PDR Mounts fcp50 User Manual

Mounts by
A division of David Engineering & Mfg. Inc.
M odel
FCP-50 FALSE CEILING PLATE KIT
Thank you for purchasing this PDR product To ensure the correct usage, please read and follow the instruction
All PDR mounts and adapters carry a limited lifetime warranty against defects in material and workmanship. We are not liable for improper installation that results in damage
To ensure customer safety, be sure to decide the installation location so that the strength is sufficient to withstand the weight of both the projector and the false ceiling plate kit (FCP). Always use at least two persons for all installations. Fully tighten all of the mounting screws as specified in the installation instructions.
manual thoroughly. Please store the instructions in a safe place
to mounts, adapters or presentation equipment.
Special techniques are necessary for installation of the panel display mount.
Do not attempt to perform this work by yourself. Request an installation specialist to install this unit. Manufacturer assumes absolutely no responsibility for injuries and damages that may occur due to improper installation and handling.
for future reference.
Suitable for mounting above 2’ x 2’ or 2’ x 4’ ceiling tiles
1
WARNINGS AND PRECAUTIONS
The ceiling structure must be capable of supporting at least 5 times the weight of the projector and the FCP kit. Check with a qualified installer to verify the ceiling’s integrity to support the projector and FCP kit per instructions. Failure to do so could cause serious injury.
Note: Incorrect installation can cause the
INSTALLATION ON A FALSE CEILING
Always install so that the load is carried by the ceiling support structure (not the false ceiling ) thru the guide wires and quick locks supplied. The ceiling structure must be able to support at least 4 times the weight of the projector and the FCP kit.
Avoid installing in locations where the temperature and humidity are excessively high, and where contact with any
water is possible. These can result in fire or electric shock.
Do not install close to an air conditioner intake or outlet. Do oily smoke or tobacco smoke. Fire could result. Do not block the ventilation holes. Leave sufficient clearance in regard to the surroundings to avoid blocking the ventilation.. The internal temperature could elevate and possibly result in fire. Install theprojector (4") or more away from surroundings.
Do not install in locations where there is excessive vibration or impact. Injury and damage could result from the panel display falling.
Do not install where there is direct sunlight or other strong
Total load of the
MAXIMUM WEIGHT - 50 Lbs. ( 22 Kg.)
WARNING
projector to fall and cause injury.
projector + FCP-50
CAUTION
not install in locations where there are excessive amounts of dust,
light. Strong light could result in eye fatigue during usage.
Use the specified bolts and screws in the specified places and tighten firmly. Failure to do this could cause injury if the projector falls.
Do not alter any of the parts. Do not use broken parts. This
Always use at least two people to perform the installation work. Injury could result from dropping heavy objects.
Caution: installation of the unit is to be carried out by qualified technicians only. Install in an appropriate location by checking the ceiling structure and durability for safety and accident prevention
Rev 031208
WARNING
could result with injury due to the projector falling.
2
SPECIFICATIONS
4.18” min
.94”
4.08” min
12.08” max
24.90”
CUTOUTS FOR
ELECTRICAL FLUSH MOUNT BOX
8.35”
1.07”
STANDARD
5
6
4
3
2
9
7
12
8
3