PDC spas Antero, Boulder, Vancouver, Antigua, Columbia Owners & Installation Manual

...
O
WNERS INSTALLATION
ORTABLE SPA HOT TUBS
R
M
EVISED
ANUAL
01/2009
www.pdcspas.com
IMMEDIATELY
UPON DELIVERY
REGISTER YOUR HOT TUB
ON THE PDC SPAS WEB SITE
WWW.PDCSPAS.COM
THIS INFORMATION IS
VERY IMPORTANT
TO ENSURE
WARRANTY COVERAGE
AND
RECEIVE INFORMATION
FOR POSSIBLE
PRODUCT UPDATES.
PDC S
C
ONGRATULATIONS ON CHOOSING A QUALITY
PAS OWNER’S MANUAL
PDC SPA
FOR YOUR BACKYARD RELAXATION
!
P
LEASE READ THE OWNER’S MANUAL COMPLETELY BEFORE INSTALLING AND USING YOUR NEW SPA OF THIS MANUAL IS TO PROVIDE YOU WITH SAFETY, OPERATIONAL AND INSTALLATION INFORMATION WHICH WILL ALLOW YOU THE FULLEST ENJOYMENT OF THIS FINE PRODUCT
.
. THE
PURPOSE
AT
THE TIME OF PRINTING, THIS MANUAL WAS DEEMED AS ACCURATE AS POSSIBLE RIGHT TO CHANGE PRODUCT IN AN EFFORT TO ENHANCE AND IMPROVE, WITHOUT PRIOR NOTICE ANY OF THESE POSSIBLE CHANGES, LOG ON TO WWW.PDCSPAS.COM, REFERRING TO THE CUSTOMER CARE SECTION OR CONTACT YOUR RETAILER DIRECTLY
.
. PDC S
PAS RESERVES THE
. TO BE
AWARE OF
O
WNERSHIP INFORMATION
N
AME
___________________________________________________
A
DDRESS
___________________________________________________ ___________________________________________________ ___________________________________________________ I
NSTALLATION DATE
____ / ____ / ____
,
M
ODEL NAME
S
ERIAL
# _________________________
R
ETAILER NAME
R
ETAILER PHONE NUMBER
S
ERVICE TECHNICIAN CONTACT INFO
_____________________
_____________________________
_____________________
___________________________
___________________________________________________
S
ERIAL
# L
OCATION
THE
SERIAL NUMBER CAN BE FOUND ON THE INSIDE OF THE FILTER HOUSING
ON THE SPA LIP FILTER COVER TO REVEAL THE SILVER SERIAL NUMBER PLATE
FOR AT S
BEHIND CABINET PANEL ON FILTER HOUSING CANISTER
.
SIMPLY REMOVE THE PLASTIC
.
ERIES UNITS, SERIAL NUMBER PLATE IS
SAVE THIS MANUAL FOR EASY FUTURE REFERENCE !
.
PDC S
PAS
, P
LASTIC DEVELOPMENT COMPANY
TEL
. 570-323-3060
, INC., 75 P
WWW.PDCSPAS.COM
ALMER INDUSTRIAL ROAD
FAX
570-323-8485
, W
ILLIAMSPORT
, PA 17701 USA
T
ABLE OF CONTENTS
I
MPORTANT SAFETY INSTRUCTIONS
W
ARNINGS
SPA USE L
L
ABELS
OCATION AND REFERENCE
SPA P
ARTS IDENTIFICATION
SPA P S
ART TERMINOLOGY AND DESCRIPTION
UPPORT EQUIPMENT TERMINOLOGY AND DESCRIPTION
SE S
ERIES SPAS SPECIFICATIONS
LX S
ERIES SPAS SPECIFICATIONS
AT S
ERIES SPAS SPECIFICATIONS
SPA I
NSTALLATION
G E I
W
W
E E
I
NITIAL START-UP
G
SPA L
OCATION CONSIDERATIONS
ENERAL LOCATION CONSIDERATIONS
QUIPMENT LOCATION
NSTALLING THE THERMAL COVER
IRING INSTALLATION
IRING RECOMMENDATIONS
U.S. –S
TATE-SIDE GUIDELINES
XPORT, IN.XM CE PLATFORM XPORT, IN.XE
ENERAL
O
PERATION SYSTEMS
IN.K 600 C IN.K 400 C
W
ATER CHEMISTRY GUIDELINES
M
AINTENANCE RECOMMENDATIONS
W
INTERIZING YOUR HOT TUB
T
ROUBLESHOOTING
R
ECORDS OF SPA CARE
, I
NSTRUCTIONS FOR ALL SPA MODELS
7
10-15
16-24 24-27
, I
NDOORS AND OUTDOORS
35, 36
CE P
LATFORM
37
G
UIDELINES
38
ONTROL ONTROL
, LX S
ERIES SPAS
, SE, AT S
39,40
ERIES SPAS
41, 42
43, 45
45, 46
47
48
49
1-6
8
9
28, 29 30 31 32
33 34
P
LASTIC DEVELOPMENT COMPANY
75 P
ALMER INDUSTRIAL ROAD
W
ILLIAMSPORT
570-323-3060
WWW.PDCSPAS.COM
, PA 17701 USA
TEL
570-323-8485
, INC.
FAX
S
AFETY INSTRUCTIONS
YOU
NOW OWN A HIGH QUALITY
RELAXATION
YOUR SPA AND ENJOY IT WITH SAFETY IN MIND
THOROUGHLY AND UNDERSTAND ALL OF THE SAFETY PRECAUTIONS
WITHIN THESE GUIDELINES ASSURES YEARS OF FUN AND RELAXATION GAINED FROM
. IT IS OF
1
PDC SPA
PRIME IMPORTANCE THAT YOU UNDERSTAND THE OPERATION OF
ADDING A
PDC SPA TO
BUILT FOR YEARS OF ENJOYMENT AND
. YOU
SHOULD READ THIS MANUAL
. U
SING YOUR SPA
YOUR LIFESTYLE
.
WARNING
T
HIS UNIT IS A PROFESSIONAL-GRADE PRODUCT
A
KNOWLEDGE OF CONSTRUCTION TECHNIQUES
PLUMBING AND ELECTRICAL INSTALLATION ACCORDING
TO CODES ARE REQUIRED FOR PROPER INSTALLATION AND
USER SATISFACTION
A LICENSED CONTRACTOR PERFORM THE INSTALLATION
W
ARRANTY IS VOIDED FOR IMPROPER
I
NSTALLATION RELATED ISSUES
. IT IS
RECOMMENDED THAT
.
SAVE THESE INSTRUCTIONS
I
NCLUDED WITH THIS MANUAL IS A SAFETY SIGN THAT IS TO BE POSTED NEAR THE SPA WHERE ALL OCCUPANTS CAN EASILY READ GUEST’S PROTECTION, SAFETY AND TO ASSURE THEIR SPA ENJOYMENT POINT OUT THE LOCATION OF THE SIGN AND INDICATE THE IMPORTANCE OF THE PRECAUTIONS
A
DHERE THE SIGN WITH SCREWS OR ANOTHER MANNER OF PERMANENT ADHESION
S
HOULD YOU REQUIRE ADDITIONAL COPIES OR REPLACEMENTS, SIMPLY CONTACT THE
FACTORY DIRECTLY OR YOUR NEAREST RETAILER
. T
HIS SIGN IS INTENDED FOR YOU AND YOUR
.
. ,
.
. T
AKE THE TIME TO
.
.
2
S
AFETY INSTRUCTIONS
READ AND FOLLOW ALL IMPORTANT SAFETY INSTRUCTIONS
W
HEN INSTALLING AND USING THIS EQUIPMENT BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE TAKEN TO
REDUCE THE RISK OF ELECTRICAL SHOCK, TO ENSURE SAFE USAGE, AND TO SAFEGUARD THE USER’S HEALTH
.
READ AND FOLLOW
ALL INSTRUCTIONS!!
T
HIS UNIT IS A PROFESSIONAL-GRADE PRODUCT
. A
KNOWLEDGE OF CONSTRUCTION TECHNIQUES, PLUMBING AND ELECTRICAL INSTALLATION ACCORDING TO CODES ARE REQUIRED FOR PROPER INSTALLATION AND USER SATISFACTION THAT A LICENSED CONTRACTOR PERFORM THE INSTALLATION FOR IMPROPER INSTALLATION RELATED ISSUES
.
. IT IS
. W
RECOMMENDED
ARRANTY IS VOIDED
IT IS
THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT ALL USERS OF THE SPA ARE ADEQUATELY
INFORMED OF ALL PRECAUTIONS
.
USE
THE SPA ONLY AS DESCRIBED IN THIS MANUAL
THE SPA IN A COMMERCIAL OR RENTAL SETTING
. THE
SPA IS INTENDED FOR HOME USE ONLY
. ALL
WARRANTIES WILL BE VOIDED
. DO
.
GROUND ALL METAL ELECTRICAL EQUIPMENT
A
GREEN COLORED TERMINAL OR A TERMINAL MARKED INSIDE THE SUPPLY TERMINAL BOX OR COMPARTMENT GROUNDING MEANS PROVIDED IN THE ELECTRIC SUPPLY SERVICE PANEL, USING A CONTINUOUS COPPER WIRE EQUIVALENT IN SIZE TO THE CIRCUIT CONDUCTORS SUPPLYING THIS EQUIPMENT
*
ACCORDING TO, BUT NOT LIMITED TO
AT
ALL
ALL
LEAST TWO LUGS MARKED INSIDE OF THE SUPPLY TERMINAL BOX OR COMPARTMENT GRID (HOUSEHOLD GROUND) IN THE AREA OF THE SPA TO THESE TERMINALS, USING AN INSULATED OR BARE COPPER CONDUCTOR NOT SMALLER THAN NO
FIELD-INSTALLED METAL COMPONENTS SUCH AS RAILS, LADDERS, DRAINS OR SIMILAR HARDWARE LOCATED WITHIN WITH COPPER CONDUCTORS NOT SMALLER THAN NO
METAL SURFACES WITHIN
5
FEET OF THE SPA OR HOT TUB MUST BE BONDED TO THE EQUIPMENT GROUNDING BUS
: NEC, NFPA 70, S
“B
ONDING LUGS” ARE PROVIDED ON THE EXTERNAL SURFACE OR ON THE
5
FEET OF THE SPA MUST BE BONDED TO THE HOME BONDING GRID
ECTION
G, GR, G
. T
HIS TERMINAL MUST BE CONNECTED TO THE
680.40, UL 1563.
. C
ONNECT THE LOCAL COMMON BONDING
. 6 AWG.
. 6 AWG.
ROUND, OR GROUNDING
.
, IS
LOCATED
GROUND FAULT CIRCUIT INTERRUPTER PROTECTION (OR EQUIVALENT; RCD, FOR EXPORT INSTALLS)
ALL PDC S PROTECTION IS REQUIRED. ALL
GROUND FAULT CIRCUIT INTERRUPTER GROUND FAULT CIRCUIT INTERRUPTER TYPE CIRCUIT BREAKER IN THE HOME PANEL BOX BY A LICENSED ELECTRICIAN WHEN MAKING WIRE CONNECTION TO THE SPA SUPPORT PACK EQUIPMENT
PAS ARE PERMANENTLY INSTALLED UNITS
SPA EQUIPMENT SYSTEMS MUST BE PROTECTED BY A CLASS A
(GFCI) OR
EQUIVALENT
.
. GROUND FAULT CIRCUIT INTERRUPTER
; RCD,
(NOT SUPPLIED)
FOR EXPORT INSTALLS
MUST BE INSTALLED
. A
DANGER: RISK OF ELECTRICAL SHOCK:
I
NSTALL THE SPA AT LEAST FIVE FEET
G
ROUND FAULT CIRCUIT INTERRUPTER PROTECTION OF THE HOME POWER SUPPLY TO THE SPA IS
NECESSARY
DO
WITHIN FIVE FEET FROM THE SPA
. Y
OUR ELECTRICIAN SHOULD EXPLAIN HOW IT WORKS
NOT PERMIT ANY ELECTRIC APPLIANCE, SUCH AS A LIGHT, TELEPHONE, RADIO OR TELEVISION
(1.52 M) OF A
. W
ATER IS A CONDUCTOR OF ELECTRICITY
SPA
(1.52 M)
. K
EEP ELECTRICAL APPLIANCES AND EXTENSION CORDS AWAY
FROM ALL UNGROUNDED (UNBOUNDED) METAL SURFACES
. (SEE
SPA MAINTENANCE
.
)
NOT USE
.
,
.
3
S
AFETY INSTRUCTIONS
DANGER: RISK OF ACCIDENTAL DROWNING.
E
XTREME CAUTION MUST BE EXERCISED TO PREVENT UNAUTHORIZED ACCESS BY CHILDREN
ACCIDENTS, ENSURE THAT CHILDREN CANNOT USE A SPA UNLESS THEY ARE SUPERVISED AT ALL TIMES
. TO
DANGER: TO REDUCE THE RISK OF DROWNING:
1. N
2. C
3. K
EVER USE THE SPA ALONE HILDREN SHOULD NOT USE THE SPA UNLESS THEY ARE SUPERVISED BY AN ADULT EEP PETS AWAY FROM THE SPA AT ALL TIMES
.
.
4. ALWAYS REPLACE AND LOCK THE SPA COVER WHEN THE SPA IS NOT IN USE.
DANGER: TO REDUCE THE RISK OF DROWNING
P
ROLONGED IMMERSION IN THE SPA MAY CAUSE HYPERTHERMIA EFFECTS OF HYPERTHERMIA MAY BE DESCRIBED AS FOLLOWS INTERNAL TEMPERATURE OF THE BODY REACHES A LEVEL SEVERAL DEGREES ABOVE THE NORMAL BODY TEMPERATURE OF INTERNAL TEMPERATURE OF THE BODY, DIZZINESS, LETHARGY, DROWSINESS, AND FAINTING EFFECTS OF HYPERTHERMIA INCLUDE
1. F
2. F
3. U
4. F
5. P
6. U
AILURE TO PERCEIVE HEAT AILURE TO RECOGNIZE THE NEED TO EXIT THE SPA
NAWARENESS OF IMPENDING HAZARD ETAL DAMAGE IN PREGNANT WOMEN HYSICAL INABILITY TO EXIT THE SPA
NCONSCIOUSNESS RESULTING IN THE DANGER OF DROWNING
98.6 °F (37°C). THE :
SYMPTOMS OF HYPERTHERMIA INCLUDE AN INCREASE IN THE
. THE
CAUSES, SYMPTOMS AND
: H
YPERTHERMIA OCCURS WHEN THE
. THE
DANGER: RISK OF INJURY
DO
NOT REMOVE THE SUCTION FITTINGS SPECIFIC WATER FLOW CREATED BY THE PUMP FITTING OR THE PUMP, BE SURE THAT THE FLOW RATES ARE COMPATIBLE THE SUCTION FITTING IS BROKEN OR MISSING LESS THAN THE FLOW RATE MARKED ON THE ORIGINAL SUCTION FITTING
. THE
SUCTION FITTING IN THIS SPA IS SIZED TO MATCH THE
. S
HOULD THE NEED ARISE TO REPLACE THE SUCTION
. N
EVER REPLACE A SUCTION FITTING WITH ONE RATED
. N
EVER OPERATE THE SPA IF
.
DANGER: RISK OF ACCIDENTAL DROWNING
K
EEP HAIR AND BODY PARTS AWAY FROM THE SUCTION GUARD FREELY IN THE WATER; LONG HAIR SHOULD BE RESTRAINED WITH A BATHING CAP OF DROWNING FROM HAIR OR BODY ENTRAPMENT, INSTALL A SUCTION FITTING (S) WITH A MARKED FLOW RATE IN GALLONS PER MINUTE THAT EQUALS OR EXCEEDS THE FLOW RATE MARKED ON THE EQUIPMENT ASSEMBLY, IF REPLACEMENT OF SUCTION FITTINGS BECOMES NECESSARY
. DO
NOT ALLOW LONG HAIR TO FLOAT
. TO
REDUCE THE RISK
.
WARNING
G
ROUND FAULT CIRCUIT INTERRUPTER PROTECTION SHOULD BE TESTED PRIOR TO EACH USE BY THE HOMEOWNER
TEST” BUTTON ON THE MEDIATELY FAILS TO OPERATE IN THIS MANNER, THERE EXISTS A POSSIBILITY OF ELECTRICAL SHOCK TESTING APPLIES FOR EXPORT PROTECTION DEVICES, I.E
D
ISCONTINUE SPA OPERATION BY DISCONNECTING THE POWER SOURCE AND NOTIFY A QUALIFIED ELEC-
TRICIAN FOR IDENTIFICATION AND CORRECTION OF THE PROBLEM
. NOW
GFCI
RESET THE
CIRCUIT BREAKER AT THE PANEL BOX
GFCI. THE
SPA SHOULD RETURN TO NORMAL OPERATION
(GFCI) OR
. W
. RCD.
EQUIVELANT
ITH THE SPA IN OPERATION, PUSH THE
. THE
; RCD,
SPA SHOULD SHUT DOWN IM-
FOR THE SPA
. IF
THE
. A
PPROVED
GFCI
.
AVOID
.
4
S
AFETY INSTRUCTIONS
WARNING
TO
REDUCE THE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE THIS PRODUCT UNLESS THEY ARE
CLOSELY SUPERVISED AT ALL TIMES
.
WARNING: TO REDUCE THE RISK OF INJURY
THE
E
B
P
P
E
WATER IN A SPA SHOULD NEVER EXCEED
(38º C )
TEMPERATURES ARE RECOMMENDED FOR EXTENDED USE (EXCEEDING YOUNG CHILDREN
EARLY MONTHS OF PREGNANCY TEMPERATURES TO
THERMOMETER SINCE THE TOLERANCE OF WATER TEMPERATURE REGULATING DEVICES MAY VARY AS MUCH AS
AND
104º F (40° C)
ARE CONSIDERED SAFE FOR A HEALTHY ADULT
.
XCESSIVE WATER TEMPERATURES HAVE A HIGH POTENTIAL FOR CAUSING FETAL DAMAGE DURING THE
. P
REGNANT OR POSSIBLY PREGNANT WOMEN SHOULD LIMIT SPA
100º F (38° C).
EFORE ENTERING A SPA, THE USER SHOULD MEASURE THE WATER TEMPERATURE WITH AN ACCURATE
5º F (3°C).
104ºF (40° C). W
ATER TEMPERATURES BETWEEN
. L
10 TO 15
OWER WATER
MINUTES) AND FOR
THE USE OF ALCOHOL, DRUGS, OR MEDICATION BEFORE OR DURING SPA USE MAY LEAD TO UNCONSICIOUSNESS WITH THE POSSIBILITY OF DROWNING.
