User Manual / Installation Guide
2
Note: can choose underside installation, 45° wall installation and bracket installation, bracket installation is the
most convenient way.
DIP Switch Function:
Choose 3 different pulse counting as below:
1-Pulse: detector make the alarm when detected 1 pulse
2-Pulse: detector make the alarm when detected 2 pulse
3-Pulse: detector make the alarm when detected 3 pulse
more pulse counting, the lower performance for sensitivity of capture, but
more pulse counts can reduce fales alarms.
Setting 3 different working modes as below:
Testing Mode: sending the wireless alarm signal when detector had
been triggered, no time interval between two signal sending.
Normal/Saving Mode: every 2.5mins detect one time, every 65mins
sending one wireless monitoring signal to report the status of detector and
battery.
Coding Mode: when detector is on working status, inverse it to send an
address code to alarm control panel
Coding Method: (between detector and wireless alarm control panel)
1. detector on normal mode, place the lithium battery and LED light will flash
few seconds; alarm control panel on wireless coding mode (please refer
alarm control panel user manual), press tamper switch to sending the
wireless signal to alarm control panel, if alarm control panel make the
corresponding indicate sound, it means match code successfully.
2. alarm control panel on manual coding mode, enter the 9 digit address code
to match, this will be a higher probability of coding success.
Change Battery:
when detector sending the wireless signal, LED light flash, it means the low
battery situation, and detector also can sending the low battery alarm indication
to alarm control panel. (CR123A 3.0V Lithium Battery)
Walk Testing on Cover Area:
1. detector on testing mode, pulse counting set as 1, 2 or 3;
2. horizontal movement which triggers detector alarming at the remote of the
detection coverage at the speed of 0.75m/s, the LED light indicator will
flash few seconds;
3. testing in different direction to confirm the two boundaries of the coverage,
ensure the detector is appointed to the central desired area;
4. the centre of detection area should not be towards vertical incline, if can
not obtain an ideal detection area, please adjust the vertical angle to
ensure direction for detector neither high or low;
5. once detection angle is adjusted, walk testing must be performed again;
6. please set detector to normal mode after finished walk testing.
DIP Switch 1 & 2 setting
corresponding working modes:
DIP Switch 3 & 4 setting
corresponding working modes: