHz is varied according to the value of input level. To set this function, see to 6.3.4.
5.5.3. Last channel and conditions memory
When the meter turns off, the meter can memory last channel and conditions for supporting same conditions with previous measuring. When the power is turning on by pushing “Power” key, the previous channel and conditions are applied again.
5.5.4. Back Light for LCD display
To read the display in dark area, the back light is turning on by pushing “Lamp” button. To turns off back light, push “Lamp” button again.
5.5.5. Auto Power off
When the voltage of internal battery pack is less than proper voltage and the operation of meter is stopped more than 10 minutes, the power is turning off automatically for saving internal power. When the power is turning on by pushing “Power” key, the previous channel and conditions are applied again.
6. Maintenance
6.1. Adjustment and calibration
It is recommendable to regularly adjust and calibrate this meter. Qualified and authorized personnel only should execute performance and procedures. When the calibration or service is required, contact your local service agent.
6.2. Battery charging CAUTION and NOTE that the battery should be fully charged after
first opening the box. The first time charging is important. Always keep the battery level fully charged before and after use. For charging, we recommend you following ways.
-31-
6.2.1. Charging by AC adaptor (Figure 4-1)
The 12V 500mA DC is recommendable for charging. The input power jack could be accepting with center plus (+). Connect adaptor as follows. Charging time is subject to the condition of battery pack.
Fig. 4-1 Charging by AC adaptor
6.2.2. Charging by power from Cigar-Socket of car (Figure 4-2)
The internal battery of this meter can be charged form Cigar-Socket of car. The out voltage of Cigar socket should be higher than 12VDC. Connect the power from Cigar socket as follows. Charging time is subject to the condition of battery pack.
Fig 4-2 Charging by power from Cigar-Socket of car
NOTE: Charge/Discharge instruction * For a new or longtime-not-used battery, you should do the complete charge to Max. and exhaust (use) completely. * Do not leave the battery connected to a charger more than one day. * Battery is gradually wearing out. If the operation time is noticeably shorter than normal, it is time to buy a new battery.
6.3. Cleaning and Decontamination
The instrument can be cleaned with a soft clean cloth to remove any oil, grease or grime. Never use liquid solvents or detergents. If the instrument gets wet for any reason, dry the instrument using low­pressure clean air at less than 25 PSI. Use care and caution around the window cover areas where water or air could enter into the instrument while drying.
-32-
Batteries, which are used up dispose duly. Used up batteries are hazardous and must be given in the for this being supposed collective container.
All rights, also for translation, reprinting and copy of this manual or parts are reserved. Reproduction of all kinds (photocopy, microfilm or other) only by written permission of the publisher.
This manual considers the latest technical knowing. Technical changing which are in the interest of progress reserved.
We herewith confirm, that the units are calibrated by the factory according to the specifications as per the technical specifications. We recommend to calibrate the unit again, after 3 year.
© PeakTech® 08/2002
-33-