ERSONS SUFFERING FROM OBESITY OR WITH A MEDICAL HISTORY OF HEART DISEASE, LOW OR HIGH BLOOD PRESSURE, CIRCULATIORY SYSTEM PROBLEMS, OR DIABETES SHOULD CONSULT A PHYSICIAN BEFORE USING A SPA
ERSONS USING MEDICATION SHOULD CONSULT A PHYSICIAN BEFORE USING A SPA SINCE SOME MEDICATION MAY INDUCE DROWSINESS WHILE OTHER MEDICATION MAY AFFECT HEART RATE, BLOOD PRESSURE, AND CIRCULATION
NTER AND LEAVE SPA SLOWLY AND WITH CAUTION SLIPPERY
.
.
.
. S
URFACES AROUND SPA WILL BE WET AND
WARNING
1. N
2. DO
3. DO
4. R
5. K
6. THE PH
EVER USE THE SPA ALONE
NOT BRING ANY OBJECT INTO THE SPA THAT COULD DAMAGE THE SPA SHELL
NOT SIT ON SPA COVER OR PLACE OBJECTS ON IT; IT IS NOT DESIGNED TO SUPPORT WEIGHT EMOVE ANY WATER OR DEBRIS THAT MAY COLLECT ON THE SPA COVER EEP ALL CHEMICALS AWAY FROM CHILDREN AND PETS
AND CHEMICAL BALANCE OF THE WATER MUST BE MAINTAINED AS EXPLAINED IN THIS MANUAL YOUR WARRANTY
. F
AILURE TO DO SO MAY CAUSE INJURY TO USERS OR DAMAGE TO THE SPA, AND WILL VOID
.
.
.
.
.
WARNING: HEALTH CONSIDERATIONS
THE
I
S
USE OF ALCOHOL, DRUGS, MEDICATION CAN GREATLY INCREASE RISK OF FATAL HYPERTHERMIA
NDIVIDUALS WITH INFECTIONS AND OPEN SORES OR WOUNDS SHOULD NOT USE THE SPA THRIVE IN WARM AND HOT WATER CHEMICAL BALANCE
HOWER BEFORE AND AFTER USING THE SPA BODY OILS THAT COULD CONTAMINATE THE WATER CHEMICALS AND ANY BACTERIA THAT MAY HAVE BEEN IN THE SPA
.
. A
LWAYS KEEP YOUR SPA DISINFECTED AND MAINTAIN THE PROPER
. T
HIS WILL REMOVE ANY DEODORANT, PERSPIRATION, OR
. S
HOWERING AFTER WILL REMOVE ANY RESIDUAL
.
. B
ACTERIA
100° F
.
.
S
AFETY INSTRUCTIONS
5
DO
IF
NOT USE THE SPA IMMEDIATELY AFTER STRENUOUS EXERCISE
YOU FEEL PAIN OR DIZZINESS AT ANY TIME WHILE USING THE SPA, DISCONTINUE USE AND CONTACT A
PHYSICIAN
.
.
WARNING: TO REDUCE THE RISK OF INJURY
IT IS
THE
N
DO
ESPECIALLY IMPORTANT FOR PERSONS OVER THE AGE OF HEALTH PROBLEMS, SUCH AS OBESITY, HEART DISEASE, HIGH BLOOD PRESSURE, CIRCULATORY PROBLEMS, OR DIABETES TO CONSULT THEIR PHYSICIAN BEFORE USING THE SPA
SPA JETS PRODUCE A STREAM OF WATER WITH RELATIVELY HIGH PRESSURE
SURE OF A LOCALIZED AREA OF THE BODY MAY CAUSE BRUISES TO THE SKIN
EVER INSERT ANY OBJECT INTO ANY OPENING
NOT USE BREAKABLE CONTAINERS IN OR NEAR THE SPA
.
.
35 OR
PERSONS WITH PRE-EXISTING
.
. P
.
ROLONGED EXPO-
WARNING: ELECTRICAL CONSIDERATIONS
FOR
THE
CONTROLS OTHER THAN UNDERWATER LIGHTING CIRCUITS RUPTER (OR EQUIVELANT FOR EXPORT INSTALLS TROL AN UNDERWATER LIGHTING FIXTURE
F
AULT CIRCUIT INTERRUPTER SHALL NOT OCCUPY CONDUIT
OTHER CONDUCTORS UNLESS THE ADDITIONAL CONDUCTORS ARE ALSO PROTECTED BY A GROUND
F
AULT CIRCUIT INTERRUPTER (OR EQUIVALENT FOR EXPORT INSTALLS
ELECTRICAL SUPPLY FOR THIS PRODUCT MUST INCLUDE A SUITABLY RATED SWITCH OR CIRCUIT BREAKER TO OPEN ALL UNDERGROUND SUPPLY CONDUCTORS TO COMPLYWITH SECTION
U.S. N
ATIONAL ELECTRIC CODE
TUB OCCUPANT BUT INSTALLED AT LEAST
. THE
DISCONNECTING MEANS MUST BE READILY ACCESSIBLE TO THE
)
MUST BE PROVIDED IF THIS DEVICE IS USED TO CON-
. THE
CONDUCTORS ON THE LOAD SIDE ON THE GROUND
5 FT (1.5 M)
FROM THE SPA WATER
: A G
ROUND FAULT CIRCUIT INTER-
,
BOXES, OR ENCLOSURES CONTAINING
).
.
WARNING: FOR
1. CAUTION - R
2. CAUTION - R
3. DO
4. (
COMPONENTS; AND
WARNING
FOR EXAMPLE CABLE, ADDITIONAL SPEAKERS, HEADPHONES, ADDITIONAL AUDIO/VIDEO
COMPONENTS, ETC
5. T ANSI/NFPA 70.
BE INSTALLED IN ACCORDANCE WITH ARTICLE
6. DO
TO DANGEROUS VOLTAGE OR OTHER RISK OF INJURY SERVICE PERSONNEL
7. W
8. T
ENTERING THE AUDIO/VIDEO COMPARTMENT OR ANY ELECTRICAL EQUIPMENT COMPARTMENT AREA IF THE PROTECTIVE SHIELDS OR BARRIERS ARE SHOWING SIGNS OF DETERIORATION; OR IF THERE ARE SIGNS OF OTHER POTENTIAL DAMAGE TO THE UNIT, TURN OFF THE UNIT AND REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
HIS UNIT SHOULD BE SUBJECTED TO PERIODIC ROUTINE MAINTENANCE (FOR EXAMPLE, ONCE
EVERY
SPAS WITH AUDIO
ISK OF ELECTRIC SHOCK ISK OF ELECTRIC SHOCK
/
VIDEO COMPONENTS
. DO
NOT LEAVE COMPARTMENT DOOR OPEN
. R
EPLACE COMPONENTS ONLY WITH IDENTICAL
,
NOT OPERATE THE AUDIO/VIDEO CONTROLS WHILE INSIDE THE SPA
- P
REVENT ELECTROCUTION
.) TO
THE SYSTEM
HESE UNITS ARE NOT PROVIDED WITH AN OUTDOOR ANTENNAE; WHEN PROVIDED, IT SHOULD
NOT SERVICE THIS PRODUCT YOURSELF AS OPENING OR REMOVING COVERS MAY EXPOSE YOU
.
. DO
NOT CONNECT ANY AUXILIARY COMPONENTS
810 OF
THE
U.S. N
. R
EFER ALL SERVICING TO QUALIFIED
ATIONAL ELECTRICAL CODE
.
.
HEN THE POWER SUPPLY CONNECTION OR POWER SUPPLY CORD(S) ARE DAMAGED; IF WATER IS
.
3
MONTHS) TO MAKE SURE THAT THE UNIT IS OPERATING PROPERLY
.
422-20 OF
.
THE
,
;
6
S
AFETY INSTRUCTIONS
ADDITIONAL SAFETY CONSIDERATIONS
I
FOR
W
DO
I
W
NSTALL THE SPA TO PROVIDE DRAINAGE FOR COMPARTMENTS OF ELECTRICAL COMPONENTS
FLOOR RECESSED SPAS
THE FLOOR
DRAINAGE
MATERIALS
THE SPA SPECIFICATION LISTING
SUPPORT EQUIPMENT PER THE MODEL SPECIFICATIONS
. SPA
EQUIPMENT MUST BE INSTALLED BELOW WATER LEVEL
HEN PLANNING YOUR SPA INSTALLATION SITE, PREPARE FOR THE UNLIKELY EVENT OF RAPID SPA
.
NOT PLACE SPA IN DIRECT SUNLIGHT WHILE UNIT IS EMPTY OR WHEN SEALED IN SHIPPING
. E
XCESSIVE HEAT BUILD MAY CAUSE DAMAGE TO SPA AND VOID WARRANTY
NSTALL SPA SO THAT WATER CAN EASILY BE DRAINED OUT
HEN INSTALLING SPA, ALLOW AMPLE SPACE FOR FUTURE SERVICING, NOTING LOCATION OF ALL
: I
NSTALL TO PERMIT ACCESS FOR SERVICING FROM ABOVE OR BELOW
.
.
.
.
,
LOCATING THE SIDE DRAIN VALVE ON
.
SAVE THESE INSTRUCTIONS
75 P
ALMER INDUSTRIAL ROAD
W
ILLIAMSPORT
570-323-3060
WWW.PDCSPAS.COM
PDC S
PAS
, PA 17701 USA
TEL
570-323-8485
FAX
7
SPA USE L
A
FOR
WEATHER RESISTANT WARNING SIGN HAS BEEN MOUNTED ON THE CABINET SIDE OF YOUR PORTABLE SPA FAMILIAR WITH THE PRECAUTIONS AND EXERCISE SAFETY AND CARE WHILE ENJOYING YOUR SPA PRINTED IN TIONAL LANGUAGES ARE ON THE REVERSE SIDE YOU REQUIRE, EXPOSE THE REVERSE SIDE FOR WARNING IN YOUR NATIVE LANGUAGE
ABELS
C
E
NGLISH AND
ABINET PANEL WARNING SIGN
YOUR REFERRAL AND CONVENIENCE, A
F
RENCH EXPOSED, THREE ADDI-
.
. B
. T
HIS SIGN IS
. S
ECOME
HOULD
E L
WITH THIS MANUAL INTENDED FOR PERMANENT POSTING IN AN AREA NEAR THE SPA VISIBLE TO ALL SPA OCCUPANTS
N
OTIFY THE FACTORY OR YOUR RETAILER SHOULD YOU REQUIRE ADDITIONAL SIGNS OR REPLACEMENTS AND
F
G
ERMAN CHOSEN LANGUAGE FOR EASY VIEWING
NCLOSED WARNING SIGN FOR POSTING
OCATE THE WEATHER RESISTANT SIGN ENCLOSED
RENCH VERSIONS ARE ON ONE SIDE
, I
TALIAN ON THE REVERSE
. M
OUNT WITH YOUR
. E
, S
NGLISH
PANISH
.
A
.
,
WARNING:
FOR PERSONAL INJURY OR PROPERTY DAMAGE SUSTAINED BY OR THROUGH THE USE OF THIS PRODUCT
R
EAD ALL INSTRUCTIONS BEFORE USING THE SPA
. PDC S
PAS ASSUMES NO RESPONSIBILITY
SAVE THIS MANUAL, SIGNS, AND INSTRUCTIONS FOR FUTURE REFERENCE.
.
8
SPA P
SPA P
ARTS IDENTIFICATION
ART TERMINOLOGY AND DESCRIPTION
H
YDRO-JETS
S
KIMMER
S
UCTION
AIR C
AIR’
ASSAGE
(
U
LTRA MASSAGE SELECTOR
SPA M
M
OTION GLOW LIGHTING
I
LLUSION LIGHTING
: T
: T
: T
ONTROLS
: T
OOD LIGHT
HESE ARE THE WALL FITTINGS AROUND THE INSIDE PERIMETER OF THE SPA WITH AIR TO PRODUCE LOCALIZED THERAPY, IN A STRAIGHT STREAM, CIRCULAR MOTION OR IN RANDOM PATTERNS FOR UPPER AND LOWER BACK MASSAGE IN THE LOUNGE AND CONTOURED SEATING AREAS
HIS WILL APPEAR AT WATER LEVEL AS A SQUARE INLET OR VERTICAL RECTANGLE INLET SKIMMER TRAPS SURFACE DEBRIS CENTER OF THE SKIMMER FOR BEST RESULTS
HIS IS A CIRCULAR FITTING MOUNTED ON THE VERTICAL WALL OF THE FOOTWELL AND SERVES THE SAME FUNCTION AS THE SKIMMER RETURN WATER TO THE SUPPORT EQUIPMENT
: T
HESE ARE ROUND FITTINGS MOUNTED ON THE LIP OF SPA THAT CONTROL THE AMOUNT OF OUTSIDE AIR MIXED WITH THE INCOMING WATER OF THE HYDRO-JET AIR CONTROLS ON THE SPA LIP THAT CONTROL AIR/ WATER MIX FOR A SEGMENT OF THE JETS
HIS APPEARS AS A NUMBER OF TINY HOLES IN THE SEATING AREA WHEREBY THE BUBBLER
BLOWER) PUSHES AIR THROUGH FOR EXTRA THERAPY ACTION, DELIVERING AN ALL-OVER
MASSAGE WATER ACTION
ENHANCES WATER ACTION THROUGH THOSE JETS BY DECREASING WATER ACTION THROUGH OTHERS
FOR NIGHT TIME SPA ENJOYMENT
AT THE SPASIDE CONTROL PANEL YOUR CHOICE
. S
: U
NDERWATER LOW VOLTAGE LIGHT WITH ADDITIONAL TWO CHANGEABLE COLORED LENSES
: AS AN
POINTS OF LIGHT, ACCENTING THE LIP OF YOUR SPA WITH COLOR OPTIONS OF ROTATING COLORS OR A STATIONARY COLOR OF YOUR SELECTION
.
: L
OCATED ON SPA LIP
TANDARD ON THE
: LOW
VOLTAGE SPA LIGHT, WITH VARYING SHADES OF A COLOR WASH, CONTROLLED
. S
TANDARD WITH THE
OPTION ON THE
. S
TANDARD ON THE
LX S
LX S
. T
HEY MIX WATER
. THE
WATER LEVEL IN THE SPA SHOULD BE KEPT AT THE
.
. IT
WORKS IN CONJUNCTION WITH THE SKIMMER TO
.
. Y
OUR SPA HAS MULTIPLE
LX S
ERIES
.
. T
URN TO ADJUST PUMP POWER TO SELECTED JETS WHICH
ERIES
.
. S
TANDARD WITH THE
. C
HOOSE ROTATION OF COLOR OR STATIONARY COLOR OF
LX S
ERIES, OPTIONAL ON THE
ERIES
, LED
PINPOINT LIGHTS ILLUMINATE WITH UP TO
.
SE S
ERIES SPAS
SE S
.
ERIES SPAS
. THE
.
.
25
U
LTRA MASSAGE SELECTOR
M
AIN CONTROL CENTER
TOP L
OAD FILTER
H
YDRO JETS
S
UCTIONS
S
A
DVANTAGEPACK
(
OPTIONAL
KIMMER
)
AIR C
ONTROLS
L
A
IGHT HOUSING
CRYLIC SPA SHELL
9
S
UPPORT EQUIPMENT IDENTIFICATION
SPA P
ART TERMINOLOGY AND DESCRIPTION
THE
PUMPS, THAT CIRCULATE THE WATER THROUGH THE HYDRO-JETS AND BACK THROUGH THE SUCTIONS; A CARTRIDGE FILTER THAT PHYSICALLY REMOVES DEBRIS FROM THE WATER; AND A BUBBLER (AIR BLOWER) THAT PUSHES AIR THROUGH THE AIR CHANNEL OF THE SPA FOR INCREASED THERAPY EQUIPPED WITH AN ELECTRIC HEATER ROUTED THROUGH THE PUMP, FILTER (USUALLY LOCATED ON THE PRESSURE SIDE OF THE PUMP FOR OPTIMUM FILTRATION OVER BODY MASSAGE IN THE
P
UMP
: Y
THE
PUMP1
F
ILTER
AIR’
ASSAGE
IT IS
H
EATER
O
ZONE
USE
SPA SUPPORT PACK CONTAINS UP TO FIVE MAJOR COMPONENTS: EITHER SINGLE OR DUAL SPEED
. Y
OUR UNIT WILL ALSO BE
. ALL
COMPONENTS ARE OPERATED BY SWITCHING AT SPA SIDE
),
HEATER AND JETS
OUR NEW SPA HAS BEEN EQUIPPED WITH A PUMP FOR HYDROTHERAPY JET ACTION AND WATER FILTRATION ONE OR TWO ADDITIONAL SINGLE SPEED PUMPS THE HIGH SPEED OF A DUAL-SPEED PUMP IS ACTIVATED BY THE
CONTROL FROM SPA TO SPA
EVEN THOUGH TURNING OFF THE PUMP AT THE FILTRATION CYCLE (LOW SPEED CIRCULATE THE SYSTEM AT A TIME WHEN BATHERS ARE EXITING THE SPA, THE PUMP WILL CONTINUE TO OPERATE AT LOW SPEED EVEN THOUGH THE JET BUTTON IS PUSHED UNIT WILL SHUT THE PUMP OFF WHEN PROGRAMMED TO DO SO PRESENT, ARE ACTIVATED BY THE
: Y
: Y
OUR SURES OPTIMUM WATER FILTERING AND EASE OF CLEANING AT SPA SIDE NANCE SECTION OF THIS MANUAL FOR FILTER CARTRIDGE CLEANING AND REPLACEMENT
(AIR B
UBBLER
COMPONENTS
BEHIND A CABINET PANEL INSTALLING
OUR SPA IS EQUIPPED WITH THERMOSTAT CONTROL AT SPA SIDE TEMPERATURE YOU ENJOY MOST, LEAVE THE THERMOSTAT AT THAT SETTING, AND THE SPA WILL AUTOMATICALLY MAINTAIN THE CORRECT TEMPERATURE; READY FOR YOUR ENJOYMENT ANY TIME OF THE DAY TO MAINTAIN TEMPERATURE, THAN TO LET THE TEMPERATURE FALL AND THEN WAIT DURING HEAT-UP TIME BEFORE SOAKING
: ALL
LOWER SPEED (FILTRATION SPEED) IS CONTROLLED BY THIS PROGRAMMABLE ELECTRONIC
PDC
ACTIVATED BY DEPRESSING THE BUBBLER CONTROL AT SPA SIDE
SPAS WITH OZONE OPTION FOR SANITATION SHOULD CIRCULATE THE PROGRAMMABLE ELECTRONIC CONTROL CENTER TO PROGRAM THIS OPERATION
. THE
BUBBLER ACTS AS A SEPARATE COMPONENT AND IS USED FOR A SOFT ALL
LX S
ERIES SPAS
. THE
SPA SUPPORT PACK FEATURES A DUAL-SPEED PUMP AND, ON SOME MODELS
. THE
FILTRATION TIME REQUIRED TO MAINTAIN WARM, CLEAN WATER MAY VARY
. G
ENERALLY, NO LESS THAN SIX HOURS A DAY IS RECOMMENDED
BUTTON CAN ACTIVATE THE PUMP AT FULL SPEED AT ANY TIME FOR HYDROTHERAPY
SPA IS EQUIPPED WITH A TOP-LOAD PRESSURIZED OR SUCTION-SIDE FILTER
): T
HIS EQUIPMENT ACTS INDEPENDENT FROM ALL OTHER SUPPORT EQUIPMENT PACK
. IT
PUSHES OUTSIDE AIR THROUGH THE AIR CHANNEL FOR GENERALIZED MASSAGE
.
