Peak NG3000, NG5000, NG5000A, NG3000A User Manual

NG3000-5000 User Manual Rev 1 PN XXXXXXX 16/01/17
NG3000(A) & 5000(A)
User Manual
Contents
Change History 3 How to use this Manual 3 Introduction 4 Warranties and Liabilities 5 Safety Notices 6 Symbols 6 Safety Notice to Users 6 Declaration of Conformity 7 Environmental Declaration 8 Technical Specification 9 Unpacking 13 Installation 14 Generator Environment 14 Removing the generator from the shipping crate 15 Generator Overview 16 General Dimensions 16 Removal of Transit Brackets 17 Wall Mounting 18 Rear Connections 19 Electrical Connection 20 Fuse 20 Start-Up Sequence 21 Normal Operation 22 Unusual Operation 22 Service Requirements 23 Service Schedule 23 Peak Protected 24 Cleaning 25
Page 3
Change History
Rev Comment Name Date
How to use this Manual
This manual is intended for end users and has been written as a reference document where you can skip to the relevant information.
Users can refer to the contents page to find the relevant information.
Please review each of the following sections carefully.
Thank you for selecting Peak Scientific to meet your gas generation needs, and should you require any further assistance or support please do not hesitate to contact Peak Scientific or the Peak Partner from which you purchased your generator.
Page 4
Introduction
The NG range of ultra high purity nitrogen generators have been designed primarily for GC applications and other applications requiring the highest purity nitrogen.
These models provide a source of Nitrogen gas with other features including:
• Available with or without an external compressor
• Contains self-regenerating Carbon Molecular Sieve purification
• The most convenient method of laboratory gas supply
• Gas is supplied on demand so generator works to your schedule
• Remove the hassle and safety concerns with ordering and replacing pressurized cylinder gas
• 12 month comprehensive on-site warranty
Delivering flow rates of 3000cc/min or 5000cc/min, these generators come in two variants, the standard model and the enhanced (A) models which feature an integrated compressor, removing the need for an external air supply to be present in the lab.
To reach their ultra high purity nitrogen output these generators use Pressure Swing Adsorption and Carbon Molecular Sieve. These separation technologies remove oxygen and other impurities in air, delivering hassle-free, ultra high purity nitrogen, on-demand for the lab.
Page 5
Warranties and Liabilities
1. The Company warrants that it has title to the Goods.
2. Subject to the provisions of this clause the Company warrants that the Goods shall comply in all material respects with any specification referred to in the Order Confirmation (as the same may be amended) and shall, subject thereto, be free from defects in material and workmanship for the lesser of a period of twelve months from the date of delivery or thirteen months from the date of dispatch from the factory.
3. Save as provided in this clause and except where the Goods are sold to a person dealing as a consumer (within the meaning of the Unfair Contract Terms Act
1977) all warranties, conditions or other terms implied by statute or common law are hereby expressly excluded save to the extent they may not be lawfully excluded. When the Goods are sold to a consumer within the meaning of the Unfair Contract Terms Act 1977 their statutory rights are not affected by the provisions of this clause.
4. In the event of the Customer making a claim in respect of any defect in terms of clause 2 hereof the Customer must.
1. Reasonably satisfy the Company that the Goods have been properly installed, commissioned, stored, serviced and used and without prejudice to the generality of the foregoing that any defect is not the direct or indirect result of lack of repair and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or incorrect spare parts
2. Allow the company to inspect the Goods and/or any installation and any relevant packaging as and when reasonably required by the Company.
5. Subject to the Company being notified of any defect as is referred to in sub- clause 2 hereof within a reasonable time of it becoming apparent and subject always to the terms of sub-clause 4 hereof, the Company shall, in its option, replace or repair the defective Goods or refund a proportionate part of the Price. The Company shall have no further liability to the Customer (save as mentioned in sub-clause 6 hereof).
6. The Company shall be liable to indemnify the Customer in respect of any claim for death or personal injury to any person in so far as such is attributable to the negligence or breach of duty of the Company or any failure by the Company to comply with the provisions of sub-clause 2 hereof.
7. Save as provided in sub-clause 2 hereof the Company shall not be liable in respect of any claim by the Customer for costs, damages, loss or expenses (whether direct, indirect, consequential or otherwise) or indemnity in any respect howsoever arising including, but not by way of limitation, liability arising in negligence (other than pursuant to clause 6 above) that may be suffered by the Customer or any third party.
