Load max
FDC20-12S33 9 – 18 VDC 3.3 VDC 4000mA
1507mA
77 13000uF
FDC20-12S05 9 – 18 VDC 5 VDC 4000mA
2193mA
80 6800uF
FDC20-12S12 9 – 18 VDC 12 VDC 1670mA 2136mA 82 2200uF
FDC20-12S15 9 – 18 VDC 15 VDC 1330mA 2136mA 82 755uF
FDC20-12D05 9 – 18 VDC ± 5 VDC ± 2000mA 2193mA 80 ± 3400uF
FDC20-12D12 9 – 18 VDC ± 12 VDC ± 833mA 2136mA 82 ± 680uF
FDC20-12D15 9 – 18 VDC ± 15 VDC ± 666mA 2136mA 82 ± 450uF
FDC20-12T3312 9 – 18 VDC 3.3 / ± 12 VDC 3000 / ± 300mA 1926mA 78 4700 / ± 220uF
FDC20-12T3315 9 – 18 VDC 3.3 / ± 15 VDC 3000 / ± 250mA 1959mA 78 4700 / ± 220uF
FDC20-12T0512 9 – 18 VDC 5 / ± 12 VDC 2000 / ± 300mA 1885mA 80 4700 / ± 220uF
FDC20-12T0515 9 – 18 VDC 5 / ± 15 VDC 2000 / ± 250mA 1919mA 80 4700 / ± 220uF
FDC20-24S33 (W) 18 – 36 (9 – 36) VDC 3.3 VDC 4000mA 743 (764mA) 78 (76) 13000uF
FDC20-24S05 (W) 18 – 36 (9 – 36) VDC 5 VDC 4000mA 1082 (1111mA) 81 (79) 6800uF
FDC20-24S12 (W) 18 – 36 (9 – 36) VDC 12 VDC 1670mA 1054 (1082mA) 83 (81) 2200uF
FDC20-24S15 (W) 18 – 36 (9 – 36) VDC 15 VDC 1330mA 1054 (1082mA) 83 (81) 755uF
FDC20-24D05 (W) 18 – 36 (9 – 36) VDC ± 5 VDC ± 2000mA 1082 (1111mA) 81 (79) ± 3400uF
FDC20-24D12 (W) 18 – 36 (9 – 36) VDC ± 12 VDC ± 833mA 1054 (1082mA) 83 (81) ± 680uF
FDC20-24D15 (W) 18 – 36 (9 – 36) VDC ± 15 VDC ± 666mA 1041 (1068mA) 84 (82) ± 450uF
FDC20-24T3312 18 – 36 VDC 3.3 / ± 12 VDC 3000 / ± 300mA 950mA 79 4700 / ± 220uF
FDC20-24T3315 18 – 36 VDC 3.3 / ± 15 VDC 3000 / ± 250mA 967mA 79 4700 / ± 220uF
FDC20-24T0512 18 – 36 VDC 5 / ± 12 VDC 2000 / ± 300mA 931mA 81 4700 / ± 220uF
FDC20-24T0515 18 – 36 VDC 5 / ± 15 VDC 2000 / ± 250mA 947mA 81 4700 / ± 220uF
FDC20-48S33 (W) 36 – 75 (18 – 75) VDC 3.3 VDC 4000mA 367 (377mA ) 79 (77) 13000uF
FDC20-48S05 (W) 36 – 75 (18 – 75) VDC 5 VDC 4000mA 543 (548mA) 82 (80) 6800uF
FDC20-48S12 (W) 36 – 75 (18 – 75) VDC 12 VDC 1670mA 527 (541mA) 83 (81) 2200uF
FDC20-48S15 (W) 36 – 75 (18 – 75) VDC 15 VDC 1330mA 527 (541mA) 83 (81) 755uF
FDC20-48D05 (W) 36 – 75 (18 – 75) VDC ± 5 VDC ± 2000mA 541 (556mA) 81 (79) ± 3400uF
FDC20-48D12 (W) 36 – 75 (18 – 75) VDC ± 12 VDC ± 833mA 514 (527mA) 85 (83) ± 680uF
FDC20-48D15 (W) 36 – 75 (18 – 75) VDC ± 15 VDC ± 666mA 508 (521mA) 86 (84) ± 450uF
FDC20-48T3312 36 – 75 VDC 3.3 / ± 12 VDC 3000 / ± 300mA 468mA 80 4700 / ± 220uF
FDC20-48T3315 36 – 75 VDC 3.3 / ± 15 VDC 3000 / ± 250mA 477mA 80 4700 / ± 220uF
FDC20-48T0512 36 – 75 VDC 5 / ± 12 VDC 2000 / ± 300mA 459mA 82 4700 / ± 220uF
FDC20-48T0515 36 – 75 VDC 5 / ± 15 VDC 2000 / ± 250mA 467mA 82 4700 / ± 220uF
Note
1. The FDC20 series required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage
these devices, however they may not meet all listed specification.
2. Cross regulation:
Dual output—Asymmetrical load 25% to 100% full load
Triple output – 3.3V / 5V 100% load and one of auxiliary 100% load, other auxiliary load change from 25% to 100% load
3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
4. The ON/OFF control pin voltage is referenced to negative input
5. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environm ent)
6. Heat sink is optional and P/N: 7G-0011A.
Operation temperature range please see curve.
7. Maximum value at nominal input voltage and full load.
8. Typical value at nominal input voltage and full load.
9. Test by minimum Vin and constant resistor load.
10. The FDC20-24D3305 and FDC20-48D3305 are safety approval pending.
50 60 70 80 90 100 -40 -25 0 -10
25
50
75
100
0
AMBIENT TEM PERATUR E (ºC)
OUTPUT POWER (%)
FDC20-48S05 Derating Curve
Nature convection
50 60 70 80 90
100 -40 -25 0 -10
25
50
75
100
0
AMBIENT TEM PERATUR E (ºC)
OUTPUT POWER (%)
FDC20-48S05 Derating Curve
With HEAT-SINK (Note 6)
Nature convection