. THE D
PUMP1
). FOR
EXAMPLE, IF THE SPA HAS BEEN PROGRAMMED TO
PUMP2 OR PUMP3
. M
AKE NOTE OF THIS LOCATION, ALONG WITH ALL OTHERS, PRIOR TO
ELUXE
GE
CONTROL CENTER OPERATES
PUMP1
BUTTON DOES NOT OVERRIDE THE
. THE
CONTROL
.
CONTROL AT SPA SIDE
SINGLE-SPEED PUMP(S
. R
EVIEW THE MAINTE
. THE
BLOWER IS LOCATED
.
. O
NCE YOU FIND THE
. A
VOID CONSTANT RESETTING OF THE THERMOSTAT; IT IS MORE ECONOMICAL
.
16-24
HOURS DAILY
. W
. THE
. THE
ATER IS
CONTROL
), IF
. T
HIS AS
.
.
.
-
,
.
,
.
SE S
ERIES SPECIFICATIONS
—A
NTERO SPA MODEL
GENERAL rev. 2009 / 01
Seating Capacity 3 Shell Material Acrylic Dimensions (Domestic) 60” (5’) x 84” (7’) x 33” (2’9”) Dimensions (Export) 152 cm. x 213 cm. x 84 cm. Water Capacity 200 Gallons (757 liters) Dry Weight 450 lbs. (204 kg) Skirt Material PermaWood™ or Cedar Water Flow 187 Gallons per Minute
10
WATER SYSTEM** (photo ref.) Water Treatment System Ozone Ready Filter 25 sq. ft. Slide Valves 2 Mega Swirl Jet A 1 Large Euro Jet w/ Eyeball E 26 Mega’ssage Jet G 2 Multi’ssage Jet P 0 Ozone Jet O 2 Diverter Valves V 0 Safety Suction U 1 Mini Skimmer K 1 Air Control I 3 Spa Light L 1 Drain Valve 5 1
SPECIAL FEATURES
Spa Pillows Motion Glow™ Light Stainless Steel Jetting Waterfall Jet WF Waterfall Control Valve C SoundWave™ SE Audio Ozone Water Purification OZ
3 Optional Optional Optional Optional Optional* Optional
K,U, L,O
5
C
HXM
G, A
E
oz
WF
E
E
E
7
6,H
I
1
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak(Continuous) HP 1 4.0 (2.0) HP 4.0 (2.0) HP
Electronics
Electrical Can 6 Gecko XE Series Gecko XM Series Gecko XE Series Voltage 240 240 240 Amperage 40 2x16 / 1x32 / 3x16 2x16 / 1x32 Heater
(heater location for XM can)
Operation System
Main Spa Side Control 7 Gecko 450 Control Gecko 450 Control Secondary Spa Side Control 8 N/A N/A
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
H
HXM
Dimensions are approximate.
4.0 KW 3.8 KW 4.0 KW
SE S
ERIES SPECIFICATIONS
GENERAL rev. 2009 / 01
Seating Capacity 6 Shell Material Acrylic Dimensions (Domestic) 82” (6’10”) sq. x 36” (3’) Dimensions (Export) 210 cm. sq. x 92 cm. Water Capacity 375 Gallons (1,420 liters) Dry Weight 665 lbs (302 kg) Skirt Material PermaWood™ or Cedar Water Flow 428 Gallons per Minute
—B
OULDER SPA MODEL
11
2 1
I
I
WATER SYSTEM** (photo ref)
Water Treatment System Ozone Ready Filter 25 sq. ft.
Slide Valves 4 Mega Swirl Jet A 3 Large Euro Jet w/ Eyeball E 60 Mega’ssage Jet G 6 Ozone Jet O 2 Multissage Jet P 0 Diverter Valves V 0 Safety Suction U 3 Mini Skimmer K 1 Air Control I 4 Spa Light L 1 Drain Valve 5 1
SPECIAL FEATURES
Spa Pillows 3 Motion Glow™ Light Optional
Stainless Steel Jetting Optional Waterfall Jet WF Optional Waterfall Control Valve C Optional SoundWave™ SE Audio Optional* Ozone Water Purification OZ Optional
6H
6
OZ
I
G
A,E
E
I
U
E
E
U
O
A E
K
E
L
WF
5
HXM
6,H
7
OZ
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP Pump #2 peak (continuous) HP 2 6.0 (3.0) HP 6.0 (3.0) HP
Electronics
Electrical Can 6 Gecko XE Series Gecko XM Series Gecko XE Series Voltage 240 240 240 Amperage 40 2x16 / 1x32 / 3x16 2x16 / 1x32 Heater
(heater location for XM can)
Operation System
Main Spa Side Control 7 Gecko 450 Series Gecko 450 Series Secondary Spa Side Control 8 N/A N/A
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
H
HXM
Dimensions are approximate.
4.0 KW 3.8 KW 4.0 KW
SE S
ERIES SPECIFICATIONS
GENERAL rev. 2009 / 01
Seating Capacity 5 Shell Material Acrylic Dimensions (Domestic) 76” (6’4”) sq. x 31” (2’7”) Dimensions (Export) 193 cm. sq. x 79 cm. Water Capacity 275 Gallons (1,041 liters) Dry Weight 530 lbs. (240 kg.) Skirt Material PermaWood™ or Cedar Water Flow 187 Gallons per Minute
WATER SYSTEM** (photo ref)
Water Treatment System Ozone ready Filter 25 sq. ft. Slide Valves 2 Mega Swirl Jet A 2 Large Euro Jet w/ Eyeball E 28 Mega’ssage Jet G 2 Multi’ssage Jet P 0 Ozone Jet O 2 Diverter Valves V 0 Safety Suction U 1 Mini Skimmer K 1 Air Control I 3 Spa Light L 1 Drain Valve 5 1
—C
OLUMBIA
12
SPA M
5
6,H
OZ
1
7
ODEL
HXM
E
G
L
E
I
O
E
E
A
G
I
E
U
K
SPECIAL FEATURES
Spa Pillows 3 Motion Glow™ Light Optional Stainless Steel Jetting Optional Waterfall Jet WF Optional Waterfall Control Valve Optional SoundWave™ SE Audio N/A Ozone Water Purification OZ Optional
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 4.0 (2.0) HP 4.0 (2.0) HP
Electronics
Electrical Can 6 Gecko XE Series Gecko XM Series Gecko XE Series Voltage 240 240 240 Amperage 40 2x16 / 1x32 / 3x16 2x16 / 1x32 Heater
(heater location for XM can)
Operation System
Main Spa Side Control 7 Gecko 450 Series Gecko 450 Series Secondary Spa Side Control 8 N/A N/A
H
HXM
4.0 KW 3.8 KW 4.0 KW
I
WF
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
SE S
ERIES SPECIFICATIONS
GENERAL rev. 2009 / 01
Seating Capacity 8 Shell Material Acrylic Dimensions (Domestic) 82” (6’10”) sq. x 39” (3’3”) Dimensions (Export) 209 cm. sq. x 100 cm. Water Capacity 425 Gallons (1,609 liters) Dry Weight 645 lbs. (293 kg.) Skirt Material PermaWood™ or Cedar Water Flow 428 Gallons per Minute
WATER SYSTEM** (photo ref.)
Water Treatment System Ozone ready Filter 25 sq. ft. Slide Valves 4 Mega Swirl Jet A 6 Large Euro Jet w/ Eyeball E 63 Mega’ssage Jet G 3 Multi’ssage Jet P 0 Ozone Jet O 2 Diverter Valves V 0 Safety Suction U 3 Mini Skimmer K 1 Air Control I 4 Spa Light L 1 Drain Valve 5 1
SPECIAL FEATURES
Spa Pillows 2 Motion Glow™ Light Optional Stainless Steel Jetting Optional Waterfall Jet WF Optional Waterfall Control Valve C Optional SoundWave™ SE Audio Optional* Ozone Water Purification OZ Optional
—D
ENALI
13
SPA M
ODEL
I
2
I
E
A
G
A
E
G
OZ
K
U
6,H
E
U
O,L
C
1
I
U
WF
7
HXM
E
A
E
I
5
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak(Continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP Pump #2 peak(Continuous) HP 2 6.0 (3.0) HP 6.0 (3.0) HP
Electronics
Electrical Can 6 Gecko XE Series Gecko XM Series Gecko XE Series Voltage 240 240 240 Amperage 50 2x16 / 1x32 / 3x16 2x16 / 1x32 Heater
(heater location for XM can)
Operation System
Main Spa Side Control 7 Gecko 450 Series Gecko 450 Series Secondary Spa Side Control 8 N/A N/A
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
H
HXM
Dimensions are approximate.
4.0 KW 3.8 KW 4.0 KW
SE S
ERIES SPECIFICATIONS
GENERAL rev. 2009 / 01
Seating Capacity 7 Shell Material Acrylic Dimensions (Domestic) 94” (7’10”) sq. x 39” (3’3”) Dimensions (Export) 240 cm. sq. x 99 cm. Water Capacity 520 Gallons (1,968 liters) Dry Weight 750 lbs. (340 kg.) Skirt Material PermaWood™ or Cedar Water Flow 428 Gallons per Minute
—E
VEREST
14
SPA M
ODEL
2
WATER SYSTEM** (photo ref.)
Water Treatment System Ozone ready Filter 25 sq. ft. Slide Valves 4 Mega Swirl Jet A 1 Large Euro Jet w/ Eyeball E 63 Mega’ssage Jet G 10 Multi’ssage Jet P 0 Ozone Jet O 2 Diverter Valves V 0 Safety Suction U 3 Mini Skimmer K 1 Air Control I 4 Spa Light L 1 Drain Valve 5 1
SPECIAL FEATURES
Spa Pillows 2 Motion Glow™ Light Optional Stainless Steel Jetting Optional Waterfall Jet WF Optional Waterfall Control Valve Optional SoundWave™ SE Audio Optional* Ozone Water Purification OZ Optional
E A
E
U
G
K
WF
E
E
E E
O L
HXM
E
G
1
6,H
OZ
7
I
5
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP Pump #2 peak (continuous) HP 2 6.0 (3.0) HP 6.0 (3.0) HP
Electronics
Electrical Can 6 Gecko XE Series Gecko XM Series Gecko XE Series Voltage 240 240 240 Amperage 50 2x16 / 1x32 / 3x16 2x16 / 1x32 Heater
(heater location for XM can)
Operation System
Main Spa Side Control 7 Gecko 450 Series Gecko 450 Series Secondary Spa Side Control 8 N/A N/A
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
H
HXM
Dimensions are approximate.
4.0 KW 3.8 KW 4.0 KW
SE S
ERIES SPECIFICATIONS
GENERAL rev. 2009 / 01
Seating Capacity 7 Shell Material Acrylic Dimensions (Domestic) 78” (6’6”) oct. x 37” (3’1”) Dimensions (Export) 201 cm. oct. x 94 cm. Water Capacity 325 Gallons (1,231 liters) Dry Weight 575 lbs. (260 kg.) Skirt Material PermaWood™ or Cedar Water Flow 187 Gallons per Minute
—V
ANCOUVER
15
SPA M
ODEL
WATER SYSTEM** (photo ref.)
Water Treatment System Ozone ready Filter 25 sq. ft. Slide Valves 2 Mega Swirl Jet A 2 Large Euro Jet w/ Eyeball E 19 Mega’ssage Jet G 3 Multi’ssage Jet P 0 Ozone Jet O 2 Diverter Valves V 0 Safety Suction U 1 Mini Skimmer K 1 Air Control I 2 Spa Light L 1 Drain Valve 5 1
SPECIAL FEATURES
Spa Pillows 0 Motion Glow™ Light Optional Stainless Steel Jetting Optional Waterfall Jet WF Optional Waterfall Control Valve C Optional SoundWave™ SE Audio N/A Ozone Water Purification OZ Optional
E,A
E,G
5
E E,G
O
K
L
G
I
OZ
U
WF I
6,H
E
HXM
1
7
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 4.0 (2.0) HP 4.0 (.0) HP
Electronics
Electrical Can 6 Gecko XE Series Gecko XM Series Gecko XE Series Voltage 240 240 240 Amperage 40 2x16 / 1x32 / 3x16 2x16 / 1x32 Heater
(heater location for XM can)
Operation System
Main Spa Side Control 7 Gecko 450 Series Gecko 450 Series Secondary Spa Side Control 8 N/A N/A
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
H
HXM
Dimensions are approximate.
4.0 KW 3.8 KW 4.0 KW
16
LX S
Seating Capacity 8 Shell Material Acrylic Dimensions (Domestic) 82” (6’10”) sq. x 39” (3’3”) Dimensions (Export) 209 cm. sq. x 100 cm. sq. Water Capacity 425 Gallons (1,609 liters) Dry Weight 645 lbs (293 kg) Skirt Material Permawood™ or Cedar Water Flow 510 Gallons per Minute
WATER SYSTEM** (photo ref.)
ERIES SPECIFICATIONS
GENERAL rev. 2009 / 01
Water Treatment System OZ Ozonator Filter 25 sq. ft. Slide Valves 6 Mega Swirl Jet A 5 Large Euro Jet w/ Eyeball E 20 Mega’ssage Jet G 12 Ozone Jet O 2 Multi’ssage Jet P 1 Rotopulse R 2 Shower Head SH 3
—A
NTIGUA SPA MODEL
8
4
G
E
K
AT
P
U
A
A,G
FM, L, O
I
2
G
A,G
WF
V
C
5
H
7
1
oz 6
Aromatherapy AT 1 Foot Jet FM 2 Diverter Valves V 2 Safety Suction U 5 Mini Skimmer K 1 Air Control I 5 Spa Light L 1 Drain Valve 5 1
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP Pump #2 peak (continuous) HP 2 4.0 (2.0) HP 4.0 (2.0) HP Pump #3 peak (continuous) HP 3 4.0 (2.0) HP 4.0 (2.0) HP Air Bubbler 4 1.5 HP 1.5 HP
Electronics
Electrical Can 6 Gecko XM Series Gecko XM Series Voltage 240 240 Amperage 50 2x16 / 1x32 / 3x16 Heater H 4.0 KW 3.8 KW
Operation System
Main Spa Side Control 7 Gecko 600 Series Gecko 600 Series Secondary Spa Side Control 8 Optional (100 Series ) Optional (100 Series)
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
SPECIAL FEATURES
Spa Pillows 2 Motion Glow™ Light Standard Stainless Steel Jetting Optional Waterfall Jet /Control Valve WF, C Standard Illusion Lighting Optional SoundWave™ LX Audio Optional*
Dimensions are approximate.
3
17
LX S
ERIES SPECIFICATIONS
—A
RUBA
GENERAL rev. 2009 / 01
Seating Capacity 5 Shell Material Acrylic Dimensions (Domestic) 86” (7’2”) sq. x 37” (3’1”) Dimensions (Export) 218 cm. sq. x 94 cm. Water Capacity 375 Gallons (1,420 liters) Dry Weight 670 lbs. (304 kg.) Skirt Material Permawood™ or Cedar Water Flow 510 Gallons per Minute
WATER SYSTEM ** (photo ref.)
Water Treatment System OZ Ozonator Filter 25 sq. ft. Slide Valves 6 Mega Swirl Jet A 2 Large Euro Jet w/ Eyeball E 27 Mega’ssage Jet G 9 Ozone Jet O 2
SPA M
7
ODEL
E
I
A,G,
U
2
AT
G
4
K
WF
FM L,O
E
C H
8
P
1
Multi’ssage Jet P 1 Rotopulse R 2
5
Shower Head SH 3 Aromatherapy AT 1 Foot Jet FM 3
Diverter Valves V 2 Safety Suction U 5 Mini Skimmer K 1 Air Control I 6 Spa Light L 1 Drain Valve 5 1
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP Pump #2 peak (continuous) HP 2 4.0 (2.0) HP 4.0 (2.0) HP Pump #3 peak (continuous) HP 3 4.0 (2.0) HP 4.0 (2.0) HP Air Bubbler 4 1.5 HP 1.5 HP
Electronics
Electrical Can 6 Gecko XM Series Gecko XM Series Voltage 240 240 Amperage 50 2x16 / 1x32 / 3x16 Heater H 4.0 KW 3.8 KW
Operation System
Main Spa Side Control 7 Gecko 600 Series Gecko 600 Series Secondary Spa Side Control 8 Optional (100 Series ) Optional (100 Series)
SPECIAL FEATURES
Spa Pillows 3 Motion Glow™ Light Standard Stainless Steel Jetting Optional Waterfall Jet/Control Valve WF, C Standard Illusion Lighting Optional SoundWave™ LX Audio Optional*
G
A,G
V
3
6
OZ
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
18
LX S
ERIES SPECIFICATIONS
—B
ALI
GENERAL rev. 2009 / 01
Seating Capacity 7 Shell Material Acrylic Dimensions (Domestic) 94” (7’10”) sq. x 39” (3’3”) Dimensions (Export) 240 cm. sq. x 99 cm. Water Capacity 650 Gallons ( 2,460 liters) Dry Weight 908 lbs (412 kg.) Skirt Material Permawood™ or Cedar Water Flow 510 Gallons per Minute
WATER SYSTEM ** (photo ref.)
