PCRmax Microplate Sealer Instruction Manual

Microplate Heat Sealer, Variable Temperature
13204-01
Instructions for Use
2
Contents
1 Symbols Used in this Instruction Manual ......................................................... 3
2 Safety Precautions and Limitations of Use ...................................................... 4
3 Regulatory Limitations of Use .......................................................................... 8
4 Unit Description ............................................................................................... 9
5 Unit Installation .............................................................................................. 11
6 Unit Operation ................................................................................................ 13
6.1 User Display and Controls ............................................................................. 13
6.2 Performing a Sealing Operation .................................................................... 14
6.3 Switching Off the Audible Alert ...................................................................... 16
7 Maintenance and Servicing............................................................................ 17
7.1 Replacing the Unit Fuse ................................................................................ 17
7.2 Overtemperature Safety Cut-out .................................................................... 18
7.3 Routine Cleaning and Inspection ................................................................... 18
7.4 Decontamination Procedure .......................................................................... 19
7.5 Transportation and Storage ........................................................................... 20
7.6 Product Disposal ............................................................................................ 20
8 Warranty and Returns .................................................................................... 21
9 Technical Specifications ................................................................................ 22
10 Glossary of Terms and Abbreviations ............................................................ 23
Tables
Table 1: Advisory Symbol Meanings ......................................................................... 3
Table 2: Unit Features ............................................................................................... 9
Table 3: Plate and Adapter Types ........................................................................... 10
Table 4: Recommended Film and Foil Types .......................................................... 10
Table 5: Mains Voltage Selection ............................................................................ 11
Table 6: User Buttons and Status LEDs .................................................................. 13
Microplate Heat Sealer
Instructions for Use
3
1 Symbols Used in this Instruction Manual
The following advisory symbols are used in this manual.
Table 1: Advisory Symbol Meanings
DANGER
Indicates a Risk of Electric Shock which could, if not avoided, result in serve injury or death.
DANGER
Indicates a Burn Hazard which could, if not avoided, result in serve injury or death.
DANGER
Indicates a Risk of Explosion which could, if not avoided, result in serve injury or death.
WARNING
Indicates a hazardous situation which could, if not avoided, result in serve injury or death; or severely damage the unit.
CAUTION
Indicates a hazardous situation which could, if not avoided, result in minor or moderate injury; or degrade or impair the functionality of the unit.
CAUTION
Indicates a Risk of Crush hazard due to moving parts which could, if not avoided, result in minor or moderate injury.
Advisory note or other useful information.
NN
Refer to “section NN” for more details.
4
2 Safety Precautions and Limitations of Use
It is essential that all users of this equipment have fully read and understood the following safety precautions and limitations of use before installing or operating the Microplate Heat Sealer unit.
IMPORTANT
WARNING
The protection provided by this equipment may be impaired if it is not used in a manner described in this manual.
WARNING
It is essential that the user of this equipment is aware of the potential hazards associated with the unit and its accessories.
All operators should be familiar with the safety precautions and warnings given in these instructions before attempting to operate the unit.
Improper use of this unit or its accessories may impair their functionality and invalidate the manufacturer’s warranty.
Unit Handling Precautions
CAUTION
Care should be taken not to drop the unit or subject it to rough physical handling, both during normal use and during transportation and storage.
WARNING
The unit should be held by the handle when being lifted or moved. Do not lift the unit by any other part of the casework.
Care should be taken when lifting the unit due to its weight.
CAUTION
Care should be taken not to knock the LED display. Do not use excessive force when pressing the control buttons
or operating the seal activation handle.
Microplate Heat Sealer
Instructions for Use
5
Unit Installation and Operating Environment
DANGER
WARNING
The Microplate Heat Sealer unit is designed for indoor laboratory use only.
The acceptable operating temperature range is 18ºC to 30ºC, with a relative humidity of 20% to 80% non-condensing, at a maximum altitude of 2200m above sea level.
If the unit is stored in conditions outside of these ranges, it must be left to stand unpowered until it has acclimatised to within these environmental limits before being powered.
DANGER
Use only the AC mains power cord provided with the unit or as specified section 9.
The unit must be connected to a suitably earthed mains supply, with appropriate earth-leakage and over-current protection.
WARNING
Always ensure that the mains power connector is securely inserted into the rear of the unit, and any excess power cord does not pose a potential trip or pull hazard.
DANGER
Do not operate the unit in any area which is, or has been, or is thought to have been exposed to explosive or flammable gases, vapours or liquids.
WARNING
The unit must be installed and operated on a solid, stable and level working surface; ensuring that the ventilation holes at the rear of the unit are not obstructed.
6
General Operating Precautions
DANGER
Ensure that the power is switched off at both the AC mains supply outlet and at the back of the unit before inserting or removing the mains power cord.
DANGER
The heater plate can reach temperatures of 200ºC and will remain hot for a considerable time after being turned off.
Extreme care must be taken not to touch the heater plate as it will cause a serve burn injury.
DANGER
The unit is intended for use with plates containing biological samples only.
Never use the unit to seal any explosive, volatile or highly reactive substances or chemicals.
CAUTION
There is a possible finger crush hazard due to the moving parts of the handle and plate carrier.
Care should be taken when operating the handle.
Microplate Heat Sealer
Instructions for Use
7
Unit Maintenance and Serviceability
DANGER
WARNING
There are no user or operator serviceable parts inside the unit.
Do not remove the unit casework.
Removal of the unit's casework will void the manufacturer’s
warranty and may expose the user to a Risk of Electric Shock resulting in serious injury or death.
DANGER
Once installed, the externally accessible unit fuse will only blow under a fault condition. This fuse should only be changed after the unit has been thoroughly inspected by a qualified engineer. See section 7.1 for details.
DANGER
Always switch off the unit and disconnect the power cord before performing any cleaning or decontamination procedure.
If liquid is spilt into or over the unit, switch off and disconnect the power from the AC mains outlet before attempting to deal with the spillage.
CAUTION
Ensure that the heater plate has cooled down to room temperature before performing any cleaning operation and before moving or storing the unit.
CAUTION
The use of harsh chemicals and cleaning agents may damage the unit and degrade its performance.
Always follow the cleaning and decontamination procedures specified in sections 7.3 and 7.4 of this instruction manual.
CAUTION
Do not autoclave any part of the unit or its accessories.
8
3 Regulatory Limitations of Use
Declaration of Conformity
This product fulfils the essential requirements of the Low Voltage Directive (LVD) 2006/95/EC and the EMC Directive 2004/108/EC, when installed and operated in accordance with the instructions in this manual.
The Microplate Heat Sealer unit has been type tested by EMC Projects Limited (UKAS and CAA approved test facility and UK appointed Notified Body) against the EMC Requirements listed below, and issued Certificate No TES-001122-01.
Safety and EMC Requirements
SAFETY
EN 61010-1:2010, EN 61010-2-051:2003
UL 61010-1:2001 2nd Edition (CAN C22.2 CSA 61010-1)
EMC
EN 61326:2006, Class B
FCC CFR 47 Parts 15.107 and 15.109, Class B
WEEE Directive Compliance
WEEE
Where applicable, the Microplate Heat Sealer unit should be disposed of in accordance with the European Union WEEE Directive 2002/96/EC on Waste Electrical and Electronic Equipment.
Do not dispose of this product into unsorted municipal waste or public landfill. Please refer to section 7.6 for details of how to correctly dispose of this product.
The Microplate Heat Sealer unit is designed and manufactured under ISO 9001 by:
Integrated Technologies Limited Viking House, Ellingham Way, Ashford, Kent, TN23 6NF United Kingdom