IMPORTANT WIRING INFORMATION:
Before installing the Battery Back Up System please pay attention to the information given below.
Incorrect Installation will cause the Battery Back Up System to function incorrectly and may result in damage to the Battery Back Up.
CORRECT INSTALLATION METHOD:
INCORRECT INSTALLATION METHOD:
Note:
Never add an additional loop from the Battery Back Up system into the mains power.
Never add an additional loop from the P D Technology Control Unit into the mains
power.
Both of the above will cause serious damage to the Battery Back Up System.
If you are unsure about how to wire the Battery Back Up System contact P D Technology Ltd before beginning your installation.
MAINS POWER BATTERY BACK UP
P D TECHNOLOGY
CONTROL UNIT
MAINS POWER BATTERY BACK UP
P D TECHNOLOGY
CONTROL UNIT
www.garagedoorsonline.co.uk
01926 463888
www.garagedoorsonline.co.uk
www.garagedoorsonline.co.uk
01926 463888
www.garagedoorsonline.co.uk
1
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS 2 - 3
Front View of PDT Power Series 4 Rear View of PDT Power Series 5
WHAT’S INCLUDED 6 INSTALLATION 7 CONTROLS AND INDICATORS 8
ON/OFF/Alarm Silence Button 8 Status Indicators: Mains, Battery, Fault, Standby 9
Mains Indicator (Green/Amber) 9 Battery Indicator (Green/Amber) 9 Fault Indicator (Red/Green) 9 Standby Indicator (Red) 9 Location and Status of Indicators 9
MODES OF OPERATION 10
Normal Mode 10 Buck/Boost Mode 10 Battery Mode 11 Standby Mode 12 Dip Switch Modes 13 Key Switch Inputs 14
MAINTENANCE 14
Cleaning the UPS 14 Maintaining Batteries 14 Battery Replacement 15
Battery Replacement Procedure 15
TROUBLESHOOTING 16
Guide to Status Indicators 16 Troubleshooting Chart 17 Technical Specifications 18
www.garagedoorsonline.co.uk
01926 463888
www.garagedoorsonline.co.uk
www.garagedoorsonline.co.uk
01926 463888
www.garagedoorsonline.co.uk
2
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important safety instructions that should be followed during the installation and maintenance of the Uninterruptible Power System (UPS) and its batteries. Please read this manual thoroughly before attempting to install or operate this UPS.
Read all safety, installation, and operating instructions before operating the UPS. Adhere to all warnings on the unit and in this manual. Follow all operating and user instructions.
This equipment can be installed and operated by individuals without previous training.
WARNING: PROTECT AGAINST UNEXPECTED OPERATION
ISOLATE FROM MAINS AND DISCONNECT ALL CONNECTOR INPUTS AND OUTPUTS BEOFRE CARRYING OUT ANY MAINTENANCE
The unit can automatically power up the output sockets without warning even if the mains is disconnected following key fob radio transmissions, key switch input or mains check. Disconnect the internal battery prior to removing the front cover to connect a key switch or change the dip switch settings.
WARNING
SAFETY PRECAUTIONS
There are no user-serviceable parts inside this UPS except the internal
battery pack. Refer all UPS service to qualified service personnel. Do not attempt to service this product yourself.
Output receptacles on the UPS are electrically live if the UPS is switched on,
even if the UPS is not plugged into a Mains supply. The ON/OFF button on the UPS does not electrically isolate the internal parts. Some components are live even when Mains power is disconnected. To isolate the UPS, switch off the UPS first, then unplug the mains input and output connectors to the load.
Opening or removing the cover may expose you to lethal voltages within this
unit even when it is apparently not operating and the input wiring is disconnected from the electrical source.
Observe all CAUTION and WARNING statements in this manual and on the
unit. Failure to do so may result in serious injury or death.
Never work alone.
CAUTION
Although your UPS has been designed and manufactured to assure personal safety, improper use may result in electrical shock or fire. To ensure safety, please observe the following rules:
Turn off and unplug your UPS before cleaning. Do not use liquid or aerosol
cleaners. A dry cloth is recommended to remove dust from the surface of your UPS.
Do not install or operate your UPS in or near water.
Do not place your UPS on an unstable cart, stand or table.
Do not place your UPS in direct sunlight or near heat emitting sources.
Never block or insert any objects into the ventilation holes or other openings
of the UPS. Keep all vents free of dust accumulation that could restrict airflow.
Do not place the UPS power cord in any area where it may be damaged by
heavy objects.
Placing magnetic storage on the top of the UPS may result in data corruption.
www.garagedoorsonline.co.uk
01926 463888
www.garagedoorsonline.co.uk
www.garagedoorsonline.co.uk
01926 463888
www.garagedoorsonline.co.uk
3
CAUTION
BATTERY HANDLING PRECAUTIONS
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and required precautions. Keep unauthorized personnel away from the batteries.
A battery can present a risk of electrical shock and high short-circuit current. The following precautions should be observed when working on batteries:
Remove watches, rings, and other metal objects.
Use tools with insulated handles.
Do not dispose of battery or batteries in a fire. The battery may explode.
Do not open or mutilate the battery or batteries. Released electrolyte is
harmful to skin and eyes. It may be toxic.
When replacing the battery, use same number and type of battery as the
suitable recommended type of battery listed in specification table in back of this manual.
Handle, transport and recycle batteries in accordance with local regulations.
WARNING
If your unit demonstrates any of the following conditions, turn off and unplug your unit from the outlet and contact P D Technology Ltd
The power cord is damaged.
Liquid has been spilled on the unit.
The circuit breaker or fuse opens frequently.
The unit does not operate in accordance with the user manual.
Electromagnetic Compatibility – The PDT Battery Back Up complies with the requirements of the EMC Directive 89/336/EEC and the published technical standards. Continued compliance requires installation in accordance with these instructions and use of PDT approved accessories only.
Environmental – Operate the unit in an indoor environment only. Install in a clean environment, free from conductive contaminates, moisture, flammable liquids, gases, or corrosive substances.
www.garagedoorsonline.co.uk
01926 463888
www.garagedoorsonline.co.uk
www.garagedoorsonline.co.uk
01926 463888
www.garagedoorsonline.co.uk
4
FRONT VIEW OF BATTERY BACK UP
POWER
ON/OFF Alarm Silence*
MAINS
INDICATOR* (Green/Amber)
FAULT
INDICATOR* (Red/Green)
BATTERY
INDICATOR* (Green/Amber)
* For details s
ee
controls and indicators
section
STANDBY
MODE LED* (Red)
SHIPPING
BUTTON * (Concealed)
www.garagedoorsonline.co.uk
01926 463888
www.garagedoorsonline.co.uk
www.garagedoorsonline.co.uk
01926 463888
www.garagedoorsonline.co.uk
Loading...
+ 14 hidden pages