Water Treatment System OZ Ozonator Filter 25 sq. ft. Slide Valves 6 Mega Swirl Jet A 6 Large Euro Jet w/ Eyeball E 22 Mega’ssage Jet G 12 Ozone Jet O 2 Multi’ssage Jet P 1 Rotopulse R 2 Shower Head SH 0 Aromatherapy AT 1 Foot Jet FM 3
Diverter Valves V 2 Safety Suction U 5 Mini Skimmer K 1 Air Control I 6 Spa Light L 1 Drain Valve 5 1
SPA M
ODEL
1
V
G
A
8
U
A,G
E
O
FM
K
P,E
V
A,G
WF
I
SPECIAL FEATURES
Spa Pillows 4 Motion Glow™ Light Standard Stainless Steel Jetting Optional Waterfall Jet/Control Valve WF,C Standard Illusion Lighting Optional SoundWave™ LX Audio Optional*
L
G
3
2
E
AT
C
5
4 6
H oz
7
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP Pump #2 peak (continuous) HP 2 4.0 (2.0) HP 4.0 (2.0) HP Pump #3 peak (continuous) HP 3 4.0 (2.0) HP 4.0 (2.0) HP Air Bubbler 4 1.5 HP 1.5 HP
Electronics
Electrical Can 6 Gecko XM Series Gecko XM Series Voltage 240 240 Amperage 50 2x16 / 1x32 / 3x16 Heater H 4.0 KW 3.8 KW
Operation System
Main Spa Side Control 7 Gecko 600 Series Gecko 600 Series Secondary Spa Side Control 8 Optional (100 Series ) Optional (100 Series)
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
19
LX S
GENERAL rev. 2009 / 01
Seating Capacity 6 Shell Material Acrylic Dimensions (Domestic) 90” (7’6”) x 79” (6’7”) x 36” (3’) Dimensions (Export) 229 cm. x 201 cm. x 92 cm. Water Capacity 325 Gallons (1,230 liters) Dry Weight 725 lbs. (329 kg.) Skirt Material Permawood™ or Cedar Water Flow 510 Gallons per Minute
WATER SYSTEM ** (photo ref.)
Water Treatment System OZ Ozonator Filter 25 sq. ft. Slide Valves 2 Mega Swirl Jet A 3 Large Euro Jet w/ Eyeball E 23 Mega’ssage Jet G 7 Ozone Jet O 2 Multi’ssage Jet P 1 Rotopulse R 2 Shower Head SH 3
ERIES SPECIFICATIONS
—B
ISCAYNE SPA MODEL
3
WF
C
I
V
4
G
A
K
E
AT
E
FM,O
L
G
2
P,E
8
G
U
A,E
Aromatherapy AT 1 Foot Jet FM 2
Diverter Valves V 2 Safety Suction U 5 Mini Skimmer K 1 Air Control I 5 Spa Light L 1 Drain Valve 5 1
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP Pump #2 peak (continuous) HP 2 4.0 (2.0) HP 4.0 (2.0) HP Pump #3 peak (continuous) HP 3 4.0 (2.0) HP 4.0 (2.0) HP Air Bubbler 4 1.5 HP 1.5 HP
Electronics
Electrical Can 6 Gecko XM Series Gecko XM Series Voltage 240 240 Amperage 50 2x16 / 1x32 / 3x16 Heater H 4.0 KW 3.8 KW
Operation System
Main Spa Side Control 7 Gecko 600 Series Gecko 600 Series Secondary Spa Side Control 8 Optional (100 Series ) Optional (100 Series)
SPECIAL FEATURES
Spa Pillows 3 Motion Glow™ Light Standard Stainless Steel Jetting Optional Waterfall Jet/Control Valve WF, C 1 Illusion Lighting Optional SoundWave™ LX Audio Optional*
6
7
1
H
oz
5
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
20
LX S
GENERAL rev. 2009 / 01
Shell Material Dimensions (Domestic) Dimensions (Export) 152 cm. x 213 cm. x 84 cm. Water Capacity Dry Weight Skirt Material Water Flow 187 Gallons per Minute
WATER SYSTEM ** (photo ref.)
Water Treatment System OZ Ozonator Filter 25 sq. ft. Slide Valves 2 Mega Swirl Jet A 6 Large Euro Jet w/ Eyeball E 12 Mega’ssage Jet G 6 Ozone Jet O 2
ERIES SPECIFICATIONS
3-4 Seating Capacity Acrylic 60” (5’) x 84” (7’) x 33” (2’9”)
220 Gallons (832 liters) 625 lbs. (283 kg.) Permawood™ or Cedar
—C
ABO SPA MODEL
6
7
oz
AT
I
WF
A
E
O
4
G
U,L
K
5
8
I
I
Multi’ssage Jet P 0 Rotopulse R 0 Shower Head SH 4 Aromatherapy AT 1 Foot Jet FM 0
Diverter Valves V 1 Safety Suction U 1 Mini Skimmer K 1 Air Control I 4 Spa Light L 1 Drain Valve 5 1
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 4.0 (2.0) HP 4.0 (2.0) HP Air Bubbler 4 1.5 HP 1.5 HP
Electronics
Electrical Can 6 Gecko XM Series Gecko XM Series Voltage 240 240 Amperage 40 2x16 / 1x32 / 3x16 Heater H 4.0 KW 3.8 KW
Operation System
Main Spa Side Control 7 Gecko 600 Series Gecko 600 Series Secondary Spa Side Control 8 Optional (100 Series ) Optional (100 Series)
SPECIAL FEATURES
Spa Pillows 4 Motion Glow™ Light Standard Stainless Steel Jetting Optional Waterfall Jet/Control Valve WF,C Standard Illusion Lighting Optional SoundWave™ LX Audio Optional*
H
I
C
1
E
G
A
V
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
21
LX S
GENERAL rev. 2009 / 01
Seating Capacity 5 Shell Material Acrylic Dimensions (Domestic) 82” (6’10”) x 67” (5’7”) x 31”(2’7”) Dimensions (Export) 211 cm. x 168 cm. x 79 cm. Water Capacity 200 Gallons (757 liters) Dry Weight 575 lbs (261 kg) Skirt Material Permawood™ or Cedar Water Flow 187 Gallons per Minute
WATER SYSTEM** (photo ref.) Water Treatment System OZ Ozonator
Filter 25 sq. ft. Slide Valves 2 Mega Swirl Jet A 2 Large Euro Jet w/ Eyeball E 21 Mega’ssage Jet G 2 Ozone Jet O 2 Multi’ssage Jet P 1 Rotopulse R 2
ERIES SPECIFICATIONS
—D
YNASTY
SPA M
1
8
H
ODEL
AT
I
E
V
E
I
E
A,G
O, L
G
4
I
A,G
WF
E
C
G,
E
Shower Head SH 4 Aromatherapy AT 1 Foot Jet FM 0
Diverter Valves V 1 Safety Suction U 1 Mini Skimmer K 1 Air Control I 3 Spa Light L 1 Drain Valve 5 1
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 4.0 (2.0) HP 4.0 (2.0) HP Air Bubbler 4 1.5 HP 1.5 HP
Electronics
Electrical Can 6 Gecko XM Series Gecko XM Series Voltage 240 240 Amperage 50 2x16 / 1x32 / 3x16 Heater H 4.0 KW 3.8 KW
Operation System
Main Spa Side Control 7 Gecko 600 Series Gecko 600 Series Secondary Spa Side Control 8 Optional (100 Series ) Optional (100 Series Gecko)
SPECIAL FEATURES
Spa Pillows 2 Motion Glow™ Light Standard Stainless Steel Jetting Optional Waterfall Jet/Control Valve WF,C Standard Illusion Lighting Optional SoundWave™ LX Audio Optional*
K
6
7
OZ
5
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
22
LX S
GENERAL rev. 2009 / 01
Seating Capacity 6 Shell Material Acrylic Dimensions (Domestic) 94” (7’10”) sq. x 39” (3’3”) Dimensions (Export) 240 cm. sq. x 99 cm. Water Capacity 525 Gallons (1,987 liters) Dry Weight 865 lbs. (392 kg.) Skirt Material Permawood™ or Cedar Water Flow 510 Gallons per Minute
WATER SYSTEM** (photo ref.)
ERIES SPECIFICATIONS
Water Treatment System OZ Ozonator Filter 25 sq. ft. Slide Valves 6 Mega Swirl Jet A 4 Large Euro Jet w/ Eyeball E 29 Mega’ssage Jet G 9 Ozone Jet O 2
—F
IJI
SPA M
ODEL
8
I
A,G
K
1
G
V
U
A,G
FM
E
2
AT
E
4 6
O,L
H
OZ
Multi’ssage Jet P 1 Rotopulse R 2 Shower Head SH 4 Aromatherapy AT 1 Foot Jet FM 3
Diverter Valves V 2 Safety Suction U 5 Mini Skimmer K 1 Air Control I 5 Spa Light L 1 Drain Valve 5 1
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP Pump #2 peak (continuous) HP 2 4.0 (2.0) HP 4.0 (2.0) HP Pump #3 peak (continuous) HP 3 4.0 (2.0) HP 4.0 (2.0) HP Air Bubbler 4 1.5 HP 1.5 HP
Electronics
Electrical Can 6 Gecko XM Series Gecko XM Series Voltage 240 240 Amperage 50 2x16 / 1x32 / 3x16 Heater H 4.0 KW 3.8 KW
Operation System
Main Spa Side Control 7 Gecko 600 Series Gecko 600 Series Secondary Spa Side Control 8 Optional (100 Series ) Optional (100 Series)
SPECIAL FEATURES
Spa Pillows 4 Motion Glow™ Light Standard Stainless Steel Jetting Optional Waterfall Jet/Control Valve WF,C Standard Illusion Lighting Optional SoundWave™ LX Audio Optional*
P
C
A,G,E
WF
3
5
7
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
23
LX S
GENERAL rev. 2009 / 01
Seating Capacity 5 Shell Material Acrylic Dimensions (Domestic) 86” (7’2”) sq. x 37” (3’1”) Dimensions (Export) 218 cm. sq. x 94 cm. Water Capacity 375 Gallons (1,420 liters) Dry Weight 705 lbs (320 kg) Skirt Material Permawood™ or Cedar Water Flow 510 Gallons per Minute
WATER SYSTEM** (photo ref.)
Water Treatment System OZ Ozonator Filter 25 sq. ft. Slide Valves 6 Mega Swirl Jet A 6 Large Euro Jet w/ Eyeball E 24 Mega’ssage Jet G 11 Ozone Jet O 2
ERIES SPECIFICATIONS
—R
ENO
SPA M
ODEL
3
A,G
I
K
A
8
AT
U
O
FM
H
E
G
5 4 7
WF
6
Multi’ssage Jet P 1 Rotopulse R 2 Shower Head SH 3 Aromatherapy AT 1 Foot Jet FM 2
Diverter Valves V 2 Safety Suction U 5 Mini Skimmer K 1 Air Control I 6 Spa Light L 1 Drain Valve 5 1
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP Pump #2 peak (continuous) HP 2 4.0 (2.0) HP 4.0 (2.0) HP Pump #3 peak (continuous) HP 3 4.0 (2.0) HP 4.0 (2.0) HP Air Bubbler 4 1.5 HP 1.5 HP
Electronics
Electrical Can 6 Gecko XM Series Gecko XM Series Voltage 240 240 Amperage 50 2x16 / 1x32 / 3x16 Heater H 4.0 KW 3.8 KW
Operation System
Main Spa Side Control 7 Gecko 600 Series Gecko 600 Series Secondary Spa Side Control 8 Optional (100 Series ) Optional (100 Series)
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
SPECIAL FEATURES
Spa Pillows 4 Motion Glow™ Light Standard Stainless Steel Jetting Optional Waterfall Jet/ Control Valve WF,C Standard Illusion Lighting Optional SoundWave™ LX Audio Optional*
Dimensions are approximate.
1
P
G
V
E
oz
2
24
LX S
Seating Capacity 6 Shell Material Acrylic Dimensions (Domestic) 83” (6’10”) rd. x 38” (3’1”) Dimensions (Export) 208 cm. sq. x 94 cm. Water Capacity 325 Gallons (1,230 liters) Dry Weight 593 lbs (269 kg) Skirt Material Permawood™ or Cedar Water Flow 306 Gallons per Minute
WATER SYSTEM** (photo ref.)
ERIES SPECIFICATIONS
GENERAL rev. 2009 / 01
Water Treatment System OZ Ozonator Filter 25 sq. ft. Slide Valves 4 Mega Swirl Jet A 5 Large Euro Jet w/ Eyeball E 11 Mega’ssage Jet G 5 Ozone Jet O 2 Multi’ssage Jet P 0
—RIO SPA M
5
ODEL
SH
A
WF
A,E
G
A,G
O
G
L
U
E
K
H
AT
I
6
oz
Rotopulse R 0 Shower Head SH 3 Aromatherapy AT 1 Foot Jet FM 0
Diverter Valves V 0 Safety Suction U 3 Mini Skimmer K 1 Air Control I 2 Spa Light L 1 Drain Valve 5 1
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP Pump #2 peak (continuous) HP 2 4.0 (2.0) HP 4.0 (2.0) HP Pump #3 peak (continuous) HP 3 4.0 (2.0) HP 4.0 (2.0) HP Air Bubbler 4 1.5 HP 1.5 HP
Electronics
Electrical Can 6 Gecko XM Series Gecko XM Series Voltage 240 240 Amperage 50 2x16 / 1x32 / 3x16 Heater H 4.0 KW 3.8 KW
Operation System
Main Spa Side Control 7 Gecko 600 Series Gecko 600 Series Secondary Spa Side Control N/A n/a n/a
SPECIAL FEATURES
Spa Pillows 0 Motion Glow™ Light Standard Stainless Steel Jetting Optional Waterfall Jet/ Control Valve WF,C Standard Illusion Lighting Optional Spa Bullet Audio Optional
C
V
4
1
2
7
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
25
LX S
GENERAL rev. 2009 / 01
Seating Capacity 6 Shell Material Acrylic Dimensions (Domestic) 94” (7’10”) sq. x 39” (3’3”) Dimensions (Export) 240 cm. sq. x 99 cm. Water Capacity 425 Gallons (1,615 liters) Dry Weight 670 lbs (302 kg) Skirt Material Permawood™ or Cedar Water Flow 428 Gallons per Minute
WATER SYSTEM** (photo ref.)
Water Treatment System OZ Ozonator Filter 25 sq. ft. Slide Valves 6 Mega Swirl Jet A 2 Large Euro Jet w/ Eyeball E 16 Mega’ssage Jet G 11 Ozone Jet O 2 Multi’ssage Jet P 0 Rotopulse R 0
ERIES SPECIFICATIONS
—SUNR
ISE
SPA M
ODEL
2
8
WS
A,G
G
C
WF
FM
K*
FM
U
A,G
E
L
C
O
A,G
E
WS 4
V
AT
Shower Head SH 4
1
7
Aromatherapy AT 1 Foot Jet FM 2
Diverter Valves V 1 Safety Suction U 3 AquaSure™ Dual Filtration K* 1 Air Control I 3 Spa Light L 1 Drain Valve 5 1
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP Pump #2 peak (continuous) HP 2 6.0 (3.0) HP 6.0 (3.0) HP Air Bubbler 4 1.5 HP 1.5 HP
Electronics
Electrical Can 6 Gecko XM Series Gecko XM Series Voltage 240 240 Amperage 50 2x16 / 1x32 / 3x16 Heater H 4.0 KW 3.8 KW
Operation System
Main Spa Side Control 7 Gecko 600 Series Gecko 600 Series Secondary Spa Side Control 8 Optional (100 Series ) Optional (100 Series)
SPECIAL FEATURES
Spa Pillows 4 Motion Glow™ Light Standard Stainless Steel Jetting Optional Waterfall Jet/ Control Valve WF,C Standard 2 Water Spout / Control WS,C Standard Cascading Water Pool Standard Illusion Lighting Standard SoundWave™ LX Audio Optional*
H
OZ
6
5
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
AT S
ERIES SPECIFICATIONS
GENERAL rev. 8/2008
Seating Capacity 5 Shell Material Acrylic Dimensions (Domestic) 82” (6’10”) sq. x 36” (3’) Dimensions (Export) 208 cm. sq. x 91 cm. sq. Water Capacity 375 Gallons (1,420 liters) Dry Weight 665 lbs (302 kg) Skirt Material PermaWood™ Water Flow 250 Gallons per Minute
WATER SYSTEM** (photo ref)
Water Treatment System OZ Standard Filter suction-side 25 sq. ft.
Slide Valves 4 Mega Swirl Jet A 5 Large Euro Jet w/ Eyeball E 38 Mega’ssage Jet G 5 Ozone Jet O 2 Multissage Jet P 0 Diverter Valves V 0 Safety Suction U 3 Mini Skimmer K 0 Air Control I 3 Spa Light L 1 Drain Valve 5 1
SPECIAL FEATURES
Spa Pillows 3 Motion Glow™ Light Standard
—M
YSTIC SPA MODEL
26
II
2
A,G
A,G
EE
II
A,G
A,G
EE
5 1
U
G,
G,
UU
O
L
OZ
AA
EE
EE
WFWF
7
6,H
II
Stainless Steel Jetting N/A Waterfall Jet WF Standard Waterfall Control Valve C Standard SoundWave™ AT Audio Optional
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP Pump #2 peak (continuous) HP 2 4.0 (2.0) HP
Electronics
Electrical Can 6 Gecko XE Series Voltage 240 Amperage 40 Heater H 4.0 KW
Operation System
Main Spa Side Control 7 Gecko 450 Series Secondary Spa Side Control 8 N/A
** Not every jet is referenced. Each type of jet is noted for ease of identification. * Note location of audio components prior to install. Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet. All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
AT S
ERIES SPECIFICATIONS—ISLE SPA MODEL
GENERAL rev. 8/2008
Seating Capacity 5 Shell Material Acrylic Dimensions (Domestic) 76” (6’4”) sq. x 31” (2’7”) Dimensions (Export) 194 cm. sq. x 79 cm. Water Capacity 275 Gallons (1,041 liters) Dry Weight 530 lbs. (240 kg.) Skirt Material PermaWood™ Water Flow 187 Gallons per Minute
5
27
1
7
OZ
6,H
WATER SYSTEM** (photo ref)
Water Treatment System OZ Standard Filter suction-side 25 sq. ft. Slide Valves 2 Mega Swirl Jet A 3 Large Euro Jet w/ Eyeball E 27 Mega’ssage Jet G 1 Multi’ssage Jet P 0 Ozone Jet O 2 Diverter Valves V 0 Safety Suction U 1 Mini Skimmer K 0 Air Control I 3 Spa Light L 1 Drain Valve 5 1
SPECIAL FEATURES
Spa Pillows 3 Motion Glow™ Light Standard Stainless Steel Jetting N/A Waterfall Jet WF Standard Waterfall Control Valve C Standard SoundWave™ AT Audio N/A
C
I
WF
E,G
L
E
O
U
A
E
I
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz)
Pump #1 peak (continuous) HP 1 4.0 (2.0) HP
Electronics
Electrical Can 6 Gecko XE Series Voltage 240 Amperage 40 Heater H 4.0 KW
Operation System
Main Spa Side Control 7 Gecko 450 Series Secondary Spa Side Control 8 N/A
** Not every jet is referenced. Each type of jet is noted for ease of identification. Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet. All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
AT S
ERIES SPECIFICATIONS
GENERAL rev. 8/2008
Seating Capacity 8 Shell Material Acrylic Dimensions (Domestic) 82” (6’10”) sq. x 39” (3’3”) Dimensions (Export) 208 cm. sq. x 99 cm. sq. Water Capacity 425 Gallons (1,609 liters) Dry Weight 645 lbs. (293 kg.) Skirt Material PermaWood™ Water Flow 250 Gallons per Minute
—M
IRAGE SPA MODEL
28
I
WATER SYSTEM** (photo ref.)
Water Treatment System Ozone Standard Filter suction-side 25 sq. ft. Slide Valves 4 Mega Swirl Jet A 2 Large Euro Jet w/ Eyeball E 39 Mega’ssage Jet G 7 Multi’ssage Jet P 0 Ozone Jet O 2 Diverter Valves V 0 Safety Suction U 3 Mini Skimmer K 0 Air Control I 3 Spa Light L 1 Drain Valve 5 1
SPECIAL FEATURES
Spa Pillows 2 Motion Glow™ Light Standard Stainless Steel Jetting N/A Waterfall Jet WF Standard Waterfall Control Valve C Standard SoundWave™ AT Audio Optional*
I
E
A
G,E
U
A,E
G
O,L
I
2
E
G
WF
6,H
7
C
OZ
1 5
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz)
Pump #1 peak(Continuous) HP 1 2.0 (1.0) HP Pump #2 peak(Continuous) HP 2 4.0 (2.0) HP
Electronics
Electrical Can 6 Gecko XE Series Voltage 240 Amperage 50 Heater H 4.0 KW
Operation System
Main Spa Side Control 7 Gecko 450 Series Secondary Spa Side Control 8 N/A
** Not every jet is referenced. Each type of jet is noted for ease of identification. * Note location of audio components prior to install. Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet. All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
28
SPA I
I
NSTALLATION GUIDELINES
THE
MENT ACCUMULATION, WATER SPILL-OVER, ETC. WHICH ARE CONSIDERATIONS FOR THOSE LOCATED INSIDE
NSTALLATION
LOCATION OF YOUR SPA IS AN IMPORTANT FACTOR IN GUARANTEEING YOUR MAXIMUM SPA ENJOY-
. G
ENERALLY, MOST SPAS ARE INSTALLED OUTDOORS WITH NO CONCERNS REGARDING MOISTURE
O
UTDOOR INSTALLATION CONSIDERATIONS
1. L
2. C YOU
3. V
4. D
5. N
6. L
7. C
8. IF C
9. A
10. BE
11. P
12. L
BE GROUND FAULT CIRCUIT PROTECTED AT THE POWER SOURCE. ALL ELECTRICAL WIRING OF THE SPA SUPPORT EQUIPMENT MUST COMPLY WITH THE NATIONAL ELECTRIC CODE.
13. L
MUST COMPLY WITH ARTICLE 680 OF THE U.S. NATIONAL ELECTRIC CODE AND ANSI/NFPA 70-1984.
14. P
OCAL ELECTRICAL AND PLUMBING CODES
ONSIDER LOCAL CODES PERTAINING TO FENCING, ENCLOSURES, WALLS, ELECTRICAL AND PLUMBING
BOTH ABOVE GROUND AND UNDERGROUND IEW FROM HOUSE FOR AESTHETICS AND SUPERVISORY NEEDS ISTANCE FROM HOUSE FOR WINTERTIME SOAKING IGHTTIME LIGHTING
OCATE THE SPA WITH AN AWARENESS TO SUNLIGHT EXPOSURE, VIEWS, ACCESS, PROPERTY LINES
LIGHTING, WIND DIRECTION, SHIELDING, SEPTIC TANKS, PLANTS, TREES
WATER SPLASHED FROM YOUR SPA MAY DAMAGE NEARBY PLANT LIFE
ONSIDER THE LOCATION OF THE NEAREST BATHROOM
YOUR SPA IS TO BE LOCATED ON A SECOND STORY, BE POSITIVE SUPPORT IS ADEQUATE
REA FOR PLACEMENT OF SUPPORT EQUIPMENT WHERE ADEQUATE SPACE WILL BE NEEDED TO GAIN
ACCESS TO COMPONENTS FOR MAINTENANCE AND GENERAL SERVICING
SURE TO NOTE ANY OTHER CONSIDERATIONS, SUCH AS AESTHETICS OR PRIVACY CONCERNS, THAT
MAY AFFECT THE SAFETY OR ENJOYMENT OF USING THE SPA
ROVIDE ADEQUATE DRAINAGE AWAY FROM THE EQUIPMENT AND ADEQUATE ELEVATION TO ALLOW
DRAINING BY SIPHON, IF SHOULD BE REQUIRED
OCATION OF ELECTRICAL SUPPLY
THE ELECTRICAL SOURCE TO THE SPA SUPPORT PACK TERMINAL
OCATIONS AT LEAST
WITHIN
5
FEET OF METALS SURFACES PROVIDING EACH METAL SURFACE IS PERMANENTLY CONNECTED BY A NO CONNECTOR ON THE TERMINAL BOX PROVIDED FOR THIS PURPOSE
LACE THE SPA ON A FIRM, LEVEL SURFACE THAT WILL NOT SHIFT
.
WILL NEED TO ENSURE THAT YOUR SPA IS AN ADEQUATE DISTANCE FROM POWER LINES
. Y
OUR SPA WILL ALSO NEED TO BE CHILDPROOFED
.
.
.
. (C
HEMICALS IN THE SPA
.)
.
.
ALL YOUR BUILDER
. 8AWG (8.4 MM2)
.
5 FT (1.52 M)
.
.
. 120/240
VOLT SYSTEMS REQUIRE HARD WIRE INSTALLED FROM
. ALL EQUIPMENT MUST
FROM ALL METAL SURFACES
COPPER CONDUCTOR ATTACHED TO THE WIRE
. (A
SPA MAY BE INSTALLED
.) ALL INSTALLATIONS
.
.
.
.
,
.
,
29
SPA I
I
NSTALLATION GUIDELINES
I
1. L
2. V
3. C
4. D
5. C
6. C
7. R
8. DO
9. THE
NSTALLATION
NDOOR
I
NSTALLATION CONSIDERATIONS
OCAL ELECTRICAL AND PLUMBING CODES
ENTILATION FANS AND/OR DEHUMIDIFIERS SHOULD BE PROVIDED TO HANDLE THE HIGH HUMIDITY
DEVELOPED BY YOUR SPA
HEMICALS WILL VAPORIZE FROM THE WATER AND MAY CAUSE AN ODOR AND POSSIBLY CORROSION
TO CERTAIN HOME HARD-WARE
URING THE NORMAL USE OF THE SPA, WATER WILL ESCAPE THE SPA VESSEL
ON OR OVER ANY MATERIAL WHICH MAY BE DAMAGED BY THIS WATER OR THE CHEMICALS WITHIN THE WATER AVOID WATER DAMAGE, EVEN IF THE SPA SHOULD LOSE ALL ITS WATER
ONSIDER AND PREPARE FOR THE UNLIKELY EVENT OF RAPID SPA DRAINAGE
SPA IS PERMANENT, YOU MAY WISH TO PROVIDE FLOOR DRAINS TO ACCOMMODATE DRAINING ETC
NECESSARY ONSIDER AND PREPARE FOR THE UNLIKELY EVENT OF SPA REMOVAL EAD
7-14 IN
NOT SET SPA ON FINISHED FLOOR WITHOUT A WATERPROOF BARRIER PROTECTION UNDERNEATH
SPA SHOULD HAVE ACCESS TO A POWER SOURCE CAPABLE OF SUPPLYING
IT I
10. THE
11. BE
12. DO
13. THE
14. BE
NTERRUPTER
SHOULD BE ON THE SAME CIRCUIT
SPA SHOULD BE CLOSE TO A SOURCE OF WATER
SURE THAT THE LOCATION YOU CHOOSE IS STABLE
THE SPA WHEN IT IS FILLED WITH WATER, PLUS THE WEIGHT OF THE OCCUPANTS
WEIGH UP TO
NOT USE THE SPA ABOVE A FINISHED LIVING AREA, DUE TO THE RISK OF WATER DAMAGE
SPA IS NOT DESIGNED FOR IN-FLOOR INSTALLATION
SYSTEM THAT IS BUILT FLUSH WITH THE TOP OF THE SPA, PROVIDED YOU LEAVE ACCESS FOR
SERVICE
SURE TO NOTE ANY OTHER CONSIDERATIONS, SUCH AS AESTHETICS OR PRIVACY CONCERNS, THAT
MAY AFFECT THE SAFETY OR ENJOYMENT OF USING THE SPA
WARNING:
A KNOWLEDGE OF CONSTRUCTION TECHNIQUES, PLUMBING AND ELECTRICAL
INSTALLATION ACCORDING TO CODES ARE REQUIRED FOR PROPER INSTALLATION
AND USER SATISFACTION. WE RECOMMEND THAT A LICENSED CONTRACTOR
PERFORM THE INSTALLATION. OUR WARRANTY DOES NOT COVER
.
. W
ALLS, CEILING AND WOOD TRIM SHOULD BE RESISTANT, ALSO
. N
EVER STORE CHEMICALS INSIDE THE SPA CABINET
. N
EVER PLACE THE SPA
. K
EEP DAMAGEABLE MATERIALS FAR ENOUGH AWAY FROM THE SPA TO
.
. IF
PLACEMENT OF THE
. A
LWAYS LEAVE ROOM ALL AROUND THE SPA FOR EASY ACCESS IN CASE REPAIRS ARE
.
.
THE OUTDOOR INSTALLATIONS INFORMATION
MUST BE WIRED DIRECTLY INTO A GROUNDED CIRCUIT WITH A GROUND FAULT CIRCUIT
(G.F.C.I.)OR
EQUIVALENT
RCD,
.
FOR EXPORT INSTALLS
240
VOLTS
. NO
OTHER APPLIANCES
.
.
. IT
MUST BE ABLE TO SUPPORT THE WEIGHT OF
6000
LBS
( 2722 KG.)
WHEN IT IS FILLED WITH WATER
. H
OWEVER, IT IS COMPATIBLE WITH A DECK
.
.
.
THIS IS A PROFESSIONAL GRADE PRODUCT.
IMPROPER INSTALLATION-RELATED PROBLEMS.
.
AC
. THE
POWER
SPA MAY
.
.
,
.
.
30
SPA I
G
ENERAL LOCATION CONSIDERATIONS
R
LOCATION LBS ON THE GROUND PREPARING THE SITE FOR THE HOT TUB INSTALLATION
NSTALLATION
EVIEW OUTDOOR INSTALLATIONS AND INDOOR INSTALLATIONS PRIOR TO CHOOSING YOUR SPA
. Y
OUR SPA SHOULD BE PLACED ON A LEVEL CONCRETE PAD OR ON A DECK DESIGNED TO SUPPORT
(2722 KG.) OR ON
. O
PATIO BLOCKS ON THE GROUND
NCE YOU HAVE A LOCATION SELECTED, THERE ARE SEVERAL ISSUES YOU SHOULD CONSIDER IN
A
IS FILLED, IT HAS CONSIDERABLE WEIGHT OF
100
SPA RESULTING FROM THE INCORRECT INSTALLATION OF PLACEMENT ON INADEQUATE FOUNDATION IS NOT COV­ERED IN THE SPA’S LIMITED WARRANTY
FLAT, LEVEL SURFACE THAT IS STRONG ENOUGH TO SUPPORT YOUR SPA IS REQUIRED
LBS
(45.4 KG)
PER SQUARE FOOT LOAD, PER RECOMMENDED GUIDELINES
M
DECK UNIT IS PLACED DIRECTLY ON THE GROUND, YOU WILL WANT TO REMOVE THE GRASSY LEVEL, AND PLACE A LAYER OF GRAVEL ON THE SOIL SOLID LUMBER TO ACHIEVE A LEVEL SURFACE CONVENIENT WAY TO PREPARE THE LOCATION SITE TENDENCY TO SETTLE AND MAY BECOME AT LEAST FOUR INCHES THICK WITH THE REINFORCING MESH OR ROD ATTACHED TO A BOND WIRE
OST UNITS ARE INSTALLED OUTSIDE, ON GROUND LEVEL, ON EITHER A CONCRETE PAD OR A WOODEN
. IF
THE SPA IS NOT ON GROUND LEVEL, HAVE A BUILDER DETERMINE IF THE SUPPORT IS ADEQUATE
. THE
M
ONTO THE WEB SITE OR CALL YOUR RETAILER FOR DIMENSIONS OF THE MODEL YOU HAVE CHOSEN PERIMETER OF THE CHOSEN GROUND SURFACE TO EXTEND BEYOND THE SPA ITSELF TO PROVIDE A CLEAN AREA FOR USERS TO GET IN AND OUT OF THE SPA
AKE SURE YOUR DIMENSIONS ARE CORRECT AS YOU PREPARE THE SITE FOR YOUR NEW HOT TUB
THE
SPA LOCATION AND THE SPA ITSELF MUST BE LEVEL BEFORE FILLING WITH WATER
S
RESISTANT QUALITIES, IF A PRESSURE-TREATED TYPE LUMBER IS USED CONSULT A BUILDER TO DETERMINE IF YOUR DECK IS OF ADEQUATE STRENGTH
HOULD YOUR SPA SITE BE A WOODEN DECK, THIS PROVIDES A CLEAN AREA WITH WEATHER AND ROT
IF
UNLIKELY EVENT OF RAPID SPA DRAINAGE
INSTALLING YOUR HOT TUB BELOW GRADE, CONSIDER ADEQUATE DRAINAGE FOR RUN-OFF AND THE
A
CABINET THE SUPPORT EQUIPMENT FOR THE MODEL YOU HAVE CHOSEN
LLOW ADEQUATE SPACE TO ACCESS THE EQUIPMENT BEHIND THE FOUR ACCESS PANELS ON THE HOT TUB
. R
EVIEW THE PAGES IN THIS MANUAL REFERENCING SPA MODEL SPECIFICATIONS FOR THE LOCATION OF
L
EAVE AMPLE ACCESS TO THE
A
SPA AND WITHIN THE LINE OF SIGHT FROM THE HOT TUB ING AND PREPARING THE SPA SITE
QUICK DISCONNECT (MANUAL DISCONNECT) IS TO BE INSTALLED BETWEEN
A
EASY DRAINING
A
DVANTAGEPACK DESIGN; WITH THIS FEATURE, ALL THE EQUIPMENT IS LOCATED BENEATH AN END CABINET
A
LLOW EASY ACCESS TO ALL COMPONENTS
CABINET SIDE DRAIN HAS BEEN INSTALLED ON THE BOTTOM PORTION OF A CABINET SIDEWALL FOR
. L
OCATE THIS DRAIN AND LEAVE AMPLE ACCESS
6000
. DO
NOT PLACE THE SPA ON A DIRT SURFACE OR DIRECTLY
.
. O
NCE YOUR SPA
. M
AKE CERTAIN THE LOCATION YOU CHOOSE CAN SUPPORT A MINIMUM
. S
TRUCTURAL DAMAGE TO THE
.
BEST WAY TO LEVEL THE GRAVEL MAY BE WITH THE STRAIGHT EDGE OF A PIECE OF
. P
AVERS PLACED IN A SAND BASE IS ALSO A RATHER QUICK AND
. N
OTE THAT PAVERS, STEPPING STONES, ETC. STILL HAVE A
UNLEVEL AT SOME POINT
. A
REINFORCED CONCRETE SLAB SHOULD BE
.
. A
LLOW A
.
.
. C
ONSIDER THE LOAD REQUIREMENTS AND
.
.
.
GFCI
CIRCUIT BREAKER FOR TESTING, ETC
.
5 - 15 FT (1.5-4.6 M) OF
. C
ONSIDER WHERE THIS CAN BE LOCATED WHEN
. ALL
WIRING MUST COMPLY WITH THE
. Y
. T
HIS DESIGN ALSO FEATURES A SIDE DRAIN FOR EMPTYING
U.S. N
OUR SPA MAY HAVE BEEN CHOSEN WITH THE
ATIONAL ELECTRIC CODE
.
. IF
. C
SELECT-
.
THE
LICK
THE
.
31
SPA I
E
QUIPMENT LOCATION
FOR S
A
LOCATION REMOVE A CABINET ACCESS PANEL USING A SQUARE HEAD SCREWDRIVER
NSTALLATION
LIMLINE DESIGN SPAS
FTER THE HOT TUB HAS BEEN PLACED IN THE DESIRED
N
ELECTRICAL BOX, PUMP (OR PUMPS ATTACHED BEHIND THE ELECTRICAL BOX ALLOWED AMPLE SPACE AROUND THE NECESSARY CABINET SIDES TO ACCESS EQUIPMENT IN THIS MANUAL FOR A GUIDE OF EQUIPMENT LOCATION FOR THAT SPECIFIC SPA MODEL
EXT, PULL AWAY THE CABINET PANEL AND LOCATE THE
FOR S
LIMLINE AND ADVANTAGEPACK DESIGN SPAS
N
NEED TO BE ACCESSED TO COMPLETE THE WIRING CONNECTION TO THE HOME POWER SOURCE THIS IS LOCATED BENEATH THE END CABINET WITH OTHER SUPPORT COMPONENTS
N
OTE THAT THE
S
ERIES SPAS
THE CORRECT PLATFORM FOR YOUR SPA UNIT
OTE THE LOCATION OF THE ELECTRICAL BOX, THIS WILL
:
. (SEE
. P
. R
ILLUSTRATION
. R
EVIEW YOUR SPA MODEL SPECIFICATION PAGE
)
),
AIR BLOWER
. N
OTE THE HEATER
. BE
SURE YOU HAVE
.
:
. FOR A
HOTO TO THE RIGHT FEATURES THE
XE
PLATFORM MAY BE USED ON THE
EFER TO THE SPA SPECIFICATION PAGE TO IDENTIFY
DVANTAGEPACK DESIGN UNITS
XM
PLATFORM
SE AND AT
..
,
.