WARNING
WARNING
WARNING
WARNING
CAUTION
Page 6
Safety Notices
Peak Scientific Instruments cannot anticipate every possible circumstance which may represent a potential hazard. The warnings detailed within this manual refer to the most likely potential hazards, but by definition cannot be all inclusive. If the user employs an operating procedure, item of equipment or a method of working which is not specifically recommended by Peak Scientific, the user must ensure that the equipment will not be damaged or become hazardous to persons or property.
Symbols
This manual uses the following symbols to highlight specific areas important to the safe and proper use of the generator.
A WARNING notice denotes a hazard. It calls attention to an operating procedure, process or similar, which if not correctly performed or adhered to, could cause personal injury or in the worst case death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood or met.
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, process or similar, which if not correctly performed or adhered to, could cause damage to the generator or the application. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood or met.
Caution, risk of electric shock. Ensure power to the generator has been removed before proceeding.
Safety Notice to Users
These instructions must be read thoroughly and understood before installation and operation of your Peak Generator. Use of the generator in a manner not specified by Peak Scientific MAY impair the SAFETY provided by the equipment.
When handling, operating or carrying out any maintenance, personnel must employ safe engineering practices and observe all relevant local health and safety requirements and regulations. The attention of UK users is drawn to the Health and Safety at Work Act 1974, and the Institute of Electrical Engineers regulations.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment maybe impaired.
Page 7
Declaration of Conformity
We Peak Scientific Instruments Ltd.
Of Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE
Declare that:
Equipment: Nitrogen Generator
Models: NG*000(A) Series
* Denotes any numeric value.
(A) Denotes compressor based model.
To which this declaration relates, is in conformity with the applicable EC directives, harmonized standards, and other normative requirements.
• Low Voltage Directive 2014/35/EU
EN 61010-1: 2010 Electrical Equipment for measurement, control and laboratory use.
• Electromagnetic Compatibility Directive 2014/30/EU
EN 61326-1: 2013 Electrical Equipment for measurement, control and laboratory use.
All evaluation, testing and certification issued by:
York EMC Services Ltd
Donibristle Industrial Park
Dunfermline, Fife
KY11 9HZ
Signed: Name: Chris Pugh
Date: 03/02/2014 Position: Engineering & Operations Director
Page 8
Environmental Declaration
We Peak Scientific Instruments Ltd.
Of Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE
Declare that:
Equipment: Nitrogen Generator
Models: NG*000(A) Series
* Denotes any numeric value.
(A) Denotes compressor based model.
Is fully compliant with the following Directives
• 2012/19/EU WEEE (Waste of Electrical and Electronic Equipment)
• 2011/65/EU RoHS 2 (Restriction of Hazardous Substance)
Peak Scientific Instruments Ltd fully complies with its obligations towards the European WEEE (Waste of Electrical and Electronic Equipment) Directive 2012/19/EU. These obligations are being met within the B2B compliance group.
Peak Scientific Instruments Ltd has developed all reasonable ‘due diligence’ controls to ensure that our products comply with the principles and requirements of the European recast RoHS (Restriction of Hazardous Substances) Directive 2011/65/EU. Similar directives in the United States and China, for example, have also been captured within this program.
Where a specific certificate of compliance is required, this can be requested, on a product serial number basis, directly from Peak Scientific Instruments Ltd, by contacting us through our website on www.peakscientific.com
Signed: Name: Chris Pugh
Date: 03/02/2014 Position: Engineering & Operations Director
Page 9
Technical Specification
NG3000
Environment
Minimum Operating Ambient Temperature 5°C (41°F) Maximum Operating Ambient Temperature 25°C (75°F) Maximum Altitude 2000 m Maximum Relative Humidity 80% Non-Condensing Minimum Storage Temperature* 10°C (50°F) Maximum Storage Temperature* 25°C (75°F)
*NOTE – When taken out of storage the Generator should be allowed to acclimatize at room temperature for a minimum of 3 hours before operation.
Inlet Conditions
Minimum Air Pressure 8.2 bar (120 psi) Maximum Air Pressure 8.8 bar (130 psi)
Generator Outlets
Maximum Gas Output Pressure 5.5 bar (80 psi) Maximum Outlet Flow Rate 3000 cc/min (0.10 cfm) Particles <0.01µm Phthalates NONE Suspended Liquids NONE Gas Outlets 1 x ¼” BSPP Start-Up Time For Purity 8 hours
Electrical Requirements
Voltage 230v or 110v Frequency 50/60 Hz Current 0.5 (1.2) A Pollution Degree 2 Insulation Category II
General
Dimensions cm (inches) WxDxH 43 (16.9) x 41 (16.1) x 124 (48.8) Generator Weight Kg (lbs) 77 (170) Shipping Weight Kg (lbs) 107 (236)