PCE Instruments PCE-WS A, PCE-WS V Users guide

Page 1
Anemometers
English
PCE-WS V 0-10V OU
TPUT
PCE-WS A 4-20mA OU
PCE-WS V/A range of PCE Instruments
Wind Speed sensor designed for di󰀨erent industries and sector
Last change: 07 November 2019 v1.0 English
© PCE Instruments
Industrial design for extreme environments
Analogue output (4-20mA or 0-10 V)
Stainless Steel bearings
Low consumption
Made in Spain
TPUT
Page 2
APPLICATIONS
PCE-WS V/A has been designed for industrial applications: cranes, solar panels, wind turbines, weather stations… It is usually connected to devices such as displays (see our references PCE-WSAC 50 series or PCE-DPD-U), PLCs or dataloggers to display the wind speed and/or set alarms
to predened values or to obtain records during predened
periods of time.
The wind sensor must be xed on a vertical position.
WIND SPEED - OUTPUT RATIO
4…20 mA = 0…180 km/h
DIMENSIONS
50
PCE-WS V/A CABLE
139
131
91
10
Ø123
5
Ø
Analogue output [mA]
0...10 V= 0…180 km/h
Analogue output [V]
Wind speed [km/h]
Wind speed [km/h]
PCE-WS V/A M8 LATERAL
27
PCE-WS V/A OUTPUT
Page 3
TECHNICAL FEATURES
4-20 mA OUTPUT Electrical features
Power supply 12…30 Vdc
Maximum current <20 mA
Type of output Analogue (4-20 mA, 2 wires)
Maximum connectable
impedance
<
L
VCC — 8V
0.02 A
ΩR
0-10 V OUTPUT Electrical features
Power supply 15-24 Vdc
Power consumption <2.5 W
Type of output Analogue (0-10 V)
Minimum connectable
4k6 Ω
impedance
Measurements
Range 3-180 km/h*
Starting speed 8 km/h
Survival speed 200 km/h
Accuracy 1km/h (3-15 km/h)
3% (15-180 km/h)*
*Depending on version
General features
Material PA + FV
Bearings Stainless steel X65Cr13
Type of connection See references
Weight (with a 20m cable) 1425 g
Weight (without cable) 135 g
Dimensions 125x139 mm
Storage temperature -35ºC +80ºC
Working temperature -20ºC +70ºC
EMC EN 61000-6-2:2001
EN 55022:2001, Class B
Protection IP65 (UNE 20324:1993)
CONNECTION
PCE-WS A 4-20mA OUTPUT PCE-WS V 0-10 V OUTPUT
PIN2 YELLOW
PIN4 BLACK
PIN3 NC
PIN1 RED
Vcc (12-30 Vdc)
Analog Input (4-20mA)
RL
PLC ground
Vcc (15-24 Vdc)
Analog Input (0-10 Vdc)
RL (>4k6 Ohm)
PLC ground
© PCE Instruments
Page 4
REFERENCES AND VERSIONS
References
4-20mA OUTPUT
PCE-WS A Anemometer 4-20mA Output 180 km/h 20m
Cable
PCE-WS A/ M8L*
Anemometer 4-20mA Output 180 km/h M8 Lateral
0-10V OUTPUT
PCE-WS V Anemometer 0-10V Output 180 km/h 20m
Cable
Other devices of PCE-WS range
Heated 4-20 mA
PCE-WS AH/ M12*
Anemometer 4-20mA Output 180km/h M12 Underside. Heated version. Female connector included.
Displays
PCE-WSAC 50 series
Range of anemometer wall mount displays
with 2 relay alarms. Di󰀨erent versions
available depending on: type of input (0-10V or 4-20mA, optional RS485, power input (110Vac 60Hz, 220Vac 50Hz or 24Vdc) and m/s or mph indication
PCE-DPD-U Panel display 96x48 IP65 with universal
power input and optional output modules (relay, RS485, etc.)
*Check availability and MOQ
Accessories
PCE-WS/ MOUNT
65
Ø27
7,5
50
Optional mounting kit for PCE-WS anemometers & PCE-WV wind vanes
190
Ø5
22,5
54
10
25
Ø7
70
54
Ø8
Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU devices must be properly disposed of in accordance with this regulation, we give them to a recycling company which disposes of the devices in line with law. For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments.
Contact information for each country and user manuals in various languages can be found on our website: www.pce-instruments.com
All dimensions and sizes are approximate. Specications and prices are subject to change without notice.