FOR S
LIMLINE AND ADVANTAGEPACK DESIGN SPAS
C
THE LOCKING CLIP HAS REMAINED SNAPPED ON THE VALVE STEM DURING SHIPMENT
HECK THAT ALL VALVES: TWO PER PUMP, ARE OPEN AND
. ( SEE
ILLUSTRATION
)
:
FOR S
LIMLINE AND ADVANTAGEPACK DESIGN SPAS
THE
OUS COLLARS AND HAND-TIGHTEN ALL COLLARS CHECKING FOR ANY WHICH MAY HAVE LOOSENED DURING SHIPMENT
SPA EQUIPMENT HAS BEEN ASSEMBLED WITH NUMER-
(
UNIONS) FOR EASE OF FUTURE SERVICING
. ( SEE
ILLUSTRATION
:
. L
OCATE
)
THE SPA SUPPORT EQUIPMENT MUST BE PLACED AT OR BELOW THE WATER LEVEL OF THE SPA.
NEVER PLACE THE EQUIPMENT ABOVE THE SPA WATER LEVEL.
ALL PDC EQUIPMENT MUST BE IN A SHELTERED ENVIRONMENT THAT WILL PROTECT THE
EQUIPMENT FROM RAIN, SLEET, SNOW, AND DIRECT SUNLIGHT. R
EFER TO SPA SPECIFICATION PAGES IN THIS MANUAL FOR THE LOCATION OF EQUIPMENT FOR THE MODEL YOU
HAVE CHOSEN
.
INSTALLATION AND WIRING IS TO BE COMPLETED BY A QUALIFIED ELECTRICIAN
.
32
SPA I
I
NSTALLING THE THERMAL COVER
R
THE SPA COVER AND HOLD LATCH AGAINST THE CABINET SIDE PANEL PERSON HOLD THE STRAP TIGHT ON THE OPPOSITE SIDE OF THE SPA COVER PLACE THE LATCH OVER THE GROOVES OF THE CABINET FIN­ISH TO THE CABINET SIDE PANEL WITH THREE PROVIDED CABINET IN THE SAME MANNER
NSTALLATION
EMOVE THE SPA COVER FROM THE BOX AND PLACE IT ON THE SPA
. TO
POSITION THE LOCK CORRECTLY, HAVE A SECOND
. THE
. R
EMOVE THE LATCH FROM THE LOCK, ATTACH THE LOCK
. A
TTACH THE OTHER THREE LOCKS TO THE
SPA COVER MUST BE TIGHT
. P
ULL DOWN ONE OF THE STRAPS ON
. DO
NOT
#4
SCREWS
.
TO
SPA COVER INTO THE LOCKS ON THE CABINET SIDE PANEL COVER IN PLACE, INSERT THE KEY AND TURN IT CLOCKWISE
TO
UNLOCK THE LATCHES, INSERT THE KEY AND TURN IT COUNTER­CLOCKWISE SPA IS NOT IN USE OF CHILDREN
SECURE THE HOT TUB COVER, SNAP THE LATCHES ON THE
. TO
1/4
1/4
TURN
. A
LWAYS KEEP THE COVER LOCKED WHEN THE
. K
EEP THE KEYS IN A SAFE PLACE, OUT OF THE REACH
.
LOCK THE
TURN
.
33
W
IRING INSTALLATION
W
IRING GUIDELINES
ALL EQUIPMENT MODELS ARE 120/240 VOLT, 60 CYCLE FOR STATE-SIDE, U.S. INSTALLATIONS,
AND 50 HZ FOR EXPORT, CE, INSTALLATIONS.
ALL SPAS MUST BE PERMANENTLY CONNECTED.
ALL SPA SUPPORT SYSTEMS ARE MULTIPLE SUPPLY CIRCUITS.
ALL SPA SYSTEMS REQUIRE THE INSTALLATION OF A GROUND FAULT CIRCUIT INTERRUPTER PROTECTOR (GFCI) OR EQUIVALENT; RCD, FOR EXPORT INSTALLS, AT THE POWER SOURCE (NOT SUPPLIED) BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH ALL CODES AND REGULATIONS. REFER TO TYPICAL G.F.C.I. INSTALLATION ON FOLLOWING PAGE.
PRIOR TO EACH USE, TESTING OF THE GFCI (OR EQUIVALENT) IS REQUIRED. REFER TO THE MAINTE NANCE SECTION OF THIS MANUAL FOR INSTRUCTIONS.
ALL SPA SUPPORT EQUIPMENT MUST BE BONDED (GROUNDED) TO THE PRESSURE CONNECTOR LOCATED WITHIN THE CONTROL PANEL, AS WELL AS THE BONDING TERMINAL LOCATED ON THE OUTSIDE OF THE CONTROL PANEL. (see wiring schematic below)
DISCONNECT ALL ELECTRICAL SUPPLIES AND CONTACT A QUALIFIED TECHNICIAN BEFORE SERVICING.
ALL SPA INSTALLATIONS ARE TO BE PERFORMED BY A LICENSED ELECTRICIAN AND IN ACCORDANCE
WITH ALL LOCAL AND NATIONAL CODES.
O
PTION
O
PTION
1
M
AIN PANEL
C
IRCUIT BREAKER
G.F.C.I.
2
M
AIN PANEL
C
IRCUIT BREAKER
* N
ATIONAL
SPA W
IRING SCHEMATIC FOR CERTIFIED ELECTRICIANS
U.S.
CODE RECOMMENDS DISTANCE NOT TO EXCEED
W
IRE
“A” W
W
IRE
“A” W
D
ISCONNECT
D
ISCONNECT
G.F.C.I.
15 FT.
’ R
EFERENCE ONLY
IRE
IRE
“B” *
“B” *
SPA
SPA
W
IRING INSTALLATION
W
IRING GUIDELINES
ALL PDC SPA U
ALL APPLICABLE CODES
F
OLLOW EACH MANUFACTURER’S GUIDELINES TO ENSURE PROPER OPERATION AND
PROTECTION OF SPA OCCUPANTS
34
—STATE-SIDE GUIDELINES
- S
TATE-SIDE
(U.S. I
NSTALLATIONS
)
ATTENTION ELECTRICIAN:
NITS MUST BE INSTALLED WITH AN APPROVED
. I
NSTALLATION OF
BE USED ONLY AS A REFERENCE FOR THE INSTALLING ELECTRICIAN
T
YPICAL INSTALLATION BREAKER BOX
C
LASS
A 50
G.F.C.I.
. T
HIS DIAGRAM IS A
AMP
, 120/240
VARIES AMONG THOSE MANUFACTURERS
G.F.C.I. IN
“T
YPICAL” INSTALLATION TO
ACCORDANCE WITH
VOLT
, GFCI
.
.
Ground Bar Attached To Box Input & Output
Ground to Spa
Ground Input
Load 120V (Black) To Spa
Load 120V (Red) To Spa
Load Neutral (White) To Spa
To Spa (OUTPUT)
TO BE NOTED: Installation of this GFCI Circuit Breaker, including ampere sizing and choice of qualified electrician in accordance with the National Electrical Code, and all applicable federal, state and local codes and regulations in effect at the time of installation.
Line (BLACK) House Input
Line (RED) House Input
Pig Tail (WHITE) From GFCI Breaker Going to Neutral Bar in Box
Load Neutral Bar
Line Neutral (WHITE) House Input
From House (INPUT)
TO BE NOTED: The white neutral wire from the back of the GFCI Circuit Breaker MUST be connected to an incoming Line Neutral. The internal mechanism of the GFCI requires this Neutral connection for proper GFCI function.
IMPORTANT: 6 G
T
EST
GFCI M
ONTHLY AND PRIOR TO EACH USE
AUGE COPPER WIRE
MUST BE U
.
SED
system. It’s important to note that on a polyphase power system,
Connect th e bonding
35
W
IRING INSTALLATION
W
IRING INSTALLATION
—EXPORT GUIDELINES IN.XM CE
—EXPORT GUIDELINES IN.XM CE
INSTALLATION GUIDELINES for IN.XM CE
ALL
INSTALLATIONS AND CONNECTIONS ARE TO BE PERFORMED BY A QUALIFIED, LICENSED ELECTRICIAN ONLY AND IN ACCORDANCE WITH LOCAL REGULATIONS WITH THE HOME’S ELECTRICAL OUTPUT, AND FOLLOW THE GUIDELINES BELOW MAKING ANY ELECTRICAL CONNECTIONS
. I
DENTIFY THE CORRECT
.
CE
PLATFORM ON THE SPA UNIT, IN ACCORDANCE
. E
NSURE POWER IS TURNED OFF PRIOR TO
!
a rated operating residual-current not exceeding 30 mA. Proper wiring of the electrical service box, RCD and in.xm.ce terminal block is essential! Check your electrical code for local regulations. Only copper
This product must always be connected to a circuit protected by a residual-current device (RCD) having
Warning!
wire should be used, never aluminum.
Standard with 600 Series
control on all LX Series Units
IN.XM P
LATFORM CONTROL CENTER
1 x 230 VAC (1 x 32A) single phase,
or
1 x 230 VAC (2 x 16A) dual phase,
or
1 x 230 VAC (3 x 16A) three phase
W
HEN INSTALLING THE IN.XM.CE POWER BOX WE RECOMMEND THE FOLLOWING
SE Series upgraded platform,
400 Series control
:
Bonding lug
To install the wiring for the in.xm.ce spa control, you’ll need a Phillips screwdriver, a 14 mm (9/16”) nut driver or a flat screwdriver. Loosen the 2 screws of the spa pack door and open it. Remove 200 mm (8”) of cable insulation. Strip away 25 mm (1”) of each wire insulation. Pull the cable through the cutout of the box and use an IEC certified plastic bushing that will maintain the IPX5 rating. Also, the power cord must be in accordance with the national electrical code of the country in which it’s to be installed and must maintain IPX5 rating. Make sure that only the uncut sheathing is clamped at this opening. Push the color-coded wires into the terminals as indicated on the sticker, use the 14mm (9/16”) wrench or flat screwdriver to tighten the bolts on the terminals. After making sure wire connections are secure, push them back into the box and close the door. Tighten the 2 screws of the spa pack door.
An IEC certified bushing that will maintain the IPX5 rating must be used. The power cord must be in accordance with the national electrical code of the country in which the in.xm.ce is to be installed.
Dual phase system: two electrical phases out of a three-phase power
all electrical phases must share the same neutral.
1x230 VAC(1x32A) Single phase
1x230 VAC(2x16A) Dual phase
1x230 VAC(3x16A) Three phase
Make sure all accessories are linked to the bonding connector and connected to the pack. Electrical connections should be made only by qualified personnel and in accordance with local regulations.
conductor to the bonding lug on the left side of the in.xm.ce spa pack (a grounded electrode conductor shall be used to connect the equi p m ent g r oun d i n g conductors).
W
IRING INSTALLATION
36
—EXPORT GUIDELINES IN.XM CE
Case 1 Single-phase 1 x 230 VAC (32 A max)
The installation of electrical circuit jumpers is needed in certain input supply configura­tions.
Use uncut jumper as supplied in the case of an input supply wiring,
POWERING UP the IN.XM CE
Make sure all accessories are linked to the bonding connector and connected to pack.
Make sure the spa pack door is closed. Turn on the breaker. It is important to specify the phase
configuration setting at the power supply: single phase (1P), dual phase (2P), or three phase (3P) (see configuration below)
Case 2 Dual-phase 1 x 230 VAC (2 x 16 A max)
For this input supply wiring, you will need to cut off a portion of jumper piece. Proceed as follows:
Use pliers to firmly hold upper
Case 3 Three-phase 1 x 230 VAC (3 x 16 A max)
Please note that in a three­phase system , no jumper installation is required.
half of the metal jumper, then break off other half.
LOW LEVEL SPA CONFIGURATION COMPONENT PUMP1 PUMP2 PUMP3 BLOWER LL1 X LL2 X X LL3 X X X LL4 X X X X
NOTE: Low level programming (LL) has been factory preset. In the course of setting the incoming power should “LL” be shown on screen, there should be no changes made to this setting. Immediately exit the LL menu by pushing the select button. If the LL configuration was changed, refer to chart above to review proper LL settings.
Press Select button to select proper phase configuration set­ting. The in.scan display will show “xP”, with “X” represent­ing the number of phases of the electric power system.
RCD Br
1X32A 1P 2X16A 2P 3X16A 3P
Important!
Safely dispose of the discarded portion in accordance with the local waste disposal legislation in force.
Use Change button to go from one parameter to the next.
Press Select button again to make the correct selection.
All receptacles will match the corre­sponding female connection on the spa pack.
No connections should remain unplugged. Use blank plugs to fill unused connectors.
CONFIGURING the IN.XM CE
Description: Phase setting appears (P) at power up. Press Change button to choose proper phase setting. Press Select button to lock in
proper phase. Breaker setting appears (BR). Press Change button to choose proper breaker setting. Select button is used to access the phase configuration setting menu (short press) as well as the low level programming menu (press and hold for 5 seconds). Subsequent presses will save changes and display the next option available or exit automatically if it was the last one. Use Change button to change the parameters displayed. Note: this procedure has to be performed after every learning mode.
Setting the Learning Mode: The in.xm.ce pack has the ability to verify and “learn” the current consumption of every output connected to it. If an output is replaced, a new learning must be done. Follow these simple steps.
Press and hold Select button for 5 seconds to activate low level programming. Once activated, the display shows “LL” ad, I succession, the current preset low level configuration selected.
Press Change button repeatedly to select the same preset low level configuration again. Press Select to confirm. You will exit menu automatically. The in.xm.ce will then reset. After resetting, the system starts a “learning se-
quence” in which each individual output is activated and its peak current displayed and saved. Note: if unusual current readings, e.g. 4 to 6 amps are detected on high speed of any pump, all pumps must be primed, learning mode restarted.
37
W
IRING INSTALLATION
—EXPORT GUIDELINES IN.XE CE
INSTALLATION GUIDELINES for IN.XE CE
ALL
INSTALLATIONS AND CONNECTIONS ARE TO BE PERFORMED BY A QUALIFIED, LICENSED ELECTRICIAN ONLY AND IN ACCORDANCE WITH LOCAL REGULATIONS WITH THE HOME’S ELECTRICAL OUTPUT, AND FOLLOW THE GUIDELINES BELOW MAKING ANY ELECTRICAL CONNECTIONS
. I
DENTIFY THE CORRECT
.
CE
PLATFORM ON THE SPA UNIT, IN ACCORDANCE
. E
NSURE POWER IS TURNED OFF PRIOR TO
!
Warning!
This product must always be connected to a circuit protected by a residual-current device (RCD) having a rated operating residual-current not exceeding 30 mA. Proper wiring of the electrical service box, RCD and in.xe.ce terminal block is essential! Check your electrical code for local regulations. Only copper wire should be used, never aluminum.
IN.XE P
LATFORM CONTROL CENTER
1 x 230 VAC (1 x 32A) single phase,
or
1 x 230 VAC (2 x 16A) dual phase **
(available mid-2008)
Bonding lug
Correct wiring of the electrical service box, RCD protection device, and pack terminal block is essential!
Contact qualified, licensed electrician.
IN.XE.CE
(Single phase input Only; multi-phase not supported) 32 A absolute maximum, 50 Hz nominal.
ELECTRICAL SPECIFICATIONS
Input rating: 230 VAC nominal
:
** Contact your retailer for electrical specifications and connection instructions when this option becomes available.
In.XE CE 230 VAC Single phase ONLY
I
NITIAL START-UP
G
ENERAL GUIDELINES
38
1. BE
2. CAUTION: E
3. F
4. M
5. C
6. T
7. P
8. T
9.W
10.SET
11.THE
W
12. SET
13.C
14.C
SURE THAT THE POWER IS TURNED OFF AT THE MAIN CIRCUIT BREAKER
LECTRIC HEATER ELEMENT MUST BE FULLY SUBMERGED IN WATER BEFORE BEING ENERGIZED
ILL SPA TO THE RECOMMENDED LEVEL, ASSURING ALL SUCTION OUTLETS ARE COVERED WITH WATER
AKE SURE VALVES ON THE SUCTION AND RETURN SIDES OF THE SPA PUMP ARE OPEN TO ALLOW WATER TO
FLOW TO AND FROM THE SPA AND SPA SUPPORT SYSTEM
AREFULLY OPEN THE AIR BLEEDER VALVE FOUND ON THE TOP OF THE FILTER UNTIL WATER FLOWS OUT OF
THE TOP OF THE VALVE FITTING FROM THE TOP OF THE PUMP A FEW TURNS CONTINUE START-UP
URN POWER “ON” AT MAIN CIRCUIT BREAKER
RESS JET
URN ALL AIR REGULATOR KNOBS TO “OFF” POSITION
HEN THE SYSTEM HAS FULLY PRIMED, ALL THE JETS SHOULD BE FREELY ROTATING AND FREE OF EXCESS AIR
HEMICALLY TREAT THE SPA WATER
OVER THE SPA WITH THERMAL COVER TO MAINTAIN TEMPERATURE AND LOCK FOR SAFETY
/
PUMP BUTTON TO ACTIVATE CYCLE
EXCEPT THE JETS ATTACHED TO OZONE, IF THIS OPTION IS INCLUDED ON THE SYSTEM SYSTEM TO OPERATE FOR FIVE MINUTES IN THIS POSITION
THE THERMOSTAT TO THE DESIRED TEMPERATURE TO BEGIN HEATING THE SPA WATER
ICON ON THE SPA SIDE CONTROL WILL BE ON WHEN THE SPA IS HEATING
ECONOMICAL, GRADUAL HEATING OF THE WATER TAKES PLACE OVER A NUMBER OF HOURS, DEPENDING
UPON THE SIZE OF THE SPA, SIZE OF THE HEATER AND THE RECOMMENDED USE OF A
HEN THE DESIRED TEMPERATURE IS REACHED, NOT OVER THIS SETTING, THE TEMPERATURE WILL AUTOMATICALLY BE MAINTAINED TURE WITH AN ACCURATE THERMOMETER BEFORE ENTERING THE SPA
THE FILTRATION PROGRAM TO DESIRED SETTING PER INSTRUCTIONS FOUND IN THE CONTROL CENTER
SECTION OF THIS MANUAL
INSTRUCTIONS ON CONTAINER OF ANY PRODUCT USED
. C
.
LOSE VALVE
.
. R
EAD THE SECTION ON WATER CHEMISTRY MAINTENANCE AND FOLLOW
. IF
THE PUMP IS AIR-LOCKED, LOCATE PUMP
.
.
.
.
. A
FTER ABOUT
.
.
104˚F (40˚C).
.
#1,
LOOSEN RETURN
10
SECONDS, TIGHTEN UNION AND
. A
LLOW THE
. THE
INDICATOR
.
PDC
SPA COVER
LEAVE THE THERMOSTAT AT
. RE-
CHECK WATER TEMPERA
.
.
.
.
;
.
O
PERATION SYSTEMS
-600 S
39
ERIES CONTROL
WARNING: R
EAD ALL INSTRUCTIONS BEFORE USING THE SPA
. PDC Spas, PDC International assumes no responsibility for personal injury or property damage sustained by or through the use of this product. When installing and using this equipment basic safety precautions should always be taken to reduce risk of electrical shock, ensure safe usage, and safeguard the user’s health.
In.K 100 Partner Control
(optional) This control offers convenience of spa operation at a second location. Operates pumps 1,2,3, and light.
In.K 600 Series
Light Icon Pump Icons Blower Icon
Time, Temp, & Message Digits
Progress Bar Icon
Program Icon
Icon
Control Window and Icons
AM/PM (F/C)
Set Point icon
Service Icon
Smart Winter Mode Icon Filtering Icon Heating
Light Key “OK” Key Plus Key Program Key
Pump Keys Standby Key
Left Multi­function Key
Minus Key
Right Multi­function Key
Standby Mode
Use Standby key to pause pumps
Progress bar will display the re­maining time before the system automatically exits Standby mode (user can also exit Standby mode at any time by pressing again on
Pump 3 key
Press Pump 3 key to turn Pump 3 on at high speed.
Press a second time to turn pump off.
A built-in timer automatically turns pump off after 20 minutes, unless pump has been manually deactivated first.
In order to warn the user, the spa light will flash for a few seconds before the exit of Standby mode and restart the pumps. The "Stby" message is also displayed during Standby mode.
* Pump will stay turned on if there is a request for more heat.
Blower key
Press Blower key to turn blower on. Press a second time to turn blower
off. A built-in timer automatically turns
blower off after 20 minutes, unless blower has been manually deacti­vated first.
Pump 1 key
Press Pump 1 key to turn Pump 1 on at low speed. Press a second time to turn pump to high speed. Another press turns pump off.
A built-in timer automatically turns pump off after 20 minutes, unless pump has been manually deactivated first.
Light key
Press Light key to turn light on. Press a second time to turn light
off. Repeatedly turning on/off key toggles between color selections.
A built-in timer automatically turns light off after 2 hours, unless it has been manually deactivated first.
Pump 2 key
Press Pump 2 key to turn Pump 2 on at low speed. Press a second time to turn pump to high speed (with a dual speed pump). Press another time to turn pump off.
A built-in timer automatically turns pump off after 20 minutes, unless pump has been manually deactivated first.
+ / -
keys
Use (+) or (-) key to set desired water temperature. The tempera­ture setting will be displayed for 5 seconds to confirm your new selection.
The “set point” icon indicates that the display shows the desired temperature, NOT the current water temperature.
O
PERATION SYSTEMS
-600 S
40
ERIES CONTROL
Program key
Use Program key to display time or enter Programming menu by pressing , holding key.
In Programming mode, the following parameters can be set: time, filter cycle’s start time, duration, frequency, and the choice of temp. display units.
Filter cycle frequency
Press Ok key a fourth time. The display will show FFxx,
with "xx" representing the number of filter cycles per day (up to 4).
Use (+) or (-) key to change setting.
Setting the time
Enter Programming mode by holding Prog. key pressed down for 3 sec. The display will show the current time setting.
Setting hour: Use (+) or (-) key to change hour setting (AM/PM).
Setting minutes:Press Ok key. Use (+) or (-) key to change minutes setting.
Setting temperature unit
Water temperature can be displayed in either Fahrenheit (˚F) or Celsius (˚C).
• Press Ok key a fifth time.
• The display will show either ˚F or ˚C.
• Use (+) or (-) key to change setting.
• Press Ok key a last time to go back to normal mode.
Setting filter cycle start time
To program the filter cycle, enter these parameters: start time, dura­tion and frequency. During a filter cycle, pumps run for one minute to purge the plumbing, then Pump 1 low speed runs for the programmed number of hours.
Press Ok key a second time. The display will show FSxx, with "xx" representing the starting hour. Use (+) or (-) key to change setting (01:00- 12:00 AM/PM).
Smart Winter Mode
Our Smart Winter Mode protects your system from the cold by turning pumps on several times a day to prevent water from freezing in pipes.
Cooldown
While performing these tasks, the heater is not allowed to turn on and its icon flashes. The heater is not allowed also to come on throughout the cool down period of the heater element.
Setting filter cycle duration
Press Ok key a third time. The display will show Fdxx, with
“xx” representing the duration in hours. Use (+) or (-) key to change setting (0-12 hours).
Water temperature regulation
In a regulation cycle, the system first generates water flow through the heater housing and the plumbing, in order to ensure accurate water temperature readings as well as avoiding heater activation in dry condi­tions. After verifying pump activation and taking a water temperature reading if required, the system automatically turns the heater on to reach and maintain water temperature at Set Point.
O
PERATION SYSTEMS
- 400 S
41
ERIES CONTROL
WARNING: R personal injury or property damage sustained by or through the use of this product. When installing and using this equipment basic safety precautions should always be taken to reduce risk of electrical shock, ensure safe usage, and safeguard the user’s health.
EAD ALL INSTRUCTIONS BEFORE USING THE SPA
. PDC Spas, PDC International assumes no responsibility for
In.K 450 Series Control
Standard control for SE Series and AT Series spa units.
On/Off key
Key may have On/Off, Standby mode. Standby Mode: Use On/ Off key to pause all pumps. Progress bar ( XM platform only) will display the remaining time before the system auto­matically exits Standby mode (user can also exit Standby mode at any time by pressing again on On/Off key.
Pump 3/ Blower key
Press Pump 3/Blower key to turn Pump 3/Blower on. Press a second time to turn pump off. A built-in timer automatically turns pump off after 20 min­utes, unless pump has been manually deactivated first.
In order to warn the user, the spa light will flash for a few seconds before the exit of Standby mode and restart the pumps. The “Stby” message is also displayed during Standby mode.
Pump will stay turned on if there is a request for heat.
Light key
Press Light key to turn light on / light off. A built-in timer auto­matically turns light off after 2 hours, unless it has been manu­ally deactivated first.
Pump 1 key
Press Pump 1 key to turn Pump 1 on at low speed. Press a sec­ond time to turn pump to high speed (with a dual speed pump). A third time turns pump off. A built-in timer automatically turns pump off after 20 min­utes, unless pump has been
Up / Down keys
Press Up or Down key to set desired water temperature. The temperature setting will be displayed for 5 seconds to con­firm your new selection. The “Set Point” icon indicates that the display shows the desired tem­perature, NOT the current water temperature.
Pump 2 key
Press Pump 2 key to turn Pump 2 on at low speed. Press a sec­ond time to turn pump to high speed (with a dual speed pump). Pressing a third time turns pump off. A built-in timer automati­cally turns pump off after 20 minutes, unless pump has been manually deactivated first.
Program key
Use Program key to display time or enter Programming menu by pressing and holding key. In Pro­gramming mode, these parame­ters can be set: time, filter cycle start time, filter cycle duration, filter cycle frequency, tempera­ture unit. Note:Light key used as Program key if key not present.
O
PERATION SYSTEMS
In.K 450 Series Control
Standard control for SE Series and
AT Series spa units.
- 400 S
ERIES CONTROL
Setting the time
Enter Programming mode by holding Prog. Key pressed down for 3 sec. The display will show the current time setting. Setting the hour: Use Up or Down arrows to change the your setting (AM/PM). Setting the minutes: Press Prog. Key a second time. Use Up or Down key to change minutes setting.
42
Setting filter cycle start time
To program the filter cycle, you must enter these parameters; the start time, duration and frequency. During a filter cycle, pumps run for one minute to purge the plumbing, then Pump 1 runs for the pro­grammed number of hours. Press Prog. Key a third time. The display will show FSxx, with “xx” repre­senting the starting hour. Use Up or Down key to change setting.
Setting filter cycle duration
Press Prog. key a fourth time. The display will show Fdxx, with “xx” representing the duration in hours.
Use Up or Down key to change setting.
Filter cycle frequency
Press Prog. key a fifth time. The display will show FFxx, with “xx” representing the number of filter cycles per day (up to 4).
Use Up or Down key to change setting.
Setting temperature unit
Water temperature can be displayed in either Fahrenheit (“F) or Celsius (“C). Press Prog. Key a sixth time. Display shows either “F or “C.
Use Up or Down key to change setting.
Cooldown
While performing these tasks, the heater is not allowed to turn on and its icon flashes. The heater is not allowed also to come on throughout the cool down period of the heater element.
Water temperature regulation
In a regulation cycle, system first generates water flow through the heater housing and the plumbing, to ensure accurate water tempera­ture readings, as well as avoiding heater activation in dry conditions.
After verifying pump activation and taking water temperature read­ing if required, the system auto­matically turns heater on to reach and maintain water temperature at Set Point.
Smart Winter Mode
Our Smart Winter Mode protects your system from the cold by turning pumps on several times a day to prevent water from freezing in pipes.
W
ATER CHEMISTRY GUIDELINES
WATER CHEMISTRY MAINTENANCE
P
H C
ONTROL
C
1. THE
2. T
3. T
THE
:
HEMICALLY BALANCED WATER DEPENDS PRIMARILY ON
AMOUNT OF ACID OR BASE IN THE WATER (P HOSE CHEMICALS THAT HELP MAINTAIN OR STABILIZE P HOSE CHEMICALS THAT CAUSE SCALING (CALCIUM HARDNESS
OF RELATIVE ACIDITY OR ALKALINITY OF WATER, PH IS MEASURED ON A NUMBER SCALE FROM
MID-POINT SIVELY GREATER AND BELOW WHICH ACIDITY BECOMES PROGRESSIVELY GREATER SPA WATER SHOULD HAVE A PH BETWEEN OPTIMUM RANGE OF CHEMICALS AND FILTERING FUNCTIONS WILL BE MOST EFFECTIVE MEASURE THE PH AND SHOULD BE REPLACED ON AN AT LEAST ANNUAL BASIS TO ASSURE ACCURACY
, 7, IS
SAID TO BE PRECISELY NEUTRAL, ABOVE WHICH ALKALINITY BECOMES PROGRESS
100-400
PPM OF CALCIUM HARDNESS
D
ISINFECTION
THE
B
B
THE
T
C
REMEMBER!:
1. B
2. A
3. N
4. M
5. THE
:
HIGH TEMPERATURE AND INCREASED VELOCITY OF THE WATER, AS WELL AS THE HEAVY BATHER LOADS, ALL CONTRIBUTE TO THE ORGANIC CONTAMINATION OF SPA WATER TANT TO MAINTAIN AN EFFECTIVE RESIDUAL OF SANITIZING AGENT, TO SHOCK TREAT AT PERIODIC INTERVALS AND, IF NEEDED, TO CONTROL ALGAE GROWTH
ROMINE IS THE BEST-SUITED SANITIZER FOR SPA WATER A SWIMMING POOL SANITIZER, THE HIGH TEMPERATURES AND AERATION OF A SPA GREATLY ACCELERATE CHLORINE LOSS WHICH IS A POOR DISINFECTANT THAT CAUSES OFFENSIVE ODORS AND OFTEN CAUSES EYE BURN
ROMINE IS SIMILAR TO CHLORINE, ALTHOUGH IN THE FREE AND COMBINED FORM IT IS AN EFFECTIVE SANITIZING AGENT AND CAUSES NO OFFENSIVE ODOR OR EYE BURN BROMINE RESIDUAL THAN CHLORINE AND IT IS EFFECTIVE OVER A WIDER PH RANGE THAN CHLORINE
LOAD, AMOUNT OF USAGE, TYPE OF WATER, ULTRAVIOLET EXPOSURE, ETC NEEDED WILL VARY ORGANIC CONTAMINATION NOT READILY DESTROYED BY NORMAL ADDITIONS OF THE SANITIZING AGENT
HIS IS ACCOMPLISHED BY USING A POWERFUL, LONG-LASTING OXIDIZING AGENT CAPABLE OF DESTROY ING THE ORGANIC CONTAMINANTS SO THE SANITIZER CAN BE EFFECTIVE IN KILLING BACTERIA
THE LINE OF CHEMICALS BEING USED GROWTH MAY BE A PROBLEM FOR ADVICE ON THE BEST AGENT AVAILABLE TO HANDLE THIS PROBLEM
DISTRIBUTED OVER THE SURFACE OF THE WATER, OR POURED INTO THE WATER, PREFERABLY WITH THE PUMP AND BUBBLER ON
FACTOR FOR BATHERS AND IS HELPFUL IN CONTROLLING WATER PROBLEMS
OF TESTING CHEMICAL LEVELS AND MAINTAINING THEM
. F
REE CHLORINE REACTS WITH ORGANIC MATERIALS TO FORM COMBINED CHLORINE
TEST FOR BROMINE SHOULD READ
. ON A
WEEKLY BASIS, A “SHOCK” TREATMENT SHOULD BE USED TO DESTROY
ONTACT YOUR CHEMICAL SUPPLIER FOR THE BEST “SHOCKING” AGENT IN CONJUNCTION WITH
. IF
EFORE USING CHEMICALS, READ THE LABELS AND FOLLOW DIRECTIONS CAREFULLY LWAYS ADD THE CHEMICALS DIRECTLY TO THE SPA WATER, EITHER IN A SUITABLE FEEDER
.
EVER ADD CHEMICALS TO THE SPA WHILE PEOPLE ARE USING IT
AINTAINING TEMPERATURE BETWEEN
BOTTOM LINE TO PROPER WATER MAINTENANCE IS TO ADHERE TO A REGULAR SCHEDULE
34
7.2-7.8, A
. FOR
SPAS INSTALLED OUTSIDE AND DIRECTLY IN SUNLIGHT, ALGAE
THIS OCCURS
:
H),
H (
TOTAL ALKALINITY) AND
). D
ESCRIBED AS A MEASURE
,
0 - 14.
. P
ROPERLY BALANCED
TOTAL ALKALINITY OF
. W
ITHIN THESE LIMITS, YOUR SANITIZING
. T
75-150
EST KITS ARE AVAILABLE TO
PPM AND AN
. IT IS
VERY IMPOR
.
. A
LTHOUGH CHLORINE IS POPULAR AS
.
. IT IS
1
PPM IN A RESIDENTIAL SPA
EASIER TO MAINTAIN A
. D
EPENDING UPON BATHER
.,
THE AMOUNT OF CHEMICALS
.
,
CONTACT YOUR RETAILER OR CHEMICAL MANUFACTURER
.
.
.
95-104°F (35-40°C) IS
ESSENTIAL AS A HEALTH
.
.
.
,
.
.
,
W
ATER CHEMISTRY GUIDELINES
(
CONT’D
44
.)
WATER CHEMISTRY MAINTENANCE
O
ZONE
Y
24-
1. T
2. A
3.
:
OUR SPA MAY BE EQUIPPED WITH OZONE AS THE SANITIZING AGENT SPAS AND OPTIONAL ON THE
HANDS-FREE” ROUTINE TO SPA WATER CARE NEEDED AFTER HEAVY BATHER LOADS NEEDED LESS FREQUENTLY, AND THE BROMINE ODOR NO LONGER AN ISSUE
HOUR CIRCULATION IS REQUIRED TO EFFECTIVELY SANITIZE THE WATER, AND A CHLORINE SHOCK
USED PERIODICALLY
HERE IS NO TEST KIT AVAILABLE TO TEST OZONE PRESENCE IN SPA WATER, ALTHOUGH A
CIRCULATION PERIOD IS RECOMMENDED FOR CLEAN, CLEAR WATER SMELL WILL BE PRESENT WHEN YOU OPEN YOUR SPA COVER AS AN INDICATOR THAT THE OZONE IS DOING IT’S JOB
PROPER PH MUST BE MAINTAINED AND A ROUTINE BROMINE OR CHLORINE SHOCK IS SUGGESTED
THE OZONE SYSTEM WITH YOUR SPA HAS AN EVERLITE INDICATOR MOUNTED ON THE CORNER OF THE SPA CABINET BE LIT WHEN UNIT IS IN FILTRATION CYCLE FURTHER INSTRUCTIONS
O
ZONE UNIT
. T
. C
HIS EMITS A BLUE LIGHT WHEN THE OZONE UNIT IS FUNCTIONING
SE S
ONTACT YOUR CHEMICAL SUPPLIER FOR MORE INFORMATION
.
.
Location varies with spa model. Refer to specifications for location and take note during installation positioning.
(cont’d.)
ERIES UNITS
. W
. S
TANDARD ON THE
. T
HIS UTILIZES ULTRAVIOLET LIGHT AND OFFERS A
. THE PH
ITH THE USE OF OZONE, THE PERIODIC DRAINING MAY BE
MUST BE MAINTAINED AND SHOCKING MAY BE
. IT IS
SUGGESTED THAT
. A
CLEAN
. E
. R
EFER TO CONTOL INFORMATION AND ICON CHART FOR
LX S
.
24-
, “
AFTER RAIN
VERLITE WILL ONLY
ERIES
HOUR
.
PROBLEM
Green Algae
Black Algae
Unpleasant Odor,
Burning Eyes
Colored Water
Hard Water
BASIC WATER CHEMISTRY CHART
Green Water
DESCRIPTION
Green spots on surface Slippery surface
Black spots on spa surface
Chlorine-like odor. Burning sensation in eyes.
Water in newly-filled spa turns black, blue, or brown when treated with ozone
Cloudy water Scaling
Low ozone, bromine, or chlorine levels
CAUSE
Low algaecide levels
Low oxidizer levels Low algaecide levels.
Combined chlorine and/or pH out of
balance
Copper, iron, or manganese in water being oxidized by chlorine or ozone
Excessive hardness of makeup water or building up of dissolved minerals in the water caused by continued use of spa chemicals.
Superchlorinate
REMEDY
Brush spa; removing algae Vacuum spa; removing algae Increase oxidizer residual
Superchlorinate Brush spa; removing algae Vacuum spa; removing algae Increase oxidizer residual
Superchlorinate. Balance pH to 7.2-7.6
Adjust pH to 7.2-7.6 Run filter continuously Vacuum settled material Use sequestering agent for prevention
Clean filter Filter continuously Adjust pH to 7.2-7.6 Use scale inhibitor Dilute with makeup water
45
M
AINTENANCE
T
ESTING THE
G
USE BY THE HOMEOWNER PANEL BOX OR ON THE POWER CORD SHOULD RETURN TO NORMAL OPERATION OF ELECTRICAL SHOCK
D
IDENTIFICATION AND CORRECTION OF THE PROBLEM
THE SPA S
TO
ALCOHOL CLEANSER, CONSULT YOUR DEALER
C
EDAR CABINET
W
LOSE ITS NEW APPEARANCE ING WITH FINE-GRIT SANDPAPER WILL HELP SMOOTH ANY ROUGHNESS, AND REGULAR APPLICATIONS OF A PENETRATING WOOD PRESERVATIVE WILL ENHANCE AND PROTECT THE RICHNESS OF WOOD
P
ERMA-WOOD CABINET
Y
AND VIRTUALLY MAINTENANCE-FREE
THE C
U
YOUR OPERATING COSTS, HEAT-UP TIME AND MAINTENANCE REQUIREMENTS IT WITH CARE AND CLEAN IT REGULARLY USING MILD SOAP AND WATER TIONER WILL HELP PROTECT AGAINST DETERIORATION CAUSED BY STAND OR SIT ON THE COVER, AND AVOID DRAGGING IT ACROSS ROUGH SURFACES
THE F
SPA
PRESSURIZED FILTER ASSURES OPTIMUM CLEANING CAPACITY WATER, THE ACCUMULATED DEBRIS WILL CAUSE A RESISTANCE TO FLOW WATER, CLEAN OR REPLACE THE FILTER ELEMENT AS NOTED BELOW
1. S
2. O (BE
3. D
ROUND FAULT CIRCUIT INTERRUPTER
ISCONTINUE SPA OPERATION BY DISCONNECTING THE POWER SOURCE AND NOTIFY A QUALIFIED ELECTRICIAN FOR
URFACE
PRESERVE THE SHEEN OF YOUR SPA’S SURFACE, CLEAN AND SANITIZE THE ACRYLIC SURFACE WITH RUBBING
. A
VOID USING ABRASIVE CLEANSERS
OOD CEDAR CABINET
OUR SPA MAY BE CONSTRUCTED FROM A WOOD ALTERNATIVE MATERIAL DESIGNED TO BE DURABLE, TOUGH
OVER
SING THE OPTIONAL INSULATING SPA COVER ANYTIME THE SPA IS NOT IN USE WILL SIGNIFICANTLY REDUCE
ILTER
WATER FILTRATION BEGINS AS SOON AS THE FLOW IS STEADY THROUGH THE PUMP
HUT OFF POWER AT THE MAIN OR SUB PANEL
PEN THE SMALL, BLACK BLEEDER VALVE ON TOP OF THE FILTER COVER SLIGHTLY TO RELEASE PRESSURE
SURE TO RE-CLOSE THE VALVE SNUGLY BEFORE REACTIVATING THE SPA
EPRESS SAFETY TAB NEXT TO THE LID AND REMOVE THE BLACK LOCK RING THE FILTER ELEMENT CLEANSING SOLUTION AVAILABLE FROM YOUR SPA RETAILER HOSE OR PRESSURE HOSE, AND REPLACE IN THE FILTER HOUSING CARTRIDGE ON HAND SO THAT A CLEAN ELEMENT WILL ALWAYS BE AVAILABLE WHILE THE SOILED ELEMENT IS BEING CLEANED REPLACING THE ELEMENT INTO THE HOUSING, BE SURE THAT THE O-RING IS IN PLACE AND CLEAR TO ASSURE A SNUG FIT OF THE FILTER DOME LID TO PREVENT LEAKAGE CLICKS INTO PLACE
(
1. S
2. R
3. L
4. R
5. R
6. P
6. P
HUT OFF POWER AT THE MAIN OR SUB PANEL
EMOVE THE FILTER HOUSING TOP BY USING THE RAISED PORTIONS OF THE FILTER TOP AND TURNING IT
COUNTER CLOCKWISE
IFT THE SKIMMER BASKET OUT OF THE FILTER CANISTER
EMOVE THE FILTER FROM THE CANISTER
EPLACE WITH CLEAN FILTER LACE SKIMMER BASKET BACK IN FILTER CANISTER LACE FILTER TOP ONTO FILTER CANISTER AND TURN CLOCKWISE UNTIL TOP STOPS
R
ECOMMENDATIONS
G.F.C.I. (
EQUIVALENT
RCD
FOE EXPORT INSTALLATIONS
(G.F.C.I.)
. W
ITH THE SPA IN OPERATION, PUSH THE “TEST” BUTTON ON THE
. THE
SPA SHOULD SHUT DOWN IMMEDIATELY
. IF
THE
G.F.C.I.
.
. IF
YOU ARE NOT CERTAIN AS TO THE SUITABILITY OF A PARTICULAR
. DO
NOT USE SOAP, AS IT CAN CAUSE SUDSING
: W
ITH TIME AND EXPOSURE TO THE ELEMENTS, THE WOOD ON YOUR SPA WILL TEND TO
. P
ROTECTING OR REVIVING THE WOOD SURFACES IS A FAIRLY SIMPLE
:
. IT
MAY REQUIRE PERIODIC CLEANING WITH A NON-ABRASIVE CLEANER
(
TOP-LOAD PRESSURIZED SYSTEM ON
. C
LEAN ANY DEBRIS FROM THE FILTER HOUSING
. T
HIS WILL MINIMIZE DOWNTIME OF THE SPA DURING THE CLEANING PROCEDURE
. RE-
CHECK BLEEDER VALVE TO BE SURE IT IS CLOSED
SUCTION-SIDE SYSTEM ON SUNRISE AND
. A
FTER TOP STOPS TURNING, LIFT UP TO REMOVE TOP FROM FILTER
( R
EVIEW ABOVE FOR CLEANING RECOMMENDATIONS
)
PROTECTION FOR THE SPA SHOULD BE TESTED PRIOR TO EACH
G.F.C.I.
. NOW
RESET THE
FAILS TO OPERATE IN THIS MANNER, THERE EXISTS A POSSIBILITY
.
.
.
. TO
PROLONG THE LIFE OF THE COVER, HANDLE
. P
ERIODIC TREATMENTS WITH A VINYL CONDI-
UV
LX, SE S
. AS
RAYS FROM THE SUN
. K
ERIES UNITS
THE FILTER CARTRIDGE REMOVES DIRT FROM THE
)
. W
HEN THIS IS NOTICED, ALONG WITH CLOUDY
. N
EEP COVER LOCKED WHEN NOT IN USE
.
.
.)
. L
IFT THE DOME LID AND REMOVE
. S
OAK THE FILTER ELEMENT IN A FILTER
. R
INSE THE FILTER ELEMENT DOWN WITH A GARDEN
. (IT IS
RECOMMENDED TO HAVE AN EXTRA FILTER
. H
AND TIGHTEN THE LOCK RING UNTIL THE SAFETY TAB
.
AT S
ERIES UNITS
)
.
.
.
.
BREAKER AT THE
G.F.C.I. THE
PROCESS
EVER ALLOW ANYONE TO
. THE
TOP LOAD
.) W
.
.)
.
SPA
. L
IGHT SAND-
.
HEN
.
,
,
.
46
M
AINTENANCE
P
ERIODIC SPA WATER DRAINING
A
NATE ODORS IN THE SPA ALLY, DEPENDING UPON BATHER LOAD AND WATER CHEMISTRY MAINTENANCE, THIS MAY NEED DONE EVERY MONTHS
1. R
2. T
3. C
(SEE
4. C
5. C
6. F
FTER A CERTAIN TIME, YOU MAY FIND THAT THE ADDITION OF CHEMICALS WILL NOT CLARIFY OR ELIMI-
. W
ITH THE USE OF OZONE, THIS MAY NEED DONE LESS FREQUENTLY
R
ECOMMENDATIONS
. T
HIS IS AN INDICATION THAT THE WATER NEEDS TO BE DRAINED AND REPLACED
.
EDUCE SET TEMPERATURE TO
URN OFF ALL POWER
ONNECT A GARDEN HOSE TO THE RECESSED DRAIN VALVE FOUND ON THE SIDE OF YOUR SPA
CABINET, BY SLOWLY PULLING THE CAP OUT ALL THE WAY (APPROXIMATELY TURN CAP COUNTERCLOCKWISE TO REMOVE THIS WILL START THE DRAINING PROCESS AND PUSH THE VALVE ALL THE WAY IN
PHOTO
NUT AROUND THE DRAIN VALVE TO REMOVE THE CABINET PANEL FROM THE SPA FOR SERVICING, IF NECESSARY
LEAN CARTRIDGE FILTER AS NOTED PREVIOUSLY
IN THIS SECTION REGARDING MAINTENANCE RECOMMENDATIONS
LEAN SPA SHELL WITH NON-SUDSING CLEANSER
OLLOW INSTRUCTION UNDER START-UP
.) N
.
OTE
59˚F (15˚C).
: U
NSCREW THE LARGE
.
.
.
. A
TTACH THE HOSE AND PUSH VALVE
. A
FTER DRAINING THE SPA, REPLACE THE CAP
.
.
. G
2”)
ENER-
3
AND
1”,
P
LUMBING CARE
ALL
PLASTIC PARTS AND THEIR MANY GLUE JOINTS ARE SUBJECTED TO HARSH TREATMENT WATER TO ASSURE THERE ARE NO LEAKS WHEN IT LEAVES THE FACTORY; HOWEVER, SOMETIMES SPAS DEVELOP A LEAK CAUSED BY SHIPPING VIBRATION AND THE HIGH PRESSURE GENERATED BY THE POWERFUL JET PUMP, WHICH TOGETHER STRESSES THE PIPES AND JOINTS
. PDC
PORTABLE SPA WHICH ALLOW QUICK AND THOROUGH INSPECTION AND REPAIR OF THE PLUMBING SYSTEM A LEAK OCCUR, FOLLOW THESE INSTRUCTION TO MAKE THE REPAIR
1. R
2. T
3. C
R
EPLACING THE LIGHT BULB
IF
BURN OUT YOU WILL NEED TO REMOVE THE ACCESS PANEL TO REPLACE IT
ING REMOVAL
BE
SURE THE POWER IS “OFF HOUSING, TURN THE HOUSING COUNTERCLOCKWISE AND REMOVE FROM SPA SHELL BULB, PULL THE OLD BULB FROM THE HOUSING AND INSERT NEW ONE TO SPA SHELL
(SEE
THE UNDERWATER LIGHT BULB SHOULD
( M
.
ILLUSTRATIONS
SPAS ARE PLUMBED WITH PLASTIC JETS, PIPES AND FITTINGS WHICH ARE GLUED TOGETHER
. E
VERY SPA IS TESTED WITH
. O
VER THE YEARS, YOUR SPA IS SUBJECTED TO MANY HOT-COLD CYCLES
SPAS ARE DESIGNED TO BE OWNER SERVICEABLE WITH EASY-ACCESS PANELS ON ALL
EMOVE SIDE PANEL TO LOCATE LEAK
URN OFF ALL POWER
ONTACT QUALIFIED SERVICE TECHNICIAN TO REPAIR PLUMBING
. D
RAIN SPA BELOW LEAK, ALLOW PLASTIC PARTS TO DRY
. M
.
ARK THE LEAK WITH A MARKING PEN
.
4
.
OOD LIGHT
(R
EFER TO THE MANUAL SECTION REGARD-
).
. R
EPLACE CABINET PANEL AND ENDS
/ M
OTION GLOW LIGHTING
”. L
OCATE THE LIGHT
. TO
REPLACE THE
. RE-
ATTACH THE LIGHT HOUSING
)
)
.
. T
HESE
SIDES OF THE
. S
HOULD
.
W
INTERIZING YOUR HOT TUB
47
IF
FREEZING EXISTS, CERTAIN PRECAUTIONS SHOULD BE TAKEN TO AVOID DAMAGE CYCLE, AND USE OF A RIGID FOAM COVER ARE SUGGESTED
YOUR SPA IS TO BE USED DURING THE WINTER MONTHS IN COLD CLIMATE WHERE THE DANGER OF
. AN
INCREASED CIRCULATION
. C
ONTACT YOUR DEALER FOR ADVICE
.
M
CERTAINLY SUGGESTS THE USE OF A SPA YEAR-ROUND, ALTHOUGH CERTAIN SITUATIONS DO REQUIRE CLOSING THE UNIT FOR THE WINTER MONTHS (I.E.,VACATION HOMES PERFORM THE FOLLOWING WINTERIZING PROCEDURES
ANY SPA OWNERS FIND THAT OUTDOOR WINTERTIME SOAKING IS QUITE ENJOYABLE, AND
). IF
THE SPA WILL NOT BE USED FOR A PERIOD OF TIME
:
PDC
1. T
URN HEAT ALL THE WAY DOWN AND TURN OFF AT THE BREAKER
.
2. D
RAIN SPA OF ALL WATER
.
3. R
EMOVE ANY REMAINING WATER WITH SPONGE
.
4. TO AIR’
5. F
REMOVE WATER FROM THE AIR CHANNEL; THE
ASSAGE DESIGN, TURN POWER BACK ON SEVERAL MINUTES TO SPRAY OUT WATER NECESSARY
ILTER SHOULD BE DRAINED, REMOVED AND CLEANED
. S
HUT OFF ALL ELECTRICAL POWER TO UNIT
LX S
. W
ERIES SPAS EQUIPPED WITH THE
. T
URN
“B
UBBLER” ON FOR
IPE OUT SPA AND REPEAT AS
.
. S
TORE IN A DRY PLACE
.
6. P
UMP, MOTOR AND ALL CONNECTING LINES SHOULD BE DRAINED FULLY TO PROTECT
FROM FREEZING WATER
. YOU
GUARANTEE FREEZE PREVENTION INSTRUCTIONS AND REMOVE ALL ANTI-FREEZE BEFORE THE NEXT SPA USE
. B
LOW AIR THROUGH ALL CONNECTION LINES TO REMOVE
MAY WISH TO USE A NON-TOXIC
. BE
SURE TO READ THE MANUFACTURER’S
RV
TYPE ANTIFREEZE TO
7. C
OVER THE SPA WITH A WATERPROOF RIGID COVER TO PROTECT IT FROM SNOW, ICE
AND WIND
.
,
.
T
ROUBLESHOOTING
48
A
QUENTLY TAILER
IF
YOUR SPA IS NOT OPERATING, CHECK THE FOLLOWING
GOOD GENERAL RULE IS TO VISUALLY INSPECT YOUR SPA AND EQUIPMENT AREA FRE-
. IF
. A
SIMPLE REPAIR MAY PREVENT AN INJURY OR MORE SERIOUS PROBLEMS REQUIRING EXPENSIVE REPAIRS
ANYTHING LOOKS BROKEN, WORN, OR INCORRECT, CONTACT YOUR ELECTRICIAN OR SPA RE-
:
1. ALL
C
C
C
C
EQUIPMENT IS IN-OPERATIVE
HECK POWER SOURCE HECK TO ASSURE SPA HAS DEDICATED CIRCUIT HECK THE “TEST” AND “RESET” BUTTONS ON HECK INTERNAL FUSES
G.F.C.I.
.
BREAKER
. (OR
EQUIVALENT
.
G.F.C.I. (OR
)
EQUIVALENT
)
2. P
C
C
C
P
UMP DOES NOT WORK
HECK ALL ITEMS ABOVE HECK FILTER; CLEAN OR REPLACE CARTRIDGE HECK FOR BLOCKAGES (RESTRICTIONS) AT SUCTIONS, SKIMMER AND PUMP
USH “PUMP” BUTTON(S) TO CHECK IF HIGH SPEED IS FUNCTIONING, ON A DUAL-SPEED PUMP
.
.
.
3. I
M
M
C
C
P
C
NADEQUATE JET ACTION
AKE SURE JETS ARE TURNED ON
AKE SURE AIR CONTROLS ARE OPEN HECK FOR RESTRICTIONS (BLOCKAGES) IN JETS AND/OR MAIN SKIMMER AND PUMP HECK WATER LEVEL
USH “PUMP” BUTTON(S) TO CHECK IF HIGH SPEED IS FUNCTIONING ON A DUAL-SPEED PUMP
HECK TO BE SURE THE ULTRA MASSAGE SELECTOR (DIVERTER VALVE) IS IN CENTER
POSITION
.
(
STANDARD ON
.
.
.
LX S
ERIES SPAS
.)
4. NO
C
C
C
C
C
HEAT
HECK ALL STEPS UNDER PART HECK TEMPERATURE SETTINGS HECK FOR CLOGGED FILTER ELEMENT AND OTHER RESTRICTIONS HECK WATER LEVEL HECK IF PUMP IS RUNNING
.
“1”.
.
.
.
5. NO
• C
B
BUBBLER
HECK ALL STEPS UNDER PART LOWERS GENERALLY NEED NO MAINTENANCE
“1”.
. R
EPLACEMENT IS NORMALLY THE SOLUTION
6. NO
C
C
LIGHT
HECK “LIGHT” BUTTON HECK
G.F.C.I. (OR
.
EQUIVALENT
) “
TEST” AND “RESET” BUTTONS
.
7. W
I
T
C
ATER IS CLOUDY
NCREASE CIRCULATION CYCLE
EST WATER CHEMISTRY
LEAN/REPLACE FILTER CARTRIDGE
.
.
.
8. P
T
UMPS HAVE STARTED FOR
HIS IS A FEATURE OF THE SMART WINTER MODE PROTECTING YOUR SPA FROM THE COLD BY
TURNING PUMPS ON FOR
1
MINUTE SEVERAL TIMES
1
MINUTE SEVERAL TIMES A DAY TO PREVENT FREEZING IN PIPES
IF
ABOVE CHECKS DO NOT SOLVE THE PROBLEM, CONTACT A QUALIFIED SERVICE TECHNICIAN
.
.
.
.
.
.
.
R
ECORDS AND CONTACT INFORMATION
ELECTRICIAN
C
OMPANY NAME
C
ONTACT NAME
A
DDRESS
P
HONE
, E-
MAIL ADDRESS
BUILDER, MASON
C
OMPANY NAME
C
ONTACT NAME
A
DDRESS
P
HONE
, E-
MAIL ADDRESS
49
SERVICE TECHNICIAN
C
OMPANY NAME
C
ONTACT NAME
A
DDRESS
P
HONE
, E-
MAIL ADDRESS
GENERAL NOTES
_______________________________________________________________
_______________________________________________________________
_______________________________________________________________
_______________________________________________________________
_______________________________________________________________
_______________________________________________________________
! SAVE THIS MANUAL FOR FUTURE REFERENCE !
75 P
ALMER INDUSTRIAL ROAD
W
ILLIAMSPORT
570-323-3060
WWW.PDCSPAS.COM
, PA 17701 USA
TEL
570-323-8485
FAX
75 Palmer Industrial Road
Williamsport, Pennsylvania 17701
USA
1.800.451.1420 tel
1.570.323.8485 fax
www.pdcspas.com www.pdcspasinternational.com
